DLA MIL-PRF-19207 G-2013 FUSEHOLDERS EXTRACTOR POST TYPE BLOWN FUSE INDICATING AND NONINDICATING GENERAL SPECIFICATION FOR.pdf
《DLA MIL-PRF-19207 G-2013 FUSEHOLDERS EXTRACTOR POST TYPE BLOWN FUSE INDICATING AND NONINDICATING GENERAL SPECIFICATION FOR.pdf》由会员分享,可在线阅读,更多相关《DLA MIL-PRF-19207 G-2013 FUSEHOLDERS EXTRACTOR POST TYPE BLOWN FUSE INDICATING AND NONINDICATING GENERAL SPECIFICATION FOR.pdf(21页珍藏版)》请在麦多课文档分享上搜索。
1、AMSC N/A FSC 5920 INCH-POUND MIL-PRF-19207G 13 June 2013 SUPERSEDING MIL-PRF-19207F 15 May 2007 PERFORMANCE SPECIFICATION FUSEHOLDERS, EXTRACTOR POST TYPE, BLOWN FUSE, INDICATING AND NONINDICATING, GENERAL SPECIFICATION FOR This specification is approved for use by all Departments and Agencies of th
2、e Department of Defense. 1. SCOPE 1.1 Scope. This specification covers the general requirements and test procedures for enclosed, panel mounted, extractor post type electrical fuseholders, both blown fuse indicating and nonindicating. 1.2 Classification. Fuseholder types will be of the following cha
3、racteristics, construction, enclosures, and styles as specified below. 1.2.1 Part or Identifying Number (PIN). The PIN designation should be in the following form: FH L 17 G I Component Characteristic (see 1.2.2) Structure (see 1.2.3) Enclosure (see 1.2.4) Style (see 1.2.5) The component is identifi
4、ed by the two-letter symbol “FH” and covers all fuse-holder types under this specification. 1.2.2 Characteristic. The characteristic is identified by a single letter “L” or “N” which signify the following: L - Indicating (blown fuse indication feature) N - Nonindicating. 1.2.3 Structure. The structu
5、re is identified by a two-digit number and indicates the design and physical dimensions of a particular holder as prescribed by a specific performance specification sheet. Comments, suggestions, or questions on this document should be addressed to: DLA Land and Maritime, ATTN: DLA Land and Maritime-
6、VAT, Post Office Box 3990, Columbus, Ohio 43218-3990 or emailed to CircuitProtectdla.mil. Since contact information can change, you may want to verify the currency of this address information using the ASSIST Online database at https:/assist.dla.mil. Provided by IHSNot for ResaleNo reproduction or n
7、etworking permitted without license from IHS-,-,-MIL-PRF-19207G 2 1.2.4 Enclosure. The degree of enclosure is indicated by a single or double letter which denotes the following: U - Unsealed G - Dripproof S - Splashproof W - Watertight WS - Watertight with EMI/RFI shielding WB - Watertight and body
8、sealed WBS - Watertight and body sealed with EMI/RFI shielding 1.2.5 Style. When more than one style of fuseholder is provided within a single type and rating, each style is designated by a single number. When only one style is provided, the style number is omitted from the type designation. 2. APPL
9、ICABLE DOCUMENTS 2.1 General. The documents listed in this section are specified in sections 3 and 4 of this specification. This section does not include documents cited in other sections of this specification or recommended for additional information or as examples. While every effort has been made
10、 to ensure the completeness of this list, document users are cautioned that they must meet all specified requirements of documents cited in sections 3 and 4 of this specification, whether or not they are listed. 2.2 Government documents. 2.2.1 Specifications, standards, and handbooks. The following
11、specifications, standards, and handbooks form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract (see 6.2). FEDERAL STANDARDS FED-STD-H28 - Screw-Thread Standards for Federal Services. FED-
12、STD-H28/2 - Screw-Thread Standards for Federal Services Section 2, Unified Inch Screw Threads - UN and UNR Thread Forms. FED-STD-595/26307 - Gray, Semigloss. DEPARTMENT OF DEFENSE SPECIFICATIONS MIL-PRF-15160 - Fuses, Instrument, Power, and Telephone, General Specification for. MIL-PRF-23419 - Fuse,
13、 Cartridge, Instrument Type, General Specification for. (See supplement 1 for list of associated specifications.) DEPARTMENT OF DEFENSE STANDARDS MIL-STD-108 - Definitions of and Basic Requirements for Enclosures for Electric and Electronic Equipment. MIL-STD-202 - Test Methods for Electronic and El
14、ectrical Component Parts. MIL-STD-1285 - Marking of Electrical and Electronic Parts. (Copies of these documents are available online at http:/quicksearch.dla.mil or https:/assist.dla.mil or from DLA Document Services, Building 4/D, 700 Robbins Avenue, Philadelphia, PA 19111-5094). Special notice: Co
15、pies of FED-STD-595/26307 for non-DoD organizations can be obtained only by calling (215) 697-6396, or by faxing (215) 697-9398 for ordering instructions and current price. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-19207G 3 2.3 Non-Gove
16、rnment publications. The following documents form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract (see 6.2). INTERNATIONAL ORGANIZATION FOR STANDARDS (ISO) ISO 10012 - Measurement Manage
17、ment Systems - Requirements for Measurement Processes and Measuring Equipment. ISO/IEC 17025 - General Requirements for the Competence of Testing and Calibration Laboratories. (Copies of these documents are available online at http:/www.iso.org/iso/home.html or from the American National Standards I
18、nstitute (ANSI), 1899 L Street, NW, 11th Floor, Washington, DC 20036-3801). UNDERWRITERS LABORATORIES, INCORPORATED (UL) UL 94 - Safety Tests for Flammability of Plastic Materials for Parts in Devices and Appliances, Standard For. (Copies of this document are available online at http:/ or from the U
19、nderwriters Laboratories Incorporated, 2600 N. W. Lake Road, Camas, WA 98607-8542). 2.4 Order of precedence. Unless otherwise noted herein or in the contract, in the event of conflict between the text of this document and the references cited herein (expect for related specification sheets), the tex
20、t of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 Specification sheets. The individual item requirements shall be as specified herein and in accordance with the applica
21、ble specification sheet. In the event of any conflict between the requirements of this specification and the specification sheet, the latter shall govern (see 6.2). 3.2 Qualification. Fuseholders furnished under this specification shall be products that are authorized by the qualifying activity for
22、listing on the applicable qualified products list at the time of award of contract (see 4.4 and 6.3). 3.3 Materials. Materials shall be as specified herein. However, when a definite material is not specified, a material shall be used which will enable the fuseholders to meet the performance requirem
23、ents of this specification. Acceptance or approval of any constituent material shall not be construed as a guaranty of the acceptance of the finished product. 3.3.1 Restricted materials. 3.3.1.2 Flammable material. Material used shall be fire retardant and have a minimum flammability rating of UL 94
24、HB. 3.3.1.3 Toxic and hazardous material. Flammable or explosive material, or material which can produce toxic, suffocating or corrosive fumes, which would be detrimental to the performance of the equipment or health of personnel, shall not be used in construction of the fuseholders. Provided by IHS
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAMILPRF19207G2013FUSEHOLDERSEXTRACTORPOSTTYPEBLOWNFUSEINDICATINGANDNONINDICATINGGENERALSPECIFICATIONFORPDF

链接地址:http://www.mydoc123.com/p-692255.html