1、CEPT T/CS*49-05*E = 232b414 000490L 2 O Page 1 (3 TCS49-05 E Recommendation T/CS 49-05 (Vienna 1982, revised in Montpellier 1984) SYSTEM L1 MULTIFREQUENCY PUSH-BUTTON UNIDIRECTIONAL CALL CONTROL SIGNALLING PROCEDURES Recommendation proposed by Working Group T/WG 1 i “Switching and Signalling” (CS) R
2、evised text of the Recommendation adopted by the “Telecommunications ” Commission. “The European Conference of Postal and Telecommunications Administrations, considering - that multifrequency push-button (MFPB) subscribers line signalling may provide faster call Set-up than decadic - that equipment
3、located at subscribers premises and used in private networks more and more employs MFPB - that MFPB interregister signals as specified in Recommendation T/CS 49-04 i may be used either in the forward pulsing signalling, signalling techniques, direction only or in both the forward and the backward di
4、rection, recommends to the members that the call control signalling procedures specified below are used, when MFPB interregister signalling is applied in the forward direction only (unidirectional) between private automatic branch exchanges (PABXs), in different countries.” 1. GENERAL 1.1. Field of
5、application In the System L1 MFPB unidirectional call control signalling procedures, MFPB interregister signals are only used in the forward direction of call Set-up, e.g. the MFPB character set of the 12-button array according to Recommendation T/CS 46-02 2 is used for address signalling and servic
6、e control. The signalling procedures specified in this Recommendation cover the standard call Set-up and call clear-down. Enhancements providing the interchange of additional information are given as options, e.g. for recall and intrusion. 1.2. Signals On international leased lines, System L1 MFPB u
7、nidirectional, in accordance with Recommendation T/CS 49-04 i, is used in conjunction with System L1 line signalling as specified in Recommendation The signals actually used with System L1 MFPB call control procedures contained in this Recommendation are given in Table 1 (T/CS 49-05). The meanings o
8、f the signals comply with Recommendation T/CS 41-01 4. The requirements for the transmission of the signals are set-out in Recommendations T/CS 49-01 3, T/CS 49-02 5 and T/CS 49-04 i. The use of the address-complete signal and the answer signal is subject to options 2 and 3, respectively. The three
9、signals, address-complete, extension-free; address-complete, extension-busy and busy-extension- changed-to-free, may be chosen instead of the address-complete signal (option 4). If the signals intrusion and end-of-intrusion are used (option 5), then option 3 must be applied. The four recall signals
10、represent option 6. All options must be mutually agreed upon by the parties involved. Option 1 provides for the use of the seizing-acknowledgement signal instead of the proceed-to-send signal. T/CS 49-01 3. I. Edition of September 15, 1986 CEPT T/CS*49-05*E 2326434 0004402 4 = 1 TICS 49-05 E Page 2
11、I Signais Seizing Proceed-to-send Seizing-acknowledgement Address Clear-request Address-complete Answer Clear-forward Clear-back Cleared Address-complete, extension-free Address-complete, extension-busy Busy-extension-changed-to-free Intrusion End-of-intrusion Forward-service-request-recall Backward
12、-service-request-recall Backward-link-recall Proceed-to-send-on-recall Reconnect Option I Recommendation T/CS 49-01 T/CS 49-02 T/CS 49-01 T/CS 49-04 T/CS 49-01 TICS 49-02 T/CS 49-01 T/CS 49-01 T/CS 49-01 T/CS 49-01 T/CS 49-02 TICS 49-02 T/CS 49-02 T/CS 49-01 T/CS 49-01 T/CS 49-01 T/CS 49-01 T/CS 49-
13、01 T/CS 49-02 TICS 49-02 Legend: 1, 2, 3, 4, 5, 6: option I, 2, 3, 4, 5, 6. M: Mandatory. Table 1 (T/CS 49-05). Signals used in System LI MFPB unidirectional call control signalling. Note I; If option is provided, the seizing-acknowledgement procedure must be used instead of the proceed-to-send proc
14、edure. 2. SIGNALLING PROCEDURES 2.1. General 2.1.1. The signalling procedures are described by means of SDL diagrams in accordance with CCITT Recom- mendations 2.101 7, 2.102 8 and 2.104 9, and narrative comments. Table 4 in Recommendation T/CS 49-04 i includes abbreviations used in the SDL diagrams
15、. Note: The SDL diagrams are included in this Recommendation to assist in the understanding of the technical text and must only be used in association with the text. Where a service demand requires inter-PABX MFPB signalling, the request is handled by the responding PABX on an accept or reject basis
16、, depending upon the availability of the service at that PABX. 2.2. Set-up and clear-down of standard calls 2.2.1, Figures 1, 2 and 9 (T/CS 49-05) show the signalling sequences at the outgoing and incoming PABX line interfaces for Set-up and clear-down of standard calls. Following the proceed-to-sen
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- CEPTTCS4905E1986SYSTEML1MFPBUNDIRECTIONALCALLCONTROLSIGNALLINGPROCEDURES 系统 L1 按键 单向 呼叫 控制 程序 PDF

链接地址:http://www.mydoc123.com/p-593063.html