DOD A-A-53847-1989 SPECIMEN KIT URINE《尿样本工具》.pdf
《DOD A-A-53847-1989 SPECIMEN KIT URINE《尿样本工具》.pdf》由会员分享,可在线阅读,更多相关《DOD A-A-53847-1989 SPECIMEN KIT URINE《尿样本工具》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、- A-A-53847 65 799797q 0032384 3 = A-A- 53 8 47 24 March 1989 COMMERCIAL ITEM DESCRIPTION SPECIMEN KIT, URINE The General Services Administration has authorized the use of this Commercial Item Description as a replacement for Military Specification MIL-S-37498 which is cancelled. This Commercial Ite
2、m Description covers an integrated set of compatible, non-sterile components suitable for collecting, transporting, and testing of urine specimens. Salient characteristics: The urine specimen kit shall consist of the following integrated set of compatible non-sterile components for urine specimen co
3、llection, transport, and analysis: 500 - Clear plastic calibrated urine specimen tubes. 500 - Snap caps for tubes. 500 - Adhesive labels for tubes. 50Q - Urine specimen collection cups. 4 minimum quantity - Holders for urine specimen tubes. Urine Specimen Tube. The urine specimen tube shall be made
4、of clear plastic and shall have a capacity of 15 plus or minus 1 milliliters (mi). The top of the tube shall be circular and it shall have a lip to accommodate the snap cap. The tube may terminate in a point (may be slightly rounded) at the bottom to facilitate the collection of centrifuged precipit
5、ate. walls of the tube shall be straight, or shall taper inward toward the bottom. approximate dimensions: The The tube shall have the following Diameter of lip - 7/8 inches Outside diameter - 5/8 inches of tube below lip Length of tube - 4-1/8 inches The tube shall have graduated markings at the 1/
6、4 ml, 1/2 ml or 1 ml level and the-12 ml level. Additional graduation marks shall be acceptable. The tube shall have no breaks, holes, cracks, or sharp edges. AMSC N/A DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. FSC 6530 THIS DOCUMENT CONTAINS 7 PAGES. Provided
7、by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-5 3 8 41 Snap Cap. The cap shall be an easy-on, easy-off plastic snap cap. It may have an integral lift tab or rim. It shall snap on and off the lip of the tube without undue effort and shall fit securely ov
8、er the opening of the tube. The cap shall have no breaks, tears, or sharp edges, and shall protect contents of the tube from dust, other contamination, and spillage. The tube and cap shall show no evidence of leakage when tested. Label. The label shall be white and shall measure 1-3/4 plus or minus
9、1/4 inches by 1-1/4 plus or minus 1/4 inches. The label shall be imprinted with at least three lines for recording data. It shall accept and retain writing from a standard ball-point pen. The label shall be coated on one side with an all-purpose, permanent pressure-sensitive adhesive. The adhesive s
10、urface shall be protected by a strip of suitable removable backing material. The label shall peel freely from the backing and shall adhere firmly to the specimen tube. The label shall not lift or separate from the tube when tested. Cup. The cup shall have a capacity of not less than 3 ounces and sha
11、ll be fabricated of a material suitable for the collection of urine. The cup shall have a flat bottom so that it can stand on a level surface when filled, without rock or wobble. Cups may be constructed so that they can be nested to conserve storage space. The cup shall contain no tears or holes. Th
12、e cup shall show no evidence of leakage when tested. Tube Holder. The tube holder shall be fabricated of cardboard, plastic, or other suitable material, free of tears or other deformations. It shall have inserts, approximately 1-1/2 inches deep, or at least two levels of concentric holes, to hold 10
13、 or more specimen tubes in an upright position. It shall be supplied fully assembled, or shall be capable of being assembled, without the use of tools, fasteners, or adhesive in three minutes or less. The holder shall show no evidence of spillage, deformation, or other failure when tested. All compo
14、nents of the kit shall be free of dirt, oil, grease, or other contamination. Workmanship. The urine specimen kit shall be free from defects which detract from its appearance or impair its serviceability. kit, containing 500 tubes, 500 caps, 500 labels, 500 cups, and four holders as specified, consti
15、tutes one unit. Unit. Package (PG). One package consisting of one specimen 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-53847 65 7999974 O032186 7 W - A-A-5 3 a 47 Quality Assurance Provisions. the contract or purchase order, the contractor
16、is responsible for the performance of all inspection requirements as specified herein. Except as otherwise specified in the contract or purchase order, the contractor may use his own or any facilities suitable for the performance of the inspection requirements specified herein, unless disapproved by
17、 the Government. The Government reserves the right to perform any of the inspections set forth in the specification where such inspections are deemed necessary to assure supplies and services conform to prescribed requirements. Responsibility for inspection. Unless otherwise specified in Records. Re
18、cords of examinations and tests performed by or for the contractor shall be maintained by the contractor and made available to the Government upon the Governments request, at any time, or from time to time, during the performance of the contract and for a period of three years after delivery of the
19、supplies to which such records relate, Inspection. Inspection, as used herein, is defined as both examination (such as visual or auditory investigation without the use of special laboratory appliances or procedures) and testing (determination by technical means of physical and chemical properties) o
20、f the item. Tests. Tests shall be conducted to determine compliance with specification requirements. shall be used for the determination of two or more test characteristics. Where feasible, the same sample Samplinq for examination. Sampling for examination shall be conducted in accordance with MIL-S
21、TD-105, with an AQL of 1.0 (percent defective) and an inspection level of II. The unit of product for examination purposes shall be one urine specimen kit as specified in this description. Defects Complete Kit Any component is not provided. Count is less than specified. Marking of components and pac
22、kages is not complete or not present. 3 x _- u Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A- 5 3 8 4 7 Cap Defects (continued) Not free of grease, oil, and dirt. Not free of sharp edges. Not free of breaks and tears. Does not fit securely on s
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DODAA538471989SPECIMENKITURINE 样本 工具 PDF