CLC TS 50131-2-10-2014 Alarm systems - Intrusion and hold-up systems - Part 2-10 Intrusion detectors - Lock state contacts (magnetic).pdf
《CLC TS 50131-2-10-2014 Alarm systems - Intrusion and hold-up systems - Part 2-10 Intrusion detectors - Lock state contacts (magnetic).pdf》由会员分享,可在线阅读,更多相关《CLC TS 50131-2-10-2014 Alarm systems - Intrusion and hold-up systems - Part 2-10 Intrusion detectors - Lock state contacts (magnetic).pdf(36页珍藏版)》请在麦多课文档分享上搜索。
1、BSI Standards PublicationAlarm systems Intrusion and hold-up systemsPart 2-10: Intrusion detectors Lock state contacts (magnetic)PD CLC/TS 50131-2-10:2014National forewordThis Published Document is the UK implementation of CLC/TS 50131-2-10:2014.The UK participation in its preparation was entrusted
2、by TechnicalCommittee GW/1, Electronic security systems, to Subcommittee GW/1/1,Alarm components.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisions ofa contract. Users are responsi
3、ble for its correct application. The British Standards Institution 2014.Published by BSI Standards Limited 2014ISBN 978 0 580 82745 7ICS 13.320Compliance with a British Standard cannot confer immunity fromlegal obligations.This Published Document was published under the authority of theStandards Pol
4、icy and Strategy Committee on 31 May 2014.Amendments/corrigenda issued since publicationDate Text affectedPUBLISHED DOCUMENTPD CLC/TS 50131-2-10:2014TECHNICAL SPECIFICATION CLC/TS 50131-2-10 SPCIFICATION TECHNIQUE TECHNISCHE SPEZIFIKATION January 2014 CENELEC European Committee for Electrotechnical
5、Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung CEN-CENELEC Management Centre: Avenue Marnix 17, B - 1000 Brussels 2014 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No.
6、CLC/TS 50131-2-10:2014 E ICS 13.320 English version Alarm systems - Intrusion and hold-up systems - Part 2-10: Intrusion detectors - Lock state contacts (magnetic) Systmes dalarme - Systmes dalarme contre lintrusion et les hold-up - Partie 2-10: Dtecteurs dintrusion - Contact dtat de verrouillage (m
7、agntique) Alarmanlagen - Einbruch- und berfallmeldeanlagen - Teil 2-10: Einbruchmelder - Verschluss- und ffnungsberwachungskontakte (magnetisch) This Technical Specification was approved by CENELEC on 2013-12-02. CENELEC members are required to announce the existence of this TS in the same way as fo
8、r an EN and to make the TS available promptly at national level in an appropriate form. It is permissible to keep conflicting national standards in force. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia
9、, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. PD CLC/TS 50131-2-10:2
10、014CLC/TS 50131-2-10:2014 2 Contents Page Foreword . 4 Introduction . 5 1 Scope 6 2 Normative references 6 3 Terms, definitions and abbreviations 7 3.1 Terms and definitions . 7 3.2 Abbreviations . 8 4 Functional requirements. 9 4.1 Events . 9 4.2 Signals or messages . 9 4.3 Detection 10 4.4 Operati
11、onal requirements . 11 4.5 Tamper security . 11 4.6 Electrical requirements . 13 4.7 Environmental classification and conditions . 14 5 Marking, identification and documentation 15 5.1 Marking and/or identification . 15 5.2 Documentation 15 6 Testing 15 6.1 Generalities 15 6.2 General test condition
12、s. 15 6.3 Basic test of detection capability 16 6.4 Verification of detection performance . 16 6.5 Switch-on delay, time interval between signals, and indication of detection . 17 6.6 Tamper security . 17 6.7 Electrical tests . 19 6.8 Environmental classification and conditions . 20 6.9 Marking, ide
13、ntification and documentation 22 Annex A (normative) Dimensions EN 50131-2-3, Alarm systems Intrusion and hold-up systems Part 2-3: Requirements for microwave detectors; EN 50131-2-4, Alarm systems Intrusion and hold-up systems Part 2-4: Requirements for combined passive infrared and microwave detec
14、tors; EN 50131-2-5, Alarm systems Intrusion and hold-up systems Part 2-5: Requirements for combined passive infrared and ultrasonic detectors; EN 50131-2-6, Alarm systems Intrusion and hold-up systems Part 2-6: Opening contacts (magnetic); CLC/TS 50131-2-8, Alarm systems Intrusion and hold-up system
15、s Part 2-8: Intrusion detectors Shock detectors; CLC/FprTS 50131-2-9, Alarm systems Intrusion and hold-up systems Part 2-9: Intrusion detectors Active infrared beam detectors; CLC/TS 50131-2-10, Alarm systems Intrusion and hold-up systems Part 2-10: Intrusion detectors Lock state contacts (magnetic)
16、 the present document; EN 50131-2-7-1, Alarm systems Intrusion and hold-up systems Part 2-7-1: Intrusion detectors Glass break detectors (acoustic); EN 50131-2-7-2, Alarm systems Intrusion and hold-up systems Part 2-7-2: Intrusion detectors Glass break detectors (passive); EN 50131-2-7-3, Alarm syst
17、ems Intrusion and hold-up systems Part 2-7-3: Intrusion detectors Glass break detectors (active). Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CENELEC and/or CEN shall not be held responsible for identifying any or all such pat
18、ent rights. PD CLC/TS 50131-2-10:2014CLC/TS 50131-2-10:2014 5 Introduction This Technical Specification applies to lock state contacts (magnetic) used as part of intrusion and hold-up alarm systems (I BTD Basic Test of Detection capability; PD CLC/TS 50131-2-10:2014CLC/TS 50131-2-10:2014 9 DC Direct
19、 Current; EMC Electromagnetic Compatibility; RFID Radio Frequency Identification. 4 Functional requirements 4.1 Events The detector shall respond to events in accordance with Table 1 and as defined in this Clause 4. Table 1 Events to be processed and main functions to be provided by grade Event to b
20、e processed and functions to be provided Grade 1 2 3 4 Break distance exceeded M M M M Inside make distance M M M M Remote enable of detection indication aOp Op M M Connecting field interference Op Op M M Prevention and detection of access to the inside of the detector OpbMcMcMcRemoval from the moun
21、ting surfacedOp M M M Low power supply voltageeOp Op M M Total loss of external powerfM M M M Matched pairs, coding and encryptionOp Op M gM gKey M = Mandatory Op = Optional a Only required if detection indicator present. b Generation of a tamper signal for opening by normal means is not required. c
22、 Not required for sealed lock state contacts according to 4.5.2. d Mandatory for wire-free at grades 2, 3 and 4; mandatory for all grade 4 types, optional for wired grades 1, 2 and 3. e See 4.6.7. f See 4.6.6. g See 4.5.5. 4.2 Signals or messages The response to the signals or messages generated by
23、the detector is determined by the I at least one of these signals or messages (Intrusion or/and Tamper or/and Fault) shall be generated or an independent signal or message shall be generated. b Required only if the make and break distances are greater than twice the distances specified by the manufa
24、cturer (see 6.6.4); either intrusion AND fault signals or messages, OR an independent signal or message shall be generated. c See 4.6.7. d See 4.6.6. 4.3 Detection 4.3.1 Detection performance 4.3.1.1 Generalities The operating parameters of the detector shall be verified as specified by the manufact
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- CLCTS501312102014ALARMSYSTEMSINTRUSIONANDHOLDUPSYSTEMSPART210INTRUSIONDETECTORSLOCKSTATECONTACTSMAGNETICPDF

链接地址:http://www.mydoc123.com/p-629570.html