EN 60761-1-2004 en Equipment for continuous monitoring radioactivity in gaseous effluents Part 1 General requirements《气态排出物放射性连续监控设备 第1部分 一般要求 IEC 60761-1-2002 修改件》.pdf
《EN 60761-1-2004 en Equipment for continuous monitoring radioactivity in gaseous effluents Part 1 General requirements《气态排出物放射性连续监控设备 第1部分 一般要求 IEC 60761-1-2002 修改件》.pdf》由会员分享,可在线阅读,更多相关《EN 60761-1-2004 en Equipment for continuous monitoring radioactivity in gaseous effluents Part 1 General requirements《气态排出物放射性连续监控设备 第1部分 一般要求 IEC 60761-1-2002 修改件》.pdf(36页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS EN 60761-1:2004 Incorporating Amendment No. 1 (renumbers the BS IEC as BS EN 60761-1:2004) Equipment for continuous monitoring of radioactivity in gaseous effluents Part 1: General requirements The European Standard EN 60761-1:2004 has the status of a British Standard. ICS 13.280
2、 BS EN 60761-1:2004 This British Standard, having been prepared under the direction of the Engineering Sector Policy and Strategy Committee, was published under the authority of the Standards Policy and Strategy Committee on 4 December 2002 BSI 13 April 2005 ISBN 0 580 40886 8 National foreword This
3、 British Standard is the official English language version of EN 60761-1:2004. It is identical with IEC 60761-1:2002. The UK participation in its preparation was entrusted to Technical Committee NCE/2, Health physics instrumentation, which has the responsibility to: The CENELEC common modifications
4、have been implemented at the appropriate places in the text. The start and finish of each common modification is indicated in the text by tags . A list of organizations represented on this committee can be obtained on request to its secretary. Cross-references The British Standards which implement i
5、nternational publications referred to in this document may be found in the BSI Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Search” facility of the BSI Electronic Catalogue or of British Standards Online. This publication does not purport to i
6、nclude all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. aid enquirers to understand the text; present to the responsible international/European committee any en
7、quiries on the interpretation, or proposals for change, and keep the UK interests informed; monitor related international and European developments and promulgate them in the UK. Summary of pages This document comprises a front cover, an inside front cover, the EN title page, pages 2 to 33 and a bac
8、k cover. The BSI copyright date displayed in this document indicates when the document was last issued. Amendments issued since publication Amd. No. Date Comments 15427 13 April 2005 Renumbers BS IEC 60761-1:2002 as BS EN 60761-1:2004EUROPEAN STANDARD EN 60761-1 NORME EUROPENNE EUROPISCHE NORM Decem
9、ber 2004 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2004 CENELEC - All rights of exploitation in any form and by any means
10、reserved worldwide for CENELEC members. Ref. No. EN 60761-1:2004 E ICS 13.280 English version Equipment for continuous monitoring radioactivity in gaseous effluents Part 1: General requirements (IEC 60761-1:2002, modified) Equipements de surveillance en continu de la radioactivit dans les effluents
11、gazeux Partie 1: Exigences gnrales (CEI 60761-1:2002, modifie) Einrichtungen zur kontinuierlichen berwachung von Radioaktivitt in gasfrmigen Ableitungen Teil 1: Allgemeine Anforderungen (IEC 60761-1:2002, modifiziert) This European Standard was approved by CENELEC on 2004-11-01. CENELEC members are
12、bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to th
13、e Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the s
14、ame status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Port
15、ugal, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. Foreword The text of the International Standard IEC 60761-1:2002, prepared by SC 45B, Radiation protection instrumentation, of IEC TC 45, Nuclear instrumentation, together with the common modifications prepared by the CENELEC B
16、TTF 111-3 Instrumentation for ionizing radiation measurement and protection, was submitted to the formal vote and was approved by CENELEC as EN 60761-1 on 2004-11-01. The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical na
17、tional standard or by endorsement (dop) 2005-11-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2007-11-01 Subclauses, notes and annexes that are additional to those in the IEC standard are prefixed with the letter Z. Annex ZA has been added by CENEL
18、EC. Endorsement notice The text of the International Standard IEC 60761-1:2002 was approved by CENELEC as a European Standard with agreed common modifications. _ Page2 EN607611:2004 CONTENTS 1 Scope and object4 2 Normative references4 3 Terms, definitions and units 5 4 Symbols and abbreviations .9 5
19、 General requirements .9 6 Types of monitors .9 7 Sampling of the effluent 10 8 Collection of activity11 9 Measurement and indication characteristics 11 10 Reliability12 11 Flow-rate characteristics of a fractional sample of effluent stream .12 12 Alarms13 13 Indication facilities 13 14 Facilities f
20、or operational testing.14 15 Adjustment and maintenance facilities.14 16 Detection assembly or sampling and detection assembly.14 17 Control and measurement assembly .15 18 Ambient background shielding or compensation devices .15 19 Acoustic noise level of the assembly.15 20 Electromagnetic interfer
21、ence.16 21 Power supply16 22 General test procedures16 23 Tests performed under standard test conditions 17 24 Tests performed with variation of influence quantities17 25 Statistical fluctuations .17 26 Performance characteristics17 27 Electrical and mechanical characteristics 20 28 Environmental pe
22、rformance characteristics .23 29 Tests of the air circuit .25 30 Type test report and certificate27 31 Operation and maintenance manual27 Annex ZA (normative) Normative references to international publications with their corresponding European publications32 Table 1 Reference conditions and standard
23、 test conditions .28 Table 2 Tests performed under standard test conditions .29 Table 3 Tests performed with variation of influence quantities.30 Table 4 Tests of air circuit 31 Page3 EN607611:2004 EQUIPMENT FOR CONTINUOUS MONITORING OF RADIOACTIVITY IN GASEOUS EFFLUENTS Part 1: General requirements
24、 1 Scope and object This part of IEC 60761 defines acceptable forms of such monitoring, provides some general guidance as to the possible range of measurement and capability of such equipment as may be envisaged, and indicates when and where its uses may be practicable. This standard is applicable t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN6076112004ENEQUIPMENTFORCONTINUOUSMONITORINGRADIOACTIVITYINGASEOUSEFFLUENTSPART1GENERALREQUIREMENTS

链接地址:http://www.mydoc123.com/p-718845.html