《EN 61205-1994 en Ultrasonics - Dental Descaler Systems Measurement and Declaration of the Output Characteristics《超声波 牙齿除垢装置 产品性能说明及测试(IEC 1205-1993)》.pdf》由会员分享,可在线阅读,更多相关《EN 61205-1994 en Ultrasonics - Dental Descaler Systems Measurement and Declaration of the Output Characteristics《超声波 牙齿除垢装置 产品性能说明及测试(IEC 1205-1993)》.pdf(17页珍藏版)》请在麦多课文档分享上搜索。
1、EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM H 3404583 0100427 300 = EN 61205 January 1994 UDC 615.47 : 616.314 Descriptors: Ultrasound, dental descaler, output characteristics, measurement English version Ultrasonics - Dental descaler systems Measurement and declaration of the output character
2、istics (IEC 1205 : 1993) Ultrasons - Systmes de dtartreurs dentaires - Mesure et dclaration des caractristiques de sortie (CE1 1205 : 1993) Ultraschall - Zahnreinigersysteme Messung und Deklaration der Ausganskennwerte (IEC 1205 : 1993) This European Standard was approved by CENELEC on 1993-12-08. C
3、ENELEC members are bound to comply with the CENICENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained o
4、n application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Se
5、cretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom. CENE
6、LEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B-1050 Brussels O 1994 Copyright reserved to CENELEC members Ref. No. EN 61205 : 1994 E = 3404583 0300
7、428 247 Page 2 EN 61205 : 1994 Foreword The text of document 87(C0)26, as prepared by IEC Technical Committee 87: Ultrasonics, was submitted to the IEC-CENELEC parallel vote in March 1993. The reference document was approved by CENELEC as EN 61205 on 8 December 1993. The following dates were fixed:
8、- latest date of publication of an identical national standard (dop) 1994-12-01 - latest date of withdrawal of conflicting national standards (dow) 1994-12-01 Annexes designated normative are part of the body of the standard, Annexes designated informative are given only for information. In this sta
9、ndard, annexes A and B are informative and annex ZA is normative. 3404583 0300429 383 Page 3 EN 61205 : 1994 CONTENTS Page INTRODUCTION 4 Clause Scope 5 Normative reference 5 Definitions of output characteristics 5 List of symbols 6 General measuring conditions . 6 5.1 Operating conditions 6 5.2 Loa
10、d conditions 6 5.3 Cleaning of the apparatus . 6 5.4 Irrigant temperature . 6 Measurement procedures . 6 6.1 Primary tip vibration excursion . 6 6.2 Tip vibration frequency 7 6.3 Half-excursion force 8 8 Requirements for the declaration of essential output characteristics . Annexes A General informa
11、tion about ultrasonic dental descalers (scalers) . 9 B Guidance on the measurement methods . 13 Figures . 15 Bibliography . 12 Annex ZA (normative) Other international publications quoted in this standard with the references of the relevant European publications 17 M 3404583 0100430 T5 Page 4 EN 612
12、05 : 1994 INTRO DU CTIO N Ultrasonic dental descalers are widely used for removing plaque and calculus from teeth. Although the mode of action of these devices has not been well characterized, the cleaning efficiency of ultrasonic dental descalers depends on the vibration amplitude. The purpose of t
13、his International Standard is to define standard methods of measurement and specification of the essential vibration characteristics of ultrasonic dental descalers. Questions of safety and biological effects of the output are not treated in this standard. 3404583 OLO043L 831 Page 5 EN 61205 : 1994 U
14、LTRASONICS - DENTAL DESCALER SYSTEMS - Measurement and declaration of the output characteristics 1 Scope This International Standard specifies: - essential non-thermal output characteristics of ultrasonic dental descalers; - methods of measurement of the output performance of ultrasonic dental desca
15、lers; - characteristics to be declared by the manufacturers of ultrasonic dental descalers. 2 Normative reference The following normative reference contains provisions which, through reference in this text, constitute provisions of this International Standard. At the time of publication, the edition
16、s indicated were valid. All normative documents are subject to revision, and patties to agreements based on this International Standard are encouraged to investigate the possibility of applying the most recent edition of the normative document listed below. Members of IEC and IS0 maintain registers
17、of currently valid International Standards. I EC 782: 1984, Measurements of ultrasonic magnetostrictive transducers 3 Definitions of output characteristics For the purposes of this International Standard, the following definitions apply. 3.1 half-excursion force: Force with which the tip must contac
18、t a glass slide so as to reduce the primary tip vibration excursion to 50 % of the value it has when the contact force is 0,15 N I0,02 N. 3.2 primary tip vibration excursion: Peak-to-peak displacement of the applicator in the direction of maximum amplitude, at a point on the applicator not more than
19、 1 mm from its tip. 3.3 tip vibration frequency: Fundamental frequency at which the tip of the applicator oscillates. m 3404583 0300432 778 m Page 6 EN 61205 : 1994 4 List of symbols s Primary tip Vibration excursion. Wo Width of score marks on a glass slide with power off. Wp Width of score marks o
20、n a glass slide with power on. 5 General measurlng conditions 5.1 Operating conditions Measurements shall be performed under parameters set to values recommended by the manufacturer. The parameters to be considered are: - ambient temperature: - probe tip irrigant flow; - driving frequency; - output
21、amplitude; - warm-up time. Prior to making measurements, all controls associated with the ultrasonic dental descaler shall be set to produce maximum vibration excursion. 5.2 Load conditions Measurements shall be made with the applicator tip contacting a glass microscope slide. The slide shall be lub
22、ricated with water (tap water is sufficient) and the standard contact force shall be 0,15 N f 0.02 N. For the purposes of the half-excursion force measure- ment (see 6.3). the method of applying the load shall be such that the load can be gradually increased. To ensure accuracy of the measurement, t
23、he motion of the tip shall be essentially perpendicular to the load. The force at the tip shall be known or measured. 5.3 Cleaning of the apparatus All surfaces and parts of the applicator and of the measurement devices which come into contact with water shall be cleaned, rinsed with warm water and
24、dried in air. 5.4 Irrigant temperature The irrigant shall emerge at a temperature between 30 OC and 40 OC or at the temperature specified by the manufacturer (see clause 7). 6 Measurement procedures 6.1 Primary tip vibration excursion One of the following methods shall be used for measuring the prim
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN612051994ENULTRASONICSDENTALDESCALERSYSTEMSMEASUREMENTANDDECLARATIONOFTHEOUTPUTCHARACTERISTICS 超声波

链接地址:http://www.mydoc123.com/p-719765.html