DLA A-A-50492 A-1993 OILERS AIR LINE《空气管加油器》.pdf
《DLA A-A-50492 A-1993 OILERS AIR LINE《空气管加油器》.pdf》由会员分享,可在线阅读,更多相关《DLA A-A-50492 A-1993 OILERS AIR LINE《空气管加油器》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、. A-A-50492A = 9999974 OL562L2 4T5 I INCH-POUND I A-A-50492A November 29. 1993 SUPERSEDING 28 February 1989 A-A- 50492 COMMERCIAL ITEM DESCRIPTION OILERS, AIR LINE This Commercial Item Description is approved by the Commissioner, Federal Supply Service, General Services Administration, for the use o
2、f all Federal agencies. to Military Specification MIL-0-82042, which is cancelled. This CID is to be used in preference 1. Abstract. This CID covers the requirements for air line oilers. Configuration of the oiler shall be type I, lubricator, filter, pressure regulator, and gauge, 1/2-inch (12.7-mil
3、limeters (nun) internal pipe thread connection, similar to figure 1; or type II, lubricator and filter, 1/4-inch (6.35 nun) internal pipe thread connection, similar to figure 2. Type I oiler is commonly referred to as a filter-regulator-lubricator on the commercial market. The oiler is to be used wi
4、th air-powered tool and air-powered mechanisms in compressed air systems. 2. Salient characteristics. 2.1 TvDe I oiler performance. The type I oiler shall remove at least 90 percent of the condensed water, and 95 percent of 50 microns or larger size foreign particles from an air line delivering up t
5、o 70 standard cubic feet per 100 pounds per square inch gage (psig) (689 kilopascals (kPa). The oiler shall also regulate the air pressure between 10 and 125 psig (69 and 862 kPa) while dispensing a constant, adequate supply of lubricant to the discharge air in the air supply system. minute (scfm) (
6、0.03 cubic meters per second (m 3 /SI) at an inlet pressure of IBeneficial comments (recommendations, additions, deletions) and any pertinent1 Idata which may be of use in improving this document should be addressed to: I 11000 23rd Avenue. Port Hueneme. CA 93043-4301. Iconmanding Officer (Code 156)
7、, Naval Construction Battalion Center, I I FSC 4930 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-50492A 2.2 Type i1 oiler performance. ?he type II oiler shall re
8、move at least 90 percent of the condensed water and 95 percent of 50 microns or larger size fc eign particles from an air line delivering up to 20 scfm (0.01 m /s) at an iniet pressure of 100 psig (689 kPa). Type II oiler shall function in an air slipply between 10 and 125 psig (69 and 862 kPa) ,nd
9、dispense a constant adequate supply of lubricant to the discharge air in the air supply system. 3 2.3 Lubricator. type I and type II. The lubricator shall have a body, bowl, sight dome or sight glass, adjustable oil feed, filler plug, gaskets, and other necessary components. The bowl shall be metal
10、or plastic and shall be provided with !owl guards, if plastic. Lubricators with metal bowls shall withstand a presqure of 250 psig (1724 kPa) at a temperature of 100 degrees Fahrenheit (OF) (37: degrees Celsius (OC). Lubricators with plas.tic bowls shall withstand a pre sure of 150 psig (1036 kPa) a
11、t a temperature of 100F (37.7OC). The sight glass shall be readily replaceable and constructed of a shatter-resistant material. A filler plug, provided with means for bleeding off pressure inside the oil chamber before removal of the plug, shall be readily accessible for refilling. A metering valve
12、shall be furnished to accomplish adjustment of the oil feed rate from a flow of one drop per minute to maximum flow. The valve shall not change its setting as a result of jars or vibrations. The lubricator shall function under continuous or intermittent operation and shall not cause flooding of oil
13、into the air line. The amount of atomized oil injected into the air shall be proportional to the amount of air flowing through the system. When specified, the lubricator shall be so constructed that refilling of the reservoir can be accomplished without shutting off the air supply. 2.4 Lubricator ca
14、pacity. Type I lubricator shall have a capacity of not less than 7 fluid ounces (207 milliliters (mL); type II lubricator shall have a capacity of not less than 4 fluid ounces (118 mL). 2.5 Lubricator maximum pressure drov. Type I lubricator shall have a maximum pressure drop of 6 pounds per square
15、inch psi) (41 kPa) at an inlet have a maximum pressure drop of 6 psi (41 kPa) at an inlet pressure of 100 psig (689 kPa) and 20 scfm (0.01 m3/s). pressure of 100 psig (689 kPa) and 70 scfm (0.03 m I /s); type II lubricator shall 2.6 Lubricator verformance. The lubricator shall operate using oil with
16、 a viscosity up to 800 Saybolt Universal Seconds equivalent to CAE 30W oil at a temperature not less than 85OF (3OOC). 2.7 Filter. type I and type II. The filter shall have a body, transparent bowl, filter element, drain, gaskets, and other necessary components. The bowl shall be readily removable w
17、ithout the use of tools and constructed of metal or a shatter-resistant plastic, such as polycarbonate resin. A drain shall be provided to allow liquids and foreign matter to be drained from the bowl. The drain shall be of the manual type. The drain shall be so constructed that it cannot be disassem
18、bled when opened for drainage purposes. filter shall be such that liquids and foreign matter (dirt, rust, scale) will be separated from the compressed air stream and prevented from making contact with the filter element. The filter elements shall be porous plastic, or porous bronze, or impregnated f
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAAA50492A1993OILERSAIRLINE 气管 加油 PDF