COE CEGS 02811-2000 UNDERGROUND SPRINKLER SYSTEMS NOTICE 1-10 (2000) INCORPORATED SPECIAL CHANGE (2000) INCORPORATED《地下喷洒系统 合并通知1-10(2000) 合并特殊变更(2000)》.pdf
《COE CEGS 02811-2000 UNDERGROUND SPRINKLER SYSTEMS NOTICE 1-10 (2000) INCORPORATED SPECIAL CHANGE (2000) INCORPORATED《地下喷洒系统 合并通知1-10(2000) 合并特殊变更(2000)》.pdf》由会员分享,可在线阅读,更多相关《COE CEGS 02811-2000 UNDERGROUND SPRINKLER SYSTEMS NOTICE 1-10 (2000) INCORPORATED SPECIAL CHANGE (2000) INCORPORATED《地下喷洒系统 合并通知1-10(2000) 合并特殊变更(2000)》.pdf(24页珍藏版)》请在麦多课文档分享上搜索。
1、TESTPDF*DEPARTMENT OF THE ARMY CEGS-02811 (November 1990)U.S. ARMY CORPS OF ENGINEERS -GUIDE SPECIFICATION FOR CONSTRUCTIONIncludes changes through Notice 10 (March 2000)Includes Special Change (Submittal Paragraph)(June/August 2000)Includes Special Change (Tailoring Options) (July 1998)Latest chang
2、e indicated by CHG tags*SECTION TABLE OF CONTENTSDIVISION 02 - SITE WORKSECTION 02811UNDERGROUND SPRINKLER SYSTEMS11/90PART 1 GENERAL1.1 REFERENCES1.2 PERFORMANCE REQUIREMENTS1.3 SUBMITTALS1.4 DELIVERY AND STORAGE1.5 FIELD MEASUREMENTSPART 2 PRODUCTS2.1 MATERIALS AND EQUIPMENT REQUIREMENTS2.1.1 Stan
3、dard Products2.1.2 Nameplates2.1.3 Extra Stock2.2 PIPING MATERIALS2.2.1 Copper Tubing and Associated Fittings2.2.2 Red Brass Pipe and Associated Fittings2.2.3 Galvanized Steel Pipe and Associated Fittings2.2.4 Polyvinyl Chloride (PVC) Pipe, Fittings and Solvent Cement2.2.4.1 PVC Pipe2.2.4.2 PVC Fitt
4、ings2.2.4.3 Solvent Cement2.2.5 Polyethylene (PE) Plastic Piping2.2.6 Dielectric Fittings2.2.7 Emitter Hose and Distribution Tubing2.3 SPRINKLER AND EMITTER HEADS2.3.1 Pop-Up Spray Heads2.3.1.1 General Requirements2.3.1.2 Shrubbery Sprinkler Heads2.3.2 Rotary Pop-Up Sprinklers2.3.3 Bubbler Sprinkler
5、 Heads2.3.4 Surface Connected Lawn Sprinkler Heads2.3.5 Emitter HeadsSECTION 02811 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-TESTPDF2.4 VALVES2.4.1 Gate Valves, Less than 80 mm (3 Inches) 3 Inches2.4.2 Gate Valves, 80 mm (3 Inches) 3 Inch
6、es and Larger2.4.3 Angle Valves, Less Than 65 mm (2-1/2 Inches) 2-1/2 Inches2.4.4 Angle Valves, 65 mm (2-1/2 Inches) 2-1/2 Inches and Larger2.4.5 Quick Coupling Valves2.4.6 Remote Control Valves, Electrical2.4.7 Drain Valves2.4.7.1 Manual Valves2.4.7.2 Automatic Valves2.4.8 Pressure Regulating Maste
7、r Valve2.4.9 Backflow Preventers2.4.9.1 Pressure Type Vacuum Breaker2.4.9.2 Reduced Pressure Type Backflow Preventers2.5 ACCESSORIES AND APPURTENANCES2.5.1 Valve Keys for Manually Operated Valves2.5.2 Valve Boxes and Concrete Pads2.5.2.1 Valve Boxes2.5.2.2 Concrete Pads2.5.3 Pressure Gauges2.5.4 Ser
8、vice Clamps2.5.5 Water Hammer Arresters2.5.6 Emitter Head Accessories2.5.6.1 Strainer2.5.6.2 Pressure Regulator2.5.6.3 Riser Adapters2.5.6.4 Tubing Stakes2.5.6.5 Emitter Outlet Check Valve (Bug Cap)2.5.6.6 Access Sleeve2.5.6.7 Closure Caps2.6 AUTOMATIC CONTROLLERS, ELECTRICAL2.7 ELECTRICAL WORK2.8 C
9、ONCRETE MATERIALS2.9 WATER SUPPLY MAIN MATERIALS2.10 INSULATING JOINTSPART 3 EXECUTION3.1 INSTALLATION3.1.1 Trenching3.1.2 Piping System3.1.2.1 Cover3.1.2.2 Clearances3.1.2.3 Minimum Slope3.1.3 Piping Installation3.1.3.1 Polyvinyl Chloride (PVC) Pipe3.1.3.2 Soldered Copper Tubing3.1.3.3 Threaded Bra
10、ss or Galvanized Steel Pipe3.1.3.4 Insulating Joints3.1.4 Installation of Valves3.1.4.1 Manual Valves3.1.4.2 Automatic Valves3.1.4.3 Drain Valves3.1.5 Sprinklers and Quick Coupling Valves3.1.6 Installation of Drip Irrigation System3.1.6.1 Emitter Hose3.1.6.2 Emitter Heads3.1.6.3 Tubing Stakes3.1.7 B
11、ackflow PreventersSECTION 02811 Page 2Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-TESTPDF3.1.7.1 Pressure Type Vacuum Breaker3.1.7.2 Reduced Pressure Type3.1.8 Control Wire and Conduit3.1.8.1 Wires3.1.8.2 Loops3.1.8.3 Expansion and Contraction3.1
12、.8.4 Splices3.1.9 Automatic Controller3.1.10 Thrust Blocks3.1.11 Backfill3.1.11.1 Minimum Cover3.1.11.2 Restoration3.1.12 Adjustment3.1.13 Disinfection3.1.14 Cleaning of Piping3.2 FIELD TESTS3.2.1 Hydrostatic Pressure Test3.2.2 Leakage Tests3.2.3 Operation Test3.3 FRAMED INSTRUCTIONS3.4 FIELD TRAINI
13、NG3.5 CLEANUP- End of Section Table of Contents -SECTION 02811 Page 3Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-TESTPDF*DEPARTMENT OF THE ARMY CEGS-02811 (November 1990)U.S. ARMY CORPS OF ENGINEERS -GUIDE SPECIFICATION FOR CONSTRUCTIONIncludes c
14、hanges through Notice 10 (March 2000)Includes Special Change (Submittal Paragraph)(June/August 2000)Includes Special Change (Tailoring Options) (July 1998)Latest change indicated by CHG tags*SECTION 02811UNDERGROUND SPRINKLER SYSTEMS11/90*NOTE: This guide specification covers the requirements for un
15、derground sprinkler irrigation systems. This guide specification is to be used in the preparation of project specifications in accordance with ER 1110-1-8155.Comments and suggestions on this guide specification are welcome and should be directed to the proponent of the specification. A listing of pr
16、oponents, including their organization designation and telephone number, is at URL http:/www.hnd.usace.army.mil/techinfo/index.htm, and an electronic feedback page for submission of recommended changes is available at the same address. Use of electronic communication is encouraged.This guide specifi
17、cation includes tailoring options for copper tubing, red brass pipe, galvanized steel pipe, polyvinyl chloride (PVC) pipe, and polyethylene (PE) plastic pipe. Selection or deselection of a tailoring option will include or exclude that option in the section, but editing the resulting section to fit t
18、he project is still required.*PART 1 GENERAL*NOTE: Irrigation system requirements depend upon rainfall factors for the project area, plant selections, the quality of growth desired, and budgetary constraints. The area factors will be determined by a registered landscape professional. Reference is ma
19、de to TM 5-803-13. While the design SECTION 02811 Page 4Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-TESTPDFof a system with pop-up heads may be justified in some geographic areas, bubbler type systems may be required in areas where water conserva
20、tion methods are being practiced. If source of water supply is from base water main through a service line and water meter, determine amount of water available for irrigation system from static pressure at point of connection to water main. In many cases, water supply is adequate for short durations
21、 only. The amount of water required is determined from the type of turf to be irrigated, climate, terrain, and soil conditions. System piping layout, pipe sizes, and selection and spacing of heads and emitters must provide the required amount of water and complete coverage of the irrigated areas. Pr
22、ovide valves to allow irrigation of each area separately.*1.1 REFERENCESThe publications listed below form a part of this specification to the extent referenced. The publications are referred to in the text by the basic designation only.AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM)ASTM A 53 (199
23、9b) Pipe, Steel, Black and Hot-Dipped, Zinc-Coated, Welded and SeamlessASTM B 32 (1996) Solder MetalASTM B 43 (1998) Seamless Red Brass Pipe, Standard SizesASTM B 88 (1996) Seamless Copper Water TubeASTM B 88M (1996) Seamless Copper Water Tube (Metric)ASTM D 1785 (1999) Poly(Vinyl Chloride) (PVC) Pl
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- COECEGS028112000UNDERGROUNDSPRINKLERSYSTEMSNOTICE1102000INCORPORATEDSPECIALCHANGE2000INCORPORATED 地下

链接地址:http://www.mydoc123.com/p-620631.html