FORD FLTM BI 112-02-2001 TUKON HARDNESS OF PAINT (Replaces FLTM BI 012-02 FLTM EU-BI 012-02)《油漆的图康(TUKON)硬度 替代FLTM BI 012-02 FLTM EU-BI 012-02[替代 FORD FLTM BI 012-02 FORD FLTM EU-B.pdf
《FORD FLTM BI 112-02-2001 TUKON HARDNESS OF PAINT (Replaces FLTM BI 012-02 FLTM EU-BI 012-02)《油漆的图康(TUKON)硬度 替代FLTM BI 012-02 FLTM EU-BI 012-02[替代 FORD FLTM BI 012-02 FORD FLTM EU-B.pdf》由会员分享,可在线阅读,更多相关《FORD FLTM BI 112-02-2001 TUKON HARDNESS OF PAINT (Replaces FLTM BI 012-02 FLTM EU-BI 012-02)《油漆的图康(TUKON)硬度 替代FLTM BI 012-02 FLTM EU-BI 012-02[替代 FORD FLTM BI 012-02 FORD FLTM EU-B.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、 FORD LABORATORY TEST METHOD BI 112-02 Date Action Revisions 2001 03 19 Revised Editorial no technical change A. Cockman 1990 02 12 Printed copies are uncontrolled Page 1 of 2 Copyright 2001, Ford Global Technologies, Inc. TUKON HARDNESS OF PAINT Application This method is used to determine the micr
2、ohardness of paint and is performed by indenting the paint film with a standard Knoop indenter by application of a 25 g load. Apparatus Required Microhardness Tester Tukon Models 200 and 300, or equivalent. Source: Rockwell Hardness Testers Sandy Lane Stourport-on-Severn Worcestershire, DY133QA, Eng
3、land or Wilson Instrument Division of SPM Corp. P.O. Box 3006, 20 Commerce Park Milford, Connecticut 06460 U.S.A. Paint Thickness Tester Refer to FLTM BI 117-01, Thickness Measurement of Paint Films. Conditioning and Test Conditions All test values indicated herein are based on material conditioned
4、in a controlled atmosphere of 23 +/- 2 C and 50 +/- 5 % relative humidity for not less than 24 h prior to testing and tested under the same conditions unless otherwise specified. Procedure 1. Prepare the panel as described in the applicable Engineering Material Specification. Note: Minimum dry film
5、thickness 35 microns. FORD LABORATORY TEST METHOD BI 112-02 Page 2 of 2 Copyright 2001, Ford Global Technologies, Inc. 2. After preparation, condition the panel as required by the applicable Engineering Materials Specification. If not specified in the Engineering Material Specification, condition th
6、e panel for 24 h minimum a 23 +/- 2 C and 50 +/- 5 % relative humidity and immediately test the panel. 3. On the area of the panel that is to be used for hardness tests, film thickness determinations must be made (FLTM BI 117-01) to ensure that film thickness on any one panel does not vary more than
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDFLTMBI112022001TUKONHARDNESSOFPAINTREPLACESFLTMBI01202FLTMEUBI01202 油漆 TUKON 硬度 替代 FLTMBI01202FLTMEUBI01202

链接地址:http://www.mydoc123.com/p-746989.html