EN 61161-2007 en Ultrasonics - Power measurement - Radiation force balances and performance requirements (Remains Current)《超声波 功率测量 辐射力平衡和性能要求》.pdf
《EN 61161-2007 en Ultrasonics - Power measurement - Radiation force balances and performance requirements (Remains Current)《超声波 功率测量 辐射力平衡和性能要求》.pdf》由会员分享,可在线阅读,更多相关《EN 61161-2007 en Ultrasonics - Power measurement - Radiation force balances and performance requirements (Remains Current)《超声波 功率测量 辐射力平衡和性能要求》.pdf(52页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARDBS EN 61161:2007Ultrasonics Power measurement Radiation force balances and performance requirementsThe European Standard EN 61161:2007 has the status of a British StandardICS 17.140.50g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40
2、g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58BS EN 61161:2007This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 October 2007 BSI 2007ISBN 978 0 580 50695 6National forewordThis British St
3、andard was published by BSI. It is the UK implementation of EN 61161:2007. It is identical with IEC 61161:2006. It supersedes BS EN 61161:1995 which is withdrawn.The UK participation in its preparation was entrusted to Technical Committee EPL/87, Ultrasonics.A list of organizations represented on th
4、is committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunity from legal obligations.Amendments issued since
5、 publicationAmd. No. Date CommentsEUROPEAN STANDARD EN 61161 NORME EUROPENNE EUROPISCHE NORM April 2007 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassar
6、t 35, B - 1050 Brussels 2007 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 61161:2007 E ICS 17.140.50 Supersedes EN 61161:1994 + A1:1998English version Ultrasonics - Power measurement - Radiation force balances and performance r
7、equirements (IEC 61161:2006) Ultrasons - Mesurage de puissance - Balances de forces de rayonnement et exigences de fonctionnement (CEI 61161:2006) Ultraschall - Leistungsmessung - Schallfeldkraft-Waagen und Anforderungen an ihre Funktionseigenschaften (IEC 61161:2006) This European Standard was appr
8、oved by CENELEC on 2007-03-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nati
9、onal standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own languag
10、e and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia
11、, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. EN 61161:2007 2 Foreword The text of document 87/325/CDV, future edition 2 of IEC 61161, prepared by IEC TC 87, Ultrasonics, was submitted to the
12、 IEC-CENELEC parallel Unique Acceptance Procedure and was approved by CENELEC as EN 61161 on 2007-03-01. This European Standard supersedes EN 61161:1994 + A1:1998. The main significant changes are: the main body of the standard has been restricted to normative statements; informative statements on c
13、orresponding aspects of ultrasonic power measurement and radiation force balances have been collected in Annex A; Annexes A, D, E and F are new; more radiation force balance arrangements are dealt with. The new material relates particularly to power measurement of ultrasonic physiotherapy devices. T
14、he following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2007-12-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2010-03-01 The followi
15、ng print types are used: requirements: roman type; notes: small roman type; words in bold in the text are defined in Clause 3. The numbers in square brackets refer to the Bibliography (after the annexes). Annex ZA has been added by CENELEC. _ Endorsement notice The text of the International Standard
16、 IEC 61161:2006 was approved by CENELEC as a European Standard without any modification. _ 3 EN 61161:2007 CONTENTS INTRODUCTION.5 1 Scope 6 2 Normative references .6 3 Terms and definitions .7 4 List of symbols .8 5 Requirements for radiation force balances 9 5.1 General .9 5.2 Target type9 5.3 Tar
17、get diameter .10 5.4 Balance / Force measuring system.10 5.5 System tank 10 5.6 Target support structures.10 5.7 Transducer positioning 10 5.8 Anti-streaming foils11 5.9 Transducer coupling 11 5.10 Calibration.11 6 Requirements for measuring conditions.11 6.1 Lateral target position11 6.2 Transducer
18、-target separation .11 6.3 Water 11 6.4 Water contact 11 6.5 Environmental conditions.12 6.6 Thermal drifts 12 7 Measurement uncertainty12 7.1 General .12 7.2 Balance system including target suspension.12 7.3 Linearity and resolution of the balance system .12 7.4 Extrapolation to the moment of switc
19、hing the ultrasonic transducer.13 7.5 Target imperfections13 7.6 Reflecting target geometry.13 7.7 Lateral absorbers in the case of reflecting target measurements.13 7.8 Target misalignment 13 7.9 Ultrasonic transducer misalignment13 7.10 Water temperature.13 7.11 Ultrasonic attenuation and acoustic
20、 streaming13 7.12 Foil properties .14 7.13 Finite target size14 7.14 Plane-wave assumption .14 7.15 Environmental influences.14 7.16 Excitation voltage measurement.14 7.17 Ultrasonic transducer temperature .14 7.18 Non-linearity14 7.19 Other sources14 EN 61161:2007 4 Annex A (informative) Additional
21、 information on various aspects of radiation force measurements16 Annex B (normative) Basic formulae.28 Annex C (informative) Other methods of ultrasonic power measurement .31 Annex D (informative) Propagation medium and degassing.32 Annex E (informative) Radiation force measurement with diverging u
22、ltrasonic beams37 Annex F (informative) Limitations associated with the balance arrangements 41 Annex ZA (normative) Normative references to international publications with their corresponding European publications49 Bibliography .46 Figure 1 Section through an absorbing target .15 Figure 2 Linearit
23、y check: balance readout as a function of the input quantity .15 Figure D.1 Example of dissolved oxygen concentration as a function of time for 200 ml of vacuum degassed water in a glass with liquid surface area of 34 cm2.34 Figure D.2 Dissolved oxygen concentration as a function of time for 2 g/l,
24、4 g/l and 6 g/l of sodium sulphite in de-mineralized water and for different surface areas and volumes of water 35 Figure E.1 Piston result (oscillating curve) for P/cF as a function of ka, with “peak“ approximation (unbroken line) and the central, half-way curve (broken line) representing the corre
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN611612007ENULTRASONICSPOWERMEASUREMENTRADIATIONFORCEBALANCESANDPERFORMANCEREQUIREMENTSREMAINSCURRENT

链接地址:http://www.mydoc123.com/p-719634.html