DLA MIL-DTL-49285 24 A-2010 CABLE SPECIAL PURPOSE ELECTRICAL FOUR INDIVIDUALLY SHIELDED PAIRS OF 22 (7 X 28) AWG.pdf
《DLA MIL-DTL-49285 24 A-2010 CABLE SPECIAL PURPOSE ELECTRICAL FOUR INDIVIDUALLY SHIELDED PAIRS OF 22 (7 X 28) AWG.pdf》由会员分享,可在线阅读,更多相关《DLA MIL-DTL-49285 24 A-2010 CABLE SPECIAL PURPOSE ELECTRICAL FOUR INDIVIDUALLY SHIELDED PAIRS OF 22 (7 X 28) AWG.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、 MIL-DTL-49285/24A 1 March 2010SUPERSEDING MIL-C-49285/24 19 October 1989 DETAIL SPECIFICATION SHEET CABLE, SPECIAL PURPOSE, ELECTRICAL, FOUR INDIVIDUALLY SHIELDED PAIRS OF 22 (7 X 28) AWG This specification is approved for use by all Departments and Agencies of the Department of Defense. The requir
2、ements for acquiring the product described herein shall consist of this specification sheet and MIL-DTL-49285. FIGURE 1. Cable illustration. AMSC N/A FSC 6145 INCH-POUND Inactive for new design after 16 June 1997. Provided by IHSNot for ResaleNo reproduction or networking permitted without license f
3、rom IHS-,-,-MIL-DTL-49285/24A 2 Engineering information: See table I. Note: Not for aerospace use. TABLE I. Description, electrical. Electrical characteristics Requirements Nominal capacitance between conductors Nominal capacitance between the conductor and the shield with one conductor tied to the
4、shield Continuous working voltage Nominal capacitance between adjacent shields Continuous working voltage between adjacent shields Shield dc resistance 27 pF/ft (picofarads/foot) 49 pF/ft 400 V rms maximum between conductors 150 pF/ft 50 volts maximum 14 ohms/1,000 feet maximum TABLE II. Description
5、, physical. Components Construction details Number of conductors Conductor type and wire size Conductor stranding Conductor insulation Conductor insulation thickness Drain wire type and size Drain wire stranding Jacket material Jacket thickness Finished cable diameter Cable style (UL) Tensile streng
6、th (jacket) Elongation (jacket) Overall cabling lay lengths Four individually shielded Stranded tinned copper 20 AWG 7 X 28 AWG Polypropylene 0.015 inch nominal thickness Stranded tinned copper 22 AWG 7 X 30 AWG Polyvinyl chloride 0.030 inch 0.380 inch maximum outside diameter Not applicable 2,000 p
7、ounds per square inch minimum 150 percent minimum 5.7 twists per foot 10 percent Cabled pair orientation: The position of the red and green pair shield shall determine the rotation direction for pair location (see figure 1). Provided by IHSNot for ResaleNo reproduction or networking permitted withou
8、t license from IHS-,-,-MIL-DTL-49285/24A 3 TABLE III. Shield color code. Pair numbers Shield color Center core 1stpair 2ndpair 3rdpair 4thpair Red Green Blue Blue REQUIREMENTS: Design and construction: (see table II): Shield location and orientation. The polyester aluminum shield is to be located on
9、 the outer circumference of the pair, with the aluminum foil side outward. Insulation on the interior of the shield is to be complete with no aluminum available for contact. Drain wire location. The drain wire is to be spirally located between the noise reducing tape and the aluminum foil shield, an
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便