EN 15544-2009 en One off Kachelgrund fen Putzgrund fen (tiled mortared stoves) - Dimensioning《一次性砖瓦炉 灰泥炉尺寸》.pdf
《EN 15544-2009 en One off Kachelgrund fen Putzgrund fen (tiled mortared stoves) - Dimensioning《一次性砖瓦炉 灰泥炉尺寸》.pdf》由会员分享,可在线阅读,更多相关《EN 15544-2009 en One off Kachelgrund fen Putzgrund fen (tiled mortared stoves) - Dimensioning《一次性砖瓦炉 灰泥炉尺寸》.pdf(22页珍藏版)》请在麦多课文档分享上搜索。
1、BS EN 15544:2009ICS 97.100.30NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBRITISH STANDARDOne offKachelgrundfen/Putzgrundfen (tiled/mortared stoves) DimensioningThis British Standardwas published under theauthority of the StandardsPolicy and StrategyCommittee on 31 August200
2、9 BSI 2009ISBN 978 0 580 57332 3Amendments/corrigenda issued since publicationDate CommentsBS EN 15544:2009National forewordThis British Standard is the UK implementation of EN 15544:2009.The UK participation in its preparation was entrusted to TechnicalCommittee RHE/28, Domestic solid mineral fuel
3、appliances.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisionsof a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immun
4、ityfrom legal obligations.BS EN 15544:2009EUROPEAN STANDARDNORME EUROPENNEEUROPISCHE NORMEN 15544July 2009ICS 97.100.30English VersionOne off Kachelgrundfen/Putzgrundfen (tiled/mortared stoves)- DimensioningPoles en faence, poles en maonnerie fabriqus in situ -DimensionnementOrtsfest gesetzte Kachel
5、grundfen/Putzgrundfen -AuslegungThis European Standard was approved by CEN on 19 June 2009.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date li
6、sts and bibliographical references concerning such nationalstandards may be obtained on application to the CEN Management Centre or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the respo
7、nsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as theofficial versions.CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,France, Germany, Greece, Hungary, Icela
8、nd, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMIT EUROPEN DE NORMALISATIONEUROPISCHES KOMITEE FR NORMUNGManagement Centre: Avenue Marni
9、x 17, B-1000 Brussels 2009 CEN All rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 15544:2009: EBS EN 15544:2009EN 15544:2009 (E) 2 Contents Page Foreword 3Introduction .41 Scope 52 Normative references 53 Terms and definitions .54 Calculati
10、ons 74.1 Nominal heat output 74.2 Load of fuel .74.2.1 Maximum load 74.2.2 Minimum load .74.3 Design of the essential dimensions.74.3.1 Combustion chamber dimensions .74.3.2 Minimum flue pipe length .94.3.3 Gas groove profile .94.4 Calculation of the burning rate 104.5 Fixing of the air ratio 104.6
11、Combustion air, flue gas 104.6.1 Combustion air flow rate 104.6.2 Flue gas flow rate 114.6.3 Flue gas mass flow rate . 114.7 Calculations of the density 124.7.1 Combustion air density 124.7.2 Flue gas density 124.8 Calculation of the flue gas temperature . 124.8.1 Mean combustion chamber temperature
12、 . 124.8.2 Flue gas temperature in the flue pipe . 134.8.3 Flue gas temperature in the connecting pipe 134.8.4 Flue gas temperature at chimney entrance, mean flue gas temperature of the chimney and temperature of the chimney wall at the top of the chimney . 134.9 Calculation of flow mechanics 134.9.
13、1 Calculation of the standing pressure . 134.9.2 Calculation of the flow velocity . 144.9.3 Calculation of the static friction 144.9.4 Calculation of the resistance due to direction change . 154.10 Operation control 174.10.1 Pressure condition . 174.10.2 Dew point condition 174.10.3 Efficiency of th
14、e combustion . 174.10.4 Flue gas triple of variates 18Bibliography . 19BS EN 15544:2009EN 15544:2009 (E) 3 Foreword This document (EN 15544:2009) has been prepared by Technical Committee CEN/TC 295 “Residential solid fuel burning appliances”, the secretariat of which is held by BSI. This European St
15、andard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by January 2010, and conflicting national standards shall be withdrawn at the latest by January 2010. Attention is drawn to the possibility that some of the elements o
16、f this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European
17、 Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kin
18、gdom. BS EN 15544:2009EN 15544:2009 (E) 4 Introduction This standard specifies a calculation method for the dimensioning of Kachelgrundfen/Putzgrundfen (tiled/mortared stoves) based upon the required nominal heat output of the stove as declared by the producer. If the calculations of this standard a
19、re observed, the minimum energy efficiency of 78% and the emission values of carbon monoxide 1 500 mg/mn (1 000 mg/MJ), nitrogen dioxide 225 mg/mn (150 mg/MJ), organically bound carbon 120 mg/mn (80 mg/MJ) and dust 90 mg/mn (60 mg/MJ) will be observed too. This calculation method for the dimensionin
20、g of Kachelgrundfen/Putzgrundfen (tiled/mortared stoves) is based on appropriate literature as well as EN 13384-1, and where empirically determined correlations are used in addition to physical and chemical formulas. NOTE In case of a calculation method for different interior materials than fireclay
21、 the proof of the compliance of the emission values should be delivered separately. Furthermore the empiric data of the combustion chamber dimensions, the minimum flue pipe length, the burning rate as well as the combustion chamber temperature and the decrease of the temperature along the flue pipe
22、should also be determined. BS EN 15544:2009EN 15544:2009 (E) 5 1 Scope This standard specifies calculations for the dimensioning of Kachelgrundfen/Putzgrundfen (tiled/mortared stoves) based upon the required nominal heat output of the stove as declared by the producer. The Kachelgrundfen/Putzgrundfe
23、n (tiled/mortared stoves) are of individual one-off construction design. The standard can be used for log wood fired Kachelfen (tile stoves) that burn one fuel load per storage period with a maximum load between 10 kg and 40 kg and a storage period (nominal heating time) between 8 h and 24 h. This s
24、tandard is valid for Kachelgrundfen/Putzgrundfen (tiled/mortared stoves) equipped with fireclay as interior material, with an apparent density between 1,750 kg/m and 2,200 kg/m, a degree of porosity from 18 % up to 33 % by volume and a heat conductivity from 0,65 W/mK up to 0,90 W/mK (temperature ra
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN155442009ENONEOFFKACHELGRUNDFENPUTZGRUNDFENTILEDMORTAREDSTOVESDIMENSIONING 一次性 砖瓦 炉灰 尺寸 PDF

链接地址:http://www.mydoc123.com/p-715170.html