CLC TR 50600-99-3-2018 Information technology - Data centre facilities and infrastructures - Part 99-3 Guidance to the application of EN 50600 series.pdf
《CLC TR 50600-99-3-2018 Information technology - Data centre facilities and infrastructures - Part 99-3 Guidance to the application of EN 50600 series.pdf》由会员分享,可在线阅读,更多相关《CLC TR 50600-99-3-2018 Information technology - Data centre facilities and infrastructures - Part 99-3 Guidance to the application of EN 50600 series.pdf(32页珍藏版)》请在麦多课文档分享上搜索。
1、BSI Standards PublicationWB11885_BSI_StandardCovs_2013_AW.indd 1 15/05/2013 15:06Information technology - Data centre facilities and infrastructuresPart 99-3: Guidance to the application of EN 50600 seriesPD CLC/TR 50600-99-3:2018TECHNICAL REPORT RAPPORT TECHNIQUE TECHNISCHER BERICHT CLC/TR 50600-99
2、-3 August 2018 ICS 35.020; 35.110; 35.160 English Version Information technology - Data centre facilities and infrastructures - Part 99-3: Guidance to the application of EN 50600 series Technologies de linformation - Installations et infrastructures des centres de traitement de donnes - Partie 99-3:
3、 Recommandations relatives lapplication de la srie EN 50600 Informationstechnik - Einrichtungen und Infrastrukturen von Rechenzentren - Teil 99-3: Anleitung zur Anwendung der Normenreihe EN 50600 This Technical Report was approved by CENELEC on 2018-07-09. CENELEC members are the national electrotec
4、hnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania,
5、 Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung CEN-CENELEC Management Centre: Rue de la Science 23, B-1040
6、 Brussels 2018 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members. Ref. No. CLC/TR 50600-99-3:2018 E National forewordThis Published Document is the UK implementation of CLC/TR 50600-99-3:2018. The UK participation in its preparation was entrusted
7、to Technical Committee TCT/7, Telecommunications - Installation requirements.A list of organizations represented on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correc
8、t application. The British Standards Institution 2018 Published by BSI Standards Limited 2018ISBN 978 0 539 00082 5ICS 35.160; 35.020; 35.110Compliance with a British Standard cannot confer immunity from legal obligations.This Published Document was published under the authority of the Standards Pol
9、icy and Strategy Committee on 31 August 2018.Amendments/corrigenda issued since publicationDate Text affectedPUBLISHED DOCUMENTPD CLC/TR 50600-99-3:2018TECHNICAL REPORT RAPPORT TECHNIQUE TECHNISCHER BERICHT CLC/TR 50600-99-3 August 2018 ICS 35.020; 35.110; 35.160 English Version Information technolo
10、gy - Data centre facilities and infrastructures - Part 99-3: Guidance to the application of EN 50600 series Technologies de linformation - Installations et infrastructures des centres de traitement de donnes - Partie 99-3: Recommandations relatives lapplication de la srie EN 50600 Informationstechni
11、k - Einrichtungen und Infrastrukturen von Rechenzentren - Teil 99-3: Anleitung zur Anwendung der Normenreihe EN 50600 This Technical Report was approved by CENELEC on 2018-07-09. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Re
12、public, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United
13、 Kingdom. European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels 2018 CENELEC All rights of exploitation in any form and by any means
14、 reserved worldwide for CENELEC Members. Ref. No. CLC/TR 50600-99-3:2018 E PD CLC/TR 50600-99-3:2018CLC/TR 50600-99-3:2018 (E) 2 Contents Page European foreword . 3 Introduction . 4 1 Scope . 6 2 Normative references . 6 3 Terms, definitions and abbreviations . 6 3.1 Terms and definitions . 6 3.2 Ab
15、breviations 6 4 Principles 6 4.1 General . 6 4.2 Assessment of data centre design and operation using EN 50600 series 7 4.3 Availability class of a data centre . 8 4.4 Business risk analysis within EN 50600-1 8 5 Assessment of data centre design using EN 50600-2 series 10 5.1 General . 10 5.2 EN 506
16、00-2-1 Building construction 11 5.2.1 Overview . 11 5.2.2 Site assessment 11 5.2.3 Utility connections . 12 5.2.4 Structure of Building 12 5.3 EN 50600-2-2 Power supply and distribution 12 5.3.1 General 12 5.3.2 Power supply and distribution . 12 5.3.3 Energy efficiency enablement . 13 5.4 EN 50600-
17、2-3 Environmental control 14 5.5 EN 50600-2-4 Telecommunications cabling . 16 5.5.1 Overview . 16 5.5.2 Cable Class Requirements . 17 5.5.3 Cabinets and racks in computer room spaces 18 5.6 EN 50600-2-5 security systems 19 6 Assessment of data centre operation using EN 50600-3-1 . 20 6.1 General . 2
18、0 6.2 Process interface landscape 21 7 Assessment of data centre resource management using the EN 50600-4 series . 25 7.1 General . 25 7.2 Key Performance Indicators of the EN 50600-4 series 25 7.3 Total energy use of a data centre (EDC) . 25 7.4 Granularity of measurement . 26 7.5 EN 50600-4-2 - Po
19、wer Usage Effectiveness 26 7.6 EN 50600-4-3: Renewable Energy Factor . 27 Bibliography 28 PD CLC/TR 50600-99-3:2018CLC/TR 50600-99-3:2018 (E) 3 European foreword This document (CLC/TR 50600-99-3:2018) has been prepared by CLC/TC 215 “Electrotechnical aspects of telecommunication equipment”. Attentio
20、n is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CENELEC shall not be held responsible for identifying any or all such patent rights. This document has been prepared under a mandate given to CENELEC by the European Commission and the Europ
21、ean Free Trade Association. Regarding the structure of the EN 50600 series, see the Introduction. PD CLC/TR 50600-99-3:2018CLC/TR 50600-99-3:2018 (E) 4 Introduction The unrestricted access to internet-based information demanded by the information society has led to an exponential growth of both inte
22、rnet traffic and the volume of stored/retrieved data. Data centres are housing and supporting the information technology and network telecommunications equipment for data processing, data storage and data transport. They are required both by network operators (delivering those services to customer p
23、remises) and by enterprises within those customer premises. Data centres need to provide modular, scalable and flexible facilities and infrastructures to easily accommodate the rapidly changing requirements of the market. In addition, energy consumption of data centres has become critical both from
24、an environmental point of view (reduction of carbon footprint) and with respect to economic considerations (cost of energy) for the data centre operator. The implementation of data centres varies in terms of: a) purpose (enterprise, co-location, co-hosting, or network operator facilities); b) securi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- CLCTR506009932018INFORMATIONTECHNOLOGYDATACENTREFACILITIESANDINFRASTRUCTURESPART993GUIDANCETOTHEAPPLICATIONOFEN50600SERIESPDF

链接地址:http://www.mydoc123.com/p-629530.html