EN 14671-2006 en Characterization of sludges - Pre-treatment for the determination of extractable ammonia using 2 mol l potassium chloride《淤泥特性 用2mol l氯化钾测定可萃取氨的预处理》.pdf
《EN 14671-2006 en Characterization of sludges - Pre-treatment for the determination of extractable ammonia using 2 mol l potassium chloride《淤泥特性 用2mol l氯化钾测定可萃取氨的预处理》.pdf》由会员分享,可在线阅读,更多相关《EN 14671-2006 en Characterization of sludges - Pre-treatment for the determination of extractable ammonia using 2 mol l potassium chloride《淤泥特性 用2mol l氯化钾测定可萃取氨的预处理》.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARDBS EN 14671:2006Characterization of sludges Pre-treatment for the determination of extractable ammonia using 2 mol/l potassium chlorideThe European Standard EN 14671:2006 has the status of a British StandardICS 13.030.20g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g
2、3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58BS EN 14671:2006This British Standard was published under the authority of the Standards Policy and Strategy Committee on 30 April 2007 BSI 2007ISBN 978 0 580 50513
3、 3National forewordThis British Standard was published by BSI. It is the UK implementation of EN 14671:2006.The UK participation in its preparation was entrusted to Technical Committee EH/5, Sludge characterization.A list of organizations represented on EH/5 can be obtained on request to its secreta
4、ry.The UK committee has never seen the need to standardize this method at a European level and, as a consequence, has not been actively involved in the development of this standard. However, the UK committee is pleased that a classic British method was selected. The method has long been used as a va
5、luable operational-control method and is available in existing technical literature (see reference 1 in the bibliography of this standard). Due to the difficulty and cost of sending liquid sludge samples (in such a manner that their properties do not change) to laboratories for international interla
6、boratory trials of the performance of this method, interested parties convened at a workshop to assess the test. Their conclusion was that the results are operationally defined (e.g. by the filter paper used) and, as the document does not specify all such operational details, the performance data ar
7、e not really applicable outside the context of the workshop. As a result, the members of EH/5 have no information to offer on the reproducibility of the results.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.
8、Compliance with a British Standard cannot confer immunity from legal obligations. Amendments issued since publicationAmd. No. Date CommentsEUROPEAN STANDARDNORME EUROPENNEEUROPISCHE NORMEN 14671June 2006ICS 13.030.20English VersionCharacterization of sludges - Pre-treatment for the determinationof e
9、xtractable ammonia using 2 mol/l potassium chlorideCaractrisation des boues - Prtraitement pour ladtermination de lAzote ammoniacal extractible utilisant2mol/l de chlorure de potassiumCharakterisierung von Schlmmen - Vorbehandlung zurBestimmung des extrahierbaren Ammoniums unterVerwendung von 2 mol/
10、l KaliumchloridThis European Standard was approved by CEN on 24 May 2006.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliograp
11、hical references concerning such nationalstandards may be obtained on application to the Central Secretariat or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN m
12、ember into its own language and notified to the Central Secretariat has the same status as the officialversions.CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France,Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lith
13、uania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania,Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMIT EUROPEN DE NORMALISATIONEUROPISCHES KOMITEE FR NORMUNGManagement Centre: rue de Stassart, 36 B-1050 Brussels 2006 CEN
14、 All rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 14671:2006: EEN 14671:2006 (E) 2 Contents Page Foreword3 Introduction .4 1 Scope 5 2 Normative references 5 3 Terms and definitions .5 4 Principle5 5 Limitations and interferences.5 6 Haza
15、rds .6 7 Reagents.6 8 Apparatus .6 9 Sample pre-treatment7 10 Procedure .7 11 Expression of results 8 12 Test report 8 Annex A (informative) Performance data of the interlaboratory comparison Summary of sludge exchangeable ammonia results.9 Bibliography. 11 EN 14671:2006 (E) 3 Foreword This document
16、 (EN 14671:2006) has been prepared by Technical Committee CEN/TC 308 “Characterization of sludges”, the secretariat of which is held by AFNOR. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by Decem
17、ber 2006, and conflicting national standards shall be withdrawn at the latest by December 2006. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Cyprus, Czech Republic,
18、Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EN 14671:2006 (E) 4 Introduction Because sludge may be applie
19、d to land as manure or as a disposal, there is a need to monitor extractable ammonia. EN 14671:2006 (E) 5 1 Scope This European standard specifies a procedure for the determination of extractable ammonia using a 2 mol/l potassium chloride solution in raw and digested sewage sludges. The range of the
20、 method is up to 100 g/kg N assuming appropriate dilution of the potassium chloride extract in the final measurement step. NOTE The above wording will be modified once the round robin results are available. It may be suitable for other types of sludges, but the user should validate the method using
21、these sludges. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 12880:20
22、00, Characterization of sludges Determination of dry residue and water content EN ISO 3696:1995, Water for analytical laboratory use Specification and test methods (ISO 3696:1987) 3 Terms and definitions For the purposes of this European Standard, the following terms and definitions apply. 3.1 extra
23、ctable ammonia ammonia that is released when the homogenised sludge is shaken with 2 mol/l potassium chloride for 1 h at room temperature 3.2 dry residue dry mass portion of the sludge obtained after the specified drying process, expressed as a percentage EN 12880:2000, 3.1 4 Principle An aliquot of
24、 the homogenised sludge is shaken for 1 h with 2 mol/l potassium chloride at room temperature. The sample is then filtered and the ammonia determined by a suitable method. Potassium chloride (2 mol/l) is used rather than water to ensure that both soluble and ion exchangeable forms of the determinand
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN146712006ENCHARACTERIZATIONOFSLUDGESPRETREATMENTFORTHEDETERMINATIONOFEXTRACTABLEAMMONIAUSING2MOLLPOTASSIUMCHLORIDE

链接地址:http://www.mydoc123.com/p-714391.html