1、 FORD LABORATORY TEST METHOD BO 150-02 Date Action Revisions 2001 04 02 Revised Editorial no technical change A. Cockman 1991 06 10 Printed copies are uncontrolled Page 1 of 6 Copyright 2001, Ford Global Technologies, Inc. RESISTANCE OF TEXTILES TO ACCELERATED AGEING BY XENON ARC Application This me
2、thod is used to determine the resistance of textiles to fade and degradation when exposed to high intensity Xenon arc radiation. Apparatus Required Xenotest 1200 U Source: Heraeus Equipment Ltd. or W.C. Heraeus GmbH Unit 9 Wates Way Instrumental Division Brentwood OH Department Essex CM15 9TB Postfa
3、ch 1553 D-6450 Hanau 1 Germany Grey Scale - for Evaluation of Change of Colour Source: for ISO - recommendation R 105/1 scale Beuth-Verlag GmbH Postfach 1145 D-1000 Berlin 30 Germany for AATCC Scale Evaluation Procedure 1 American Association of Textile Chemists and Colourists P.O. Box 12215 Researc
4、h Triangle Park NC 37709 U.S.A. AATCC L2 and L4 Blue Wools for Equipment Calibration Source: Same address as stated for AATCC Grey Scale. FORD LABORATORY TEST METHOD BO 150-02 Page 2 of 6 Copyright 2001, Ford Global Technologies, Inc. Color Matching Device (North Sky Daylight) As described in FLTM B
5、I 109-01 Source: Multilight Ltd. or Dr. A. Th. Bruck Kennet Side 5 Koln - Holweide Newbury Dabringhauser Strasse 48 Berkshire RG14 5TE Germany England Tensile Testing Machine Constant rate of traverse with recording device. Stoll Abrasion Tester As described in FLTM BN 108-01. Spectrophotometer ICS
6、Texicon MM 9000 or equivalent. Source: Instrumental Colour Systems Ltd. Kennetside Park Industrial Estate Newbury Berkshire RG14 5TE England Instruments used to determine color difference require capability for providing CIELAB color values utilizing illuminant D-65, 10 observer data. If an instrume
7、nt with diffuse geometry is used, the specular component of reflectance shall be included in the measurement. Note: An aperture diameter smaller than 20 mm should not be used for these measurements. Operating Conditions - Xenotest 1200 The machine is fitted with 3 x 4.5 KW Xenon burners, 64 cm long
8、surrounded by a quartz cylinder and water cooling jacket. The effective life of the burners is 1500 hours. One new burner is fitted every 500 hours to minimize variations in radiation intensity. The radiation intensity in the wavelength range of 300 - 830 nm is approximately 1000 W/m2. (The radiatio
9、n intensity and spectral energy distribution can be varied by fitting UV-filters or window glass.) A revolving specimen rack is fitted which carries 25 specimen holders (630 x 70 mm in size) at a distance of 265 mm from the axis of the Xenon burners. Wider specimen holders (630 x 150 mm in size) can
10、 be made and fitted in place of 2 small holders to support the larger specimens required for certain tests. FORD LABORATORY TEST METHOD BO 150-02 Page 3 of 6 Copyright 2001, Ford Global Technologies, Inc. Specimen Temperature This is controlled by adjusting the test chamber temperature and checked b
11、y means of a black panel thermometer mounted on a specimen holder. Test Chamber Temperature This can be regulated by (and is indicated on) the remote thermometer on the control panel at the front of the machine. Test Chamber Relative Humidity This can be regulated by (and is indicated on) the remote
12、 humidity controller at the front of the machine. Water Spray There is also a facility for spraying the specimens with water at pre-determined intervals to simulate rain in outdoor exposures. Laboratory Environment In order to maintain controlled conditions in the equipment, it should be operated in
13、 a dust free environment with the temperature controlled between 15 and 25 C. Standard Test Conditions Unless different conditions are quoted in the Material Specification, the following standard settings shall apply to all Xenotest exposures described by this method: Black panel temperature (B P) 7
14、5 +/- 3 C Test chamber temperature (T C) 50 +/- 1 C Relative humidity (R H) 80 +/- 5 % UV or window glass filters Not required Water spray on specimens Not required In addition, the equipment must be installed, operated and maintained in line with the Manufacturers recommendations. To ensure uniform
15、ity of testing the following should be observed: To prevent peak irradiance after installation of new burners, burners should be supplied pre-aged. To ensure equivalence of irradiance exposure the top and bottom 100 mm of the specimen holder should not be utilized. Top and bottom reflectors should b
16、e cleaned (at least every 48 hours and polished with a good quality non-abrasive liquid cleaning agent). FORD LABORATORY TEST METHOD BO 150-02 Page 4 of 6 Copyright 2001, Ford Global Technologies, Inc. The central glass column should be cleaned on the outside at the same time. Ensure that the distil
17、led water tanks are kept clean. The waste water should not be recirculated unless it is demineralized again. Radiation checks with a Radialux UV Sensor (top, middle and bottom of the rack) should be made before and after each service. Value to be within 116 W/m2 /second +/- 4. Calibration checks uti
18、lizing AATCC L2 and L4 blue wools should be made adopting the following procedure. Calibration Procedure This procedure describes the use of AATCC blue wool lightfastness standards as reference fabrics for the purpose of determining whether the xenon arc apparatus is operating within the specified l
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDFLTMBO15022001RESISTANCEOFTEXTILESTOACCELERATEDAGEINGBYXENONARCREPLACESFLTMEUBO05002PDF

链接地址:http://www.mydoc123.com/p-747381.html