DLA MIL-DTL-45300 C-2011 CAP FUEL TANK FOR MILITARY COMBAT AND TACTICAL TRANSPORT VEHICLES.pdf
《DLA MIL-DTL-45300 C-2011 CAP FUEL TANK FOR MILITARY COMBAT AND TACTICAL TRANSPORT VEHICLES.pdf》由会员分享,可在线阅读,更多相关《DLA MIL-DTL-45300 C-2011 CAP FUEL TANK FOR MILITARY COMBAT AND TACTICAL TRANSPORT VEHICLES.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、 DETAIL SPECIFICATION CAP, FUEL TANK: FOR MILITARY COMBAT AND TACTICAL TRANSPORT VEHICLES Inactive for new design after 22 January 1999. This specification is approved for use by all Departments and Agencies of the Department of Defense. 1. SCOPE 1.1 Scope. This specification covers three types of f
2、uel tank caps intended for use on military vehicles. The type I and type II are vented, while the type III fuel tank cap is non-vented (see 6.1) 1.2 Classification. Fuel tank caps are of the following types as specified (see 6.2): Type I Vented cap with pressure relief valve and float assembly (MS51
3、300). Type II Vented cap with pressure relief valve and fording valve (MS35645). Type III Non-vented cap (MS53075). 2. APPLICABLE DOCUMENTS 2.1 General. The documents listed in this section are specified in sections 3, 4, or 5 of this standard. This section does not include documents cited in other
4、sections of this standard or recommended for additional information or as examples. While every effort has been made to ensure the completeness of this list, document users are cautioned that they must meet all specified requirements of documents cited in sections 3, 4, or 5 of this standard, whethe
5、r or not they are listed. 2.2 Government documents. 2.2.1 Specifications, standards and handbooks. The following specifications, standards, and handbooks form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the soli
6、citation or contract. DEPARTMENT OF DEFENSE STANDARDS MIL-STD-130 - Identification Marking of US Military Property. MS35644 - Filler Neck Assembly, Fuel Tank Military Vehicles. MS35645 - Cap, Fuel Tank: Tactical Vehicles, Fording. MS51300 - Cap, Fuel Tank: Combat Vehicle, Spill Proof. MS53075 - Cap,
7、 Fuel Tank: Tactical Vehicle Non-Vented. (Copies of these documents are available online at https:/assist.daps.dla.mil/quicksearch/ or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) AMSC N/A FSC 2910 Comments, suggestions, or questions on
8、 this document should be addressed to DLA, Land and Maritime, ATTN: VAI, P.O. Box 3990, Columbus, OH 43218-3990, or email to FluidFlowdla.mil. Since contact information can change, you may want to verify the currency of this address information using the ASSIST Online database at https:/assist.daps.
9、dla.mil. INCH-POUND MIL-DTL-45300C 20 July 2011 SUPERSEDING MIL-C-45300B 16 February 1988 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-45300C 2 2.2 Other publications. The following document forms a part of this specification to the extent
10、 specified herein. Unless otherwise specified, the issues of the documents which are DOD adopted shall be those listed in the issue of the DODISS specified in the solicitation. Unless otherwise specified, the issues of documents not listed in the DODISS shall be the issue of the nongovernment docume
11、nts which is current on the date of the solicitation. INTERNATIONAL ORGANIZATION FOR STANDARDIZATION (ISO) ISO 17025 - General requirements for the competence of testing and calibration laboratories (Copies of these documents are available online at http:/www.iso.ch or from the International Organiz
12、ation for Standardization American National Standards Institute, 11 West 42nd Street, 13th Floor, New York, NY 10036.) NCSL INTERNATIONAL NCSL Z540.3 - Laboratories, Calibration, and Measuring and Test Equipment (Copies of these documents are available online at http:/www.ncsli.org or from NCSL Inte
13、rnational 2995 Wilderness Place, Suite 107 Boulder, Colorado 80301-5404) 2.3 Order of precedence. Unless otherwise noted herein or in the contract, in the event of a conflict between the text of this document and the references cited herein, the text of this document takes precedence. Nothing in thi
14、s document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 First article. When specified (see 6.2), a sample shall be subjected to first article inspection in accordance with 4.4. 3.2 Materials (all types). Materials shall be as
15、 specified herein and in referenced specifications, standards and drawings. Materials shall be free of defects which adversely affect performance or serviceability of the finished product (see 4.6.1). 3.2.1 Recycled, virgin and reclaimed materials. There are no requirements for the exclusive use of
16、virgin materials. The use of recycled or reclaimed (recovered) materials is acceptable provided all other requirements of this specification are met (see 6.3.1). 3.3 Construction (all types) (see 4.6.1 and 4.6.2). 3.3.1 Type I. Type I caps shall conform to MS51300. 3.3.2 Type II. Type II caps shall
17、conform to MS35645. 3.3.3 Type III. Type III caps shall conform to MS53075. 3.4 Performance. 3.4.1 Torque. 3.4.1.1 Caps (all types). When connecting the cap to a filler neck conforming to MS35644 at temperatures of plus 125 to minus 65 degrees Fahrenheit (F), the torque shall be no greater than 70 i
18、nch-pounds attained before the cap hits the stop limit. The torque required to disconnect the cap from the filler neck at temperatures of plus 125 to minus 65F shall be not greater than 70 nor less than 25 inch-pounds. There shall be no visible evidence of binding (see 4.6.3.1). Provided by IHSNot f
19、or ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-45300C 3 3.4.1.2 Fording valve (type II only). The torque required to move the fording valve out of closed or open position shall be not less than 10 inch-ounces (see 4.6.3.2). 3.4.2 Leakage (all types). When teste
20、d as specified in 4.6.4, with a pressure of 2 pounds per square inch (psi) for type I and 1 psi for type II (with fording value closed) and type III caps, the leakage shall not exceed 0.5 ounce per minute. 3.4.3 Pressure relief valve opening. 3.4.3.1 Type I. When tested as specified in 4.6.5.1, the
21、pressure relief valve for type I caps shall open at between 4 to 5 psi, when the float is in the actuated condition. 3.4.3.2 Type II. When tested as specified in 4.6.5.2, the pressure relief valve for type II caps shall open at between 2 to 3 psi, when the fording valve is in the closed position. 3.
22、4.4 Free breathing (types I and II). When tested as specified in 4.6.6, type I and type II caps (type II cap with fording valve open) shall have an air flow through them of not less than 0.010 cubic foot per minute (cfm), at room temperature with 1 psi vacuum. 3.4.5 Shear strength (all types). When
23、tested as specified in 4.6.7, type I and type II caps shall withstand not less than 25 foot-pounds of applied torque before showing any rotation of the inner member with respect to the outer shell. Type II and type III caps shall withstand not less than 25 foot-pounds of applied torque before showin
24、g any rotation of cup on inner plate or inner plate on shell. 3.4.6 External pressure (types II and III). When tested as specified in 4.6.8, type II (with fording valves closed) and type III caps shall not leak. 3.5 Finish (all types). Unless otherwise specified (see 6.2), caps shall be finished on
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAMILDTL45300C2011CAPFUELTANKFORMILITARYCOMBATANDTACTICALTRANSPORTVEHICLESPDF

链接地址:http://www.mydoc123.com/p-690812.html