ETSI EN 302 536-2-2007 Electromagnetic compatibility and Radio spectrum Matters (ERM) Short Range Devices (SRD) Radio equipment in the frequency range 315 kHz to 600 kHz Part 2 Har_1.pdf
《ETSI EN 302 536-2-2007 Electromagnetic compatibility and Radio spectrum Matters (ERM) Short Range Devices (SRD) Radio equipment in the frequency range 315 kHz to 600 kHz Part 2 Har_1.pdf》由会员分享,可在线阅读,更多相关《ETSI EN 302 536-2-2007 Electromagnetic compatibility and Radio spectrum Matters (ERM) Short Range Devices (SRD) Radio equipment in the frequency range 315 kHz to 600 kHz Part 2 Har_1.pdf(16页珍藏版)》请在麦多课文档分享上搜索。
1、 ETSI EN 302 536-2 V1.1.1 (2007-11)Harmonized European Standard (Telecommunications series) Electromagnetic compatibilityand Radio spectrum Matters (ERM);Short Range Devices (SRD);Radio equipment in the frequency range 315 kHz to 600 kHz;Part 2: Harmonized EN covering essential requirementsof articl
2、e 3.2 of the R Essential, or potentially Essential, IPRs notified to ETSI in respect of ETSI standards“, which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web server (http:/webapp.etsi.org/IPR/home.asp). Pursuant to the ETSI IPR Policy, no investigation, includin
3、g IPR searches, has been carried out by ETSI. No guarantee can be given as to the existence of other IPRs not referenced in ETSI SR 000 314 (or the updates on the ETSI Web server) which are, or may be, or may become, essential to the present document. Foreword This Harmonized European Standard (Tele
4、communications series) has been produced by ETSI Technical Committee Electromagnetic compatibility and Radio spectrum Matters (ERM). The present document has been produced by ETSI in response to a mandate from the European Commission issued under Council Directive 98/34/EC (as amended) laying down a
5、 procedure for the provision of information in the field of technical standards and regulations. The present document is intended to become a Harmonized Standard, the reference of which will be published in the Official Journal of the European Communities referencing the Directive 1999/5/EC of the E
6、uropean Parliament and of the Council of 9 March 1999 on radio equipment and telecommunications terminal equipment and the mutual recognition of their conformity (“the R Part 2: “Harmonized EN covering essential requirements of article 3.2 of the R Short Range Devices (SRD); Radio equipment in the f
7、requency range 315 kHz to 600 kHz; Part 1: Technical characteristics and test methods“. 2 ETSI TR 100 028 (V1.4.1) (all parts): “Electromagnetic compatibility and Radio Spectrum Matters (ERM); Uncertainties in the measurement of mobile radio equipment characteristics“. 3 Definitions, symbols and abb
8、reviations 3.1 Definitions For the purposes of the present document, the terms and definitions given in the R the value of the measurement uncertainty for the measurement of each parameter shall be included in the test report; the recorded value of the measurement uncertainty shall be, for each meas
9、urement, equal to or lower than the figures in table 1. For the test methods, according to the present document, the measurement uncertainty figures shall be calculated in accordance with TR 100 028 2 and shall correspond to an expansion factor (coverage factor) k = 1,96 or k = 2 (which provide conf
10、idence levels of respectively 95 % and 95,45 % in the case where the distributions characterizing the actual measurement uncertainties are normal (Gaussian). Table 1 is based on such expansion factors. Table 1: Maximum measurement uncertainty Radio frequency 1 10-7RF power, conducted 0,75 dB RF powe
11、r, radiated 6 dB Temperature 1C Humidity 5 % Voltage 1 % 5.3 Essential radio test suites 5.3.1 Permitted frequency range of the modulation bandwidth The test for bandwidth specified in EN 302 536-1 1, clause 8.3.2 appropriate to the EUT shall be carried out. The results obtained shall be compared to
12、 the limits in clause 4.2.2.2 in order to assess compliance with the requirement. ETSI ETSI EN 302 536-2 V1.1.1 (2007-11) 105.3.2 Effective radiated field strength of the fundamental emission The test for radiated magnetic field strength of the fundamental emission specified in EN 302 536-1 1, claus
13、e 8.2.1.2 and for radiated electric field strength specified in EN 302 536-1 1, clause 8.2.2.2, appropriate to the EUT shall be carried out. The results obtained shall be compared to the H-field limit in clause 4.2.3.1.2 and the E-field limit in clause 4.2.3.2.2 in order to assess compliance with th
14、e requirement. 5.3.3 Spurious emissions The test for spurious emissions specified in EN 302 536-1 1, clause 8.4.2.1 appropriate to the EUT shall be carried out. The results obtained shall be compared to the limits in clause 4.2.4.3 in order to assess compliance with the requirement. 5.3.4 Spurious r
15、adiation of receivers The test for spurious radiation of receivers specified in EN 302 536-1 1, clause 9.1.2 appropriate to the EUT shall be carried out. The results obtained shall be compared to the limits in clause 4.2.5.2 in order to assess compliance with the requirement. 5.3.5 Normal and extrem
16、e test-conditions The test conditions shall be as declared by the manufacturer. The requirements and test procedures shall be as specified in EN 302 536-1 1, clauses 5.3 and 5.4. 5.3.6 Test power source The test power source shall meet the requirements of EN 302 536-1 1, clause 5.2 as applicable. 5.
17、3.7 Choice of samples for test suites Measurement shall be performed, according to the present document, on samples of equipment defined in EN 302 536-1 1, clause 4.2. ETSI ETSI EN 302 536-2 V1.1.1 (2007-11) 11Annex A (normative): HS Requirements and conformance Test specifications Table (HS-RTT) Th
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ETSIEN30253622007ELECTROMAGNETICCOMPATIBILITYANDRADIOSPECTRUMMATTERSERMSHORTRANGEDEVICESSRDRADIOEQUIPMENTINTHEFREQUENCYRANGE315KHZTO600KHZPART2HAR_1PDF

链接地址:http://www.mydoc123.com/p-730352.html