FORD ESB-M1L120-A-2003 CABLE PRIMARY LOW TENSION 85 VINYL INSULATED - REDUCED WALL THICKNESS TO BE USED WITH FORD WSS-M99P1111-A 《乙烯基塑料绝缘的(小壁厚度)85℃PRIMARY低压电缆 与标准FORD WSS-M99P11.pdf
《FORD ESB-M1L120-A-2003 CABLE PRIMARY LOW TENSION 85 VINYL INSULATED - REDUCED WALL THICKNESS TO BE USED WITH FORD WSS-M99P1111-A 《乙烯基塑料绝缘的(小壁厚度)85℃PRIMARY低压电缆 与标准FORD WSS-M99P11.pdf》由会员分享,可在线阅读,更多相关《FORD ESB-M1L120-A-2003 CABLE PRIMARY LOW TENSION 85 VINYL INSULATED - REDUCED WALL THICKNESS TO BE USED WITH FORD WSS-M99P1111-A 《乙烯基塑料绝缘的(小壁厚度)85℃PRIMARY低压电缆 与标准FORD WSS-M99P11.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、 ENGINEERING MATERIAL SPECIFICATIONDate Action Revisions 2003 06 25 Revised Para 3.0 inserted; Para 3.1, 3.5, & 4 deleted 1986 02 03 CAQ1-DR532891 Released Printed copies are uncontrolled Copyright 2003, Ford Global Technologies, Inc. Page 1 of 5 CABLE, PRIMARY LOW TENSION, 85 C ESB-M1L120-A VINYL I
2、NSULATED - REDUCED WALL THICKNESS 1. SCOPE The material defined by this specification is a low tension stranded cable, vinyl-insulated with non-coated conductor. The cable is similar to SAE J 1128 Type GPT (General Purpose - Thermoplastic Insulated) but with a reduced insulation wall thickness, and
3、an 85 C classification. 2. APPLICATION This specification was released originally for material used in automotive electrical harnesses. Note: The assemblers of electrical wire harnesses shall use the bulk wire suppliers as shown in the Ford Motor Company Materials Approved Source List. 3. REQUIREMEN
4、TS 3.0 STANDARD REQUIREMENTS FOR PRODUCTION MATERIALS Material suppliers and part producers must conform to the Companys Standard Requirements For Production Materials (WSS-M99P1111-A). 3.2 CONDUCTOR 3.2.1 The individual strands of the conductor shall be soft or annealed copper conforming to ASTM B
5、3 - 1974, except strand dimensions. These dimensions shall be controlled to yield the cross-sectional area listed for the conductor of the finished cable per Table 1. Conductor area shall be determined by measuring individual strand diameters and calculating the sum of the individual strand areas. A
6、s an alternate method, conductor area may also be determined in accordance with ASTM B 263 - 1958. 3.2.2 The strands shall be bunched per ASTM B 174 - 1971. The maximum lay length shall be as specified in ASTM B 174 - 1971 Table 2, Column A. Conductor strand count shall comply with Table 1. Missing
7、strands are not allowed. 3.3 INSULATION 3.3.1 The color of the vinyl insulation shall be specified on the engineering drawing of the component utilizing this material. Base and stripe color codes shall correspond to SAE J 1128. Where striping is specified, the stripe shall be a minimum of 0.5 mm wid
8、e, but not more than 19% of the circumference of the wire. The stripe shall be of the same material as the vinyl insulation. 3.3.2 The insulating material shall be a polyvinyl chloride (PVC) material, homogeneous in character, and similar to SAE J 1128 Type GPT. The material shall adhere closely to,
9、 but strip readily from the conductors, leaving them free of insulation and in suitable condition for applying terminals. ENGINEERING MATERIAL SPECIFICATIONESB-M1L120-APrinted copies are uncontrolled Copyright 2003, Ford Global Technologies, Inc. Page 2 of 5 3.3.3 Insulation thickness shall comply w
10、ith the requirements of Table 2. Insulation thickness shall be measured in accordance with ANSI/UL-1581-1985, Reference Standard for Electrical Wires, Cables, and Flexible Cords, Paragraphs 240. through 250.11. A 0.51 mm diameter pin will be used for determining minimum insulation thickness at any p
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDESBM1L120A2003CABLEPRIMARYLOWTENSION85VINYLINSULATEDREDUCEDWALLTHICKNESSTOBEUSEDWITHFORDWSSM99P1111A

链接地址:http://www.mydoc123.com/p-745188.html