《DLA A-A-50549-1996 HEATERS WATER LIQUID FUEL (OIL-FIRED STORAGE TYPE NOT EXCEEDING 280 000 BTU H INPUT CAPACITY)《液体燃料热水器(石油燃料 储水式 不超过280000BTU H输入能力)》.pdf》由会员分享,可在线阅读,更多相关《DLA A-A-50549-1996 HEATERS WATER LIQUID FUEL (OIL-FIRED STORAGE TYPE NOT EXCEEDING 280 000 BTU H INPUT CAPACITY)《液体燃料热水器(石油燃料 储水式 不超过280000BTU H输入能力)》.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、 A-A-50549 = 9999974 0171784 446 W rnCH-POUND A-A-50549 June 13. 1996 SUPERSEDING 10 April 1992 MIL-H-1645 1F COMMERCIAL ITEM DESCRIPTION HEATERS, WATER, LIQUID FUEL 280,000 BTU/H INPUT CAPACITY) (OIL-FIRED, STORAGE TYPE, NOT EXCEEDING The General Services Administration has authorized the use of th
2、is commercial item description for all federal agencies. 1. SCOPE. This commercial item description covers vertical, light-oil red, storage-type water heaters having thermal inputs not exceeding 280,000 British thermal units per hour (Btu/h) (82,040 Watts 0) and storage capacities up to 100 gallons
3、(gai) (379 liters (L) and constructed to Underwriters Laboratories, Inc. (UL) or American Society of Mechanical Engineers (ASME) requirements. Heaters are intended primarily for use in military residences and similar fhciiities. The heaters may be used in galleys, mess halls, showers, laundries, or
4、shops where thermal input up to 280,000 Btulh (82,040 W) will satis the demand. 2. CLASSIFICATION. Tanks fiirnished on the water heaters shall be of the following types and sizes (see table I and 7.2): Type I - Glass-lined steel. Type II - Stainless steel. Size 30 - 30-gallon (1 14 L) nominal storag
5、e capacity, with 0.5 gdons per hour (gph) Size 30 - 30-gallon (1 14 L) nominal storage capacity, with 0.75 gph (2.84 Wh) Size 40 - 40-gdon (151 L) nominal storage capacity, with 0.85 gph (3.22 Uh) (1.89 liters per hour (LAI) minimum firing rate. minimum firing rate. minimum firing rate. Beneficial c
6、omments, recommendations, additions, deletions, clarifications, etc. and any data which may improve this document should be sent to: Commanding Officer (Code 156), Naval Construction Battalion Center, 1000 23rd Avenue, Port Hueneme, CA 93043-4301. AMSC N/A FSC 4520 DISTRTBUTION STATEMENT A. Approved
7、 for public release; distribution is unlimited. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-50549 Size 50 - 50-gallon (189 L) nominal storage capacity, with 1.20 gph (4.54 Wh) Size 70 - 70-gdon (265 L) nominal storage capacity, with 1.35 gph
8、(5.1 1 Lh) Size 85 - 85-gallon (322 L) nominal storage capacity, with 1.45 gph (5.49 Wh) Size 100 - 100-gallon (379 L) nominal storage capacity, with 1.45 gph minimum firing rate. minimum firing rate. minimum firing rate. (5.49 Wh) minimum ring rate. 3. SALIENT CHARACTERISTICS. 3.1 DescriDtion. The
9、water heaters shall consist of an insulated vertical, steel, water storage tank, a light oil-fired combustion system not exceeding 280,000 Btuh (82,040 W) input capacity, and the operating and safety controls specified herein for completely automatic operation of the heaters for use in application r
10、equiring potable water. 3.2 Standard commercial product. The heaters shall, as a minimum, be in accordance with the requirements of this commercial item description and shall be the manufacturers standard commercial product. Additional or better features which are not specically prohibited by this c
11、ommercial item description but which are a part of the manufacturers standard commercial product, shall be included in the heaters being finished. A standard commercial product is a product which has been sold or is being currently offered for sale on the commercial market through advertisements or
12、manufacturers catalogs, or brochures, and represents the latest product model. 3.3 Codes and standards compliance. The water heaters shall comply with the requirements of a732 or ASME Boiler and Pressure Vessel Code, Section IV. The burner shall comply with UL296 (see 5.2). 3.4 Design. Steel for fab
13、rication of the storage tank shall be commercial quality sheet or plate, chemically constituted, and suitably processed to adapt the steel for application of glass (porcelain enamel) linings. Steel for tanks with glass (porcelain enamel) lining shall be suitable for exposure to fire and products of
14、combustion to which the tank will be exposed. Material in contact with potable water shall be nontoxic, and shall not impart odor, color, or taste to the contained water. The water heater package shall include: flue(s) that terminates in a flue coilar that permits attachment of a sheet metal smoke p
15、ipe; insulation which is held in place with a steel jacket; and a combustion chamber. The water heater shall be suitable for installation in an alcove or a closet as specified (see 7.2). The water heater shall be suitable for installation on non-combustible floors or combustible floors as specified
16、(see 7.2). When the water heaters are required for installation on combustible floors, installation instructions shall be provided on the unit for such application. Water heaters shall meet the capacity and performance requirements as follows: 2 Provided by IHSNot for ResaleNo reproduction or networ
17、king permitted without license from IHS-,-,-A-A-50549 Efficiency Percent a. For heaters 105,000 Btu/h (30,765 W) or less fhing 138,500 Btu/gal(496,924 HL) oil (No. 1 oil) recovery capacity shail be based on DOE regulations, CFR Title 10, Chapter II, Part 430 - Energy Conservation Program for Applian
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAAA505491996HEATERSWATERLIQUIDFUELOILFIREDSTORAGETYPENOTEXCEEDING280000BTUHINPUTCAPACITY 液体燃料 热水器 石油

链接地址:http://www.mydoc123.com/p-686270.html