BS ISO 2926-2013 Aluminium oxide used for the production of primary aluminium Particle size analysis for the range 45 $GMm to 150 $GMm Method using electroformed sieves《主要用于铝生产的氧化铝.pdf
《BS ISO 2926-2013 Aluminium oxide used for the production of primary aluminium Particle size analysis for the range 45 $GMm to 150 $GMm Method using electroformed sieves《主要用于铝生产的氧化铝.pdf》由会员分享,可在线阅读,更多相关《BS ISO 2926-2013 Aluminium oxide used for the production of primary aluminium Particle size analysis for the range 45 $GMm to 150 $GMm Method using electroformed sieves《主要用于铝生产的氧化铝.pdf(22页珍藏版)》请在麦多课文档分享上搜索。
1、BSI Standards PublicationBS ISO 2926:2013Aluminium oxide used for the production of primary aluminiumParticle size analysis for the range 45 m to 150 m Method using electro-formed sievesBS ISO 2926:2013 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of ISO 2926:2013.
2、 It supersedes BS ISO 2926:2005 which is withdrawn.The UK participation in its preparation was entrusted to Technical Committee CII/24, Raw materials for the aluminium industry.A list of organizations represented on this committee can be obtained on request to its secretary.This publication does not
3、 purport to include all the necessary provisions of a contract. Users are responsible for its correct application. The British Standards Institution 2013.Published by BSI Standards Limited 2013ISBN 978 0 580 66584 4 ICS 71.100.10 Compliance with a British Standard cannot confer immunity from legal o
4、bligations.This British Standard was published under the authority of the Standards Policy and Strategy Committee on 30 September 2013.Amendments/corrigenda issued since publicationDate T e x t a f f e c t e dBS ISO 2926:2013 ISO 2013Aluminium oxide used for the production of primary aluminium Parti
5、cle size analysis for the range 45 m to 150 m Method using electroformed sievesOxyde daluminium utilis pour la production daluminium primaire Analyse granulomtrique dans la gamme 45 m 150 m Mthode par emploi de tamis lectroformsINTERNATIONAL STANDARDISO2926Third edition2013-09-01Reference numberISO
6、2926:2013(E)BS ISO 2926:2013ISO 2926:2013(E)ii ISO 2013 All rights reservedCOPYRIGHT PROTECTED DOCUMENT ISO 2013All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized otherwise in any form or by any means, electronic or mechanical, including photoc
7、opying, or posting on the internet or an intranet, without prior written permission. Permission can be requested from either ISO at the address below or ISOs member body in the country of the requester.ISO copyright officeCase postale 56 CH-1211 Geneva 20Tel. + 41 22 749 01 11Fax + 41 22 749 09 47E-
8、mail copyrightiso.orgWeb www.iso.orgPublished in SwitzerlandBS ISO 2926:2013ISO 2926:2013(E) ISO 2013 All rights reserved iiiContents PageForeword ivIntroduction v1 Scope . 12 Normative references 13 Principle 14 Apparatus . 15 Procedure. 25.1 Sample preparation 25.2 Preparation of test sieves . 25.
9、3 Determination . 26 Calculation of results . 37 Test report . 38 Precision . 4Annex A (informative) Example of calculation of size analysis . 5Annex B (informative) Determination and use of effective aperture . 6Annex C (informative) Results of interlaboratory test programme . 7Annex D (informative
10、) Ultrasonic cleaning of sieves . 9Bibliography .10BS ISO 2926:2013ISO 2926:2013(E)ForewordISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out throug
11、h ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborat
12、es closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.The procedures used to develop this document and those intended for its further maintenance are described in the ISO/IEC Directives, Part 1. In particular the different approval cri
13、teria needed for the different types of ISO documents should be noted. This document was drafted in accordance with the editorial rules of the ISO/IEC Directives, Part 2 (see www.iso.org/directives).Attention is drawn to the possibility that some of the elements of this document may be the subject o
14、f patent rights. ISO shall not be held responsible for identifying any or all such patent rights. Details of any patent rights identified during the development of the document will be in the Introduction and/or on the ISO list of patent declarations received (see www.iso.org/patents).Any trade name
15、 used in this document is information given for the convenience of users and does not constitute an endorsement.For an explanation on the meaning of ISO specific terms and expressions related to conformity assessment, as well as information about ISOs adherence to the WTO principles in the Technical
16、 Barriers to Trade (TBT) see the following URL: Foreword - Supplementary informationThe committee responsible for this document is ISO/TC 226, Materials for the production of primary aluminium.This third edition cancels and replaces the second edition (ISO 2926:2005), which has been technically revi
17、sed to reflect modern industry practice. The major changes are: recommended effective aperture tolerance limits have been added; sieves are cleaned by brushing rather than using an ultrasonic bath; the mass of sample to be sieved is 50 g;iv ISO 2013 All rights reservedBS ISO 2926:2013ISO 2926:2013(E
18、)IntroductionThis International Standard is based on AS 2879.6-1995 prepared by Standards Australia. ISO 2013 All rights reserved vBS ISO 2926:2013BS ISO 2926:2013Aluminium oxide used for the production of primary aluminium Particle size analysis for the range 45 m to 150 m Method using electroforme
19、d sieves1 ScopeThis International Standard specifies a dry sieve method using electroformed sieves for determining the mass distribution of the particle sizes in aluminium oxide used for the production of primary aluminium.This method is applicable to calcined aluminium oxide containing a maximum of
20、 20 % mass fraction of particles having a mean diameter exceeding 150 m, and containing a maximum of 15 % mass fraction of particles having a mean diameter less than 45 m.This method is not applicable to the use of woven wire sieves.2 Normative referencesThe following documents, in whole or in part,
21、 are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.ISO 3310-3, Test sieves Technical requirements and te
22、sting Part 3: Test sieves of electroformed sheets3 PrincipleA test portion of the crude sample is sieved mechanically through electroformed sieves.Each of the separate fractions is weighed on the sieve, and a cumulative mass of material retained on each sieve aperture size is calculated.4 Apparatus4
23、.1 Test sieves, each including a sieving medium (screen) and a frame.The frames shall be cylindrical, having nominal diameters of 200 mm and heights between 50 mm and 75 mm. A lid and a bottom receiver shall be included. The sieves, lid and bottom receiver shall be capable of being fitted together t
24、ightly to form a series of test sieves1).The screens shall be constructed of smooth electroformed sheet having square openings. The aperture tolerances shall be in accordance with ISO 3310-3.The sieve apertures shall have nominal sizes of 150 m, 106 m, 75 m, 53 m and 45 m. Refer to Annex B for effec
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSISO29262013ALUMINIUMOXIDEUSEDFORTHEPRODUCTIONOFPRIMARYALUMINIUMPARTICLESIZEANALYSISFORTHERANGE45GMMTO150GMMMETHODUSINGELECTROFORMEDSIEVES

链接地址:http://www.mydoc123.com/p-586928.html