1、 FORD LABORATORY TEST METHOD AN 105-01 Date Action Revisions 2001 01 30 Revised Editorial no technical change A. Cockman 2000 04 17 Editorial no technical change A. Cockman 1994 09 26 Printed copies are uncontrolled Page 1 of 4 Copyright 2001, Ford Global Technologies, Inc. DETERMINATION OF FINISH C
2、ONTENT OF SEWING THREAD Application This procedure is used to determine the percent by weight of finish on sewing threads. Materials and Apparatus Required Extraction Apparatus Solvent Extraction Apparatus (Soxhlet type) incorporating a reflux condenser and a 250 mL glass flask and suitable filter t
3、himbles. Support Rods and Clamps - for holding extraction apparatus. Hot Plate With adjustable temperature control. Drying Oven Capable of maintaining a constant temperature of 105 +/- 2 C. Analytical Balance Having a sensitivity of +/- 0.1 mg Desiccator Charged with calcium chloride. Weighing Bottl
4、es Ethyl Ether Denatured Ethyl Alcohol Conditioning and Test Conditions All test values indicated herein are based on material conditioned in a controlled atmosphere of 23 +/- 2 C and 50 +/- 5 % relative humidity for not less than 24 h prior to testing and tested under the same conditions unless oth
5、erwise specified. FORD LABORATORY TEST METHOD AN 105-01 Page 2 of 4 Copyright 2001, Ford Global Technologies, Inc. Procedure 1. Clean and dry a weighing bottle and cover in an oven for 15 minutes at 105 +/- 2 C. 2. Remove the bottle from the oven, place immediately in a desiccator, uncovering the li
6、d of the weighing bottle and allow to cool to 23 +/- 2 C. 3. Cover and weigh to the nearest milligram to obtain the dry weight of bottle and cover (A). 4. Transfer approximately 5 grams of the thread specimen to the tared weighing bottle and dry (uncovered) in the oven for 2 h at 105 +/- 2 C. 5. Rem
7、ove the bottle from the oven, place immediately in a desiccator (uncovering the lid of the weighing bottle) and allow to cool to 23 +/- 2 C (for approximately 30 minutes). Cover and weigh to the nearest milligram to obtain the dry weight of bottle, cover, and thread (B). 6. Calculate initial dry wei
8、ght of thread - W1 W1 = B - A where A = Dry weight of bottle and cover where B = Dry weight of bottle and cover and thread where W1 = Dry weight of thread 7. Insert the test specimen into a filter thimble and place into the Soxhlet extractor, add 150 mL ethyl ether to the flask and assemble the appa
9、ratus for extraction. 8. Adjust the temperature of the hot plate to maintain moderate boiling of the solvent. Reflux until the extractor has completely filled and emptied 16 20 times (3 - 4 h). 9. Disassemble the apparatus, transfer the test specimen to the tared weighing bottle and dry in an oven f
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDFLTMAN10512001DETERMINATIONOFFINISHCONTENTOFSEWINGTHREADREPLACESFLTMEUAN00501PDF

链接地址:http://www.mydoc123.com/p-746808.html