BS IEC 60287-3-3-2007 Electric cables - Calculation of the current rating - Sections on operating conditions - Cables crossing external heat sources《电缆 额定电流的计算 运行条件章节 横越外部热源的电缆》.pdf
《BS IEC 60287-3-3-2007 Electric cables - Calculation of the current rating - Sections on operating conditions - Cables crossing external heat sources《电缆 额定电流的计算 运行条件章节 横越外部热源的电缆》.pdf》由会员分享,可在线阅读,更多相关《BS IEC 60287-3-3-2007 Electric cables - Calculation of the current rating - Sections on operating conditions - Cables crossing external heat sources《电缆 额定电流的计算 运行条件章节 横越外部热源的电缆》.pdf(18页珍藏版)》请在麦多课文档分享上搜索。
1、 g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58Part 3-3: Sections on operating conditions Cables crossing external heat sourcesICS 29.060.20Electr
2、ic cables Calculation of the current rating BRITISH STANDARDBS IEC 60287-3-3:2007BS IEC 60287-3-3:2007This British Standard was published under the authority of the Standards Policy and Strategy Committee on 29 June 2007 BSI 2007ISBN 978 0 580 55214 4Amendments issued since publicationAmd. No. Date
3、CommentsThis publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunity from legal obligations.National forewordThis British Standard was published by BSI. It is the U
4、K implementation of IEC 60287-3-3:2007.The UK participation in its preparation was entrusted by Technical Committee GEL/20, Electric cables, to Subcommittee GEL/20/16, Medium/high voltage cables.A list of organizations represented on this committee can be obtained on request to its secretary.INTERNA
5、TIONAL STANDARD IEC60287-3-3First edition2007-05Electric cables Calculation of the current rating Part 3-3: Sections on operating conditions Cables crossing external heat sources Reference number IEC/CEI 60287-3-3:2007 BS IEC 60287-3-3:2007 BS IEC 60287-3-3:2007 2 CONTENTS INTRODUCTION.3 1 Scope 4 2
6、 Normative references .4 3 Symbols .4 4 Description of method.5 4.1 General description .5 4.2 Single source crossing.7 4.3 Several crossings 8 4.4 Rating of two crossing cables.9 Annex A (informative) Example calculation .10 Annex B (informative) Temperature rise calculation at any point along the
7、route15 Figure 1 Illustration of a heat source crossing rated cable.6 Figure A.1 Cable configuration .10 Table A.1 Cable and installation data .11 Table A.2 Rating factor for the 300 mm XLPE 10 kV circuit12 Table A.3 Rating factor for the 400 mm 132 kV cable.13 Table A.4 Rating factors.14 3 BS IEC 6
8、0287-3-3:2007 INTRODUCTION In the IEC 60287 series, Part 1 provides general formulae for ratings and power losses of electric cables. Part 2 presents formulae for thermal resistance, with Part 2-1 providing general calculation methods for thermal resistance. Part 2-1 provides calculation methods for
9、 dealing with groups of buried cables (see 2.2.3). These methods assume that the cables are laid in parallel and hence every cable acts as a parallel line heat source. This Part 3-3 deals with the crossing of a cable, at right angles or obliquely with another cable, and, more generally, with any lin
10、ear heat source, such as steam pipes. When heat sources are installed in the vicinity of a cable, the permissible current-carrying capacity of the cable should be reduced to avoid overheating. But applying formulae that are valid for parallel routes would overestimate the thermal influence of the cr
11、ossing heat source on the cable. In this standard a general simplified method is provided to estimate the reduction of the permissible current-carrying capacity of a cable crossed by heat sources. Every cable and heat source is assumed to be laid horizontally. BS IEC 60287-3-3:2007 4 ELECTRIC CABLES
12、 CALCULATION OF THE CURRENT RATING Part 3-3: Sections on operating conditions Cables crossing external heat sources 1 Scope This part of IEC 60287 describes a method for calculating the continuous current rating factor for cables of all voltages where crossings of external heat sources are involved.
13、 The method is applicable to any type of cable. The method assumes that the entire region surrounding a cable, or cables, has uniform thermal characteristics and that the principle of superposition applies. The principle of superposition does not strictly apply to touching cables and hence the calcu
14、lation method set out in this standard will produce an optimistic result if applied to touching cables. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the
15、latest edition of the referenced document (including any amendments) applies. IEC 60287 (all parts), Electric cables Calculation of the current rating 3 Symbols A Conductor cross-sectional area mm DF Ratio of the permissible current when taking into account the presence of crossing heat sources to t
16、he permissible current of the isolated cable (derating factor) - I Maximum permissible current of the rated cable when isolated A L Depth of laying, to cable axis, of the rated cable m Lh Depth of laying of heat source h m N Number of intervals in the spatial discretization for the calculations 1T T
17、hermal resistance per core between conductor and sheath Km/W2T Thermal resistance between sheath and armour Km/W3T Thermal resistance of external serving Km/W4T Thermal resistance of surrounding medium (ratio of cable surface temperature rise above ambient to the losses per unit length) Km/WmhT Mutu
18、al thermal resistance between cable and heat source Km/WT Equivalent thermal resistance of cable per conductor Km/WrT Total thermal resistance of cable per conductor Km/WLT Thermal longitudinal resistance of a conductor K/m/W dW Dielectric losses per unit length per phase W/m 5 BS IEC 60287-3-3:2007
19、 gW Heat generated in the rated cable, due to losses in a conductor, assuming a conductor temperature of 20 C W/m hW Heat generated by external heat source h W/m k Number of heat sources, crossing the rated cable - rz Location of the hottest point on the route of the rated cable(z co-ordinate) when
20、several crossings are considered m zmaxDistance along the cable route from the hottest point to the point where longitudinal heat flux is negligible m n Number of cores - 20 Temperature coefficient of electrical resistivity at 20 C, per Kelvin K-1 Crossing angle Radian Attenuation factor m-1 1 Ratio
21、 of the total losses in metallic sheaths to the total conductor losses(sheath/screen loss factor) - 2 Ratio of the total losses in armour to the total conductor losses (armour loss factor) - Soil thermal resistivity Km/Wcr Conductor thermal resistivity Km/Wmax Maximum permissible conductor temperatu
22、re C d Conductor temperature rise due to dielectric losses K max Maximum permissible conductor temperature rise above ambient K ()z Temperature rise of the conductor(s) of the rated cable, due to crossing heat sources, at the point z in the cable route K (0) Temperature rise of the conductor(s) of t
23、he rated cable, due to crossing heat sources, at the hottest point in the cable route K ()uhzTemperature rise of the conductor(s) of the rated cable, due to the heat source, h, without taking into account longitudinal heat flux K W Incremental heat generated due to change of conductor resistance W/K
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSIEC60287332007ELECTRICCABLESCALCULATIONOFTHECURRENTRATINGSECTIONSONOPERATINGCONDITIONSCABLESCROSSINGEXTERNALHEATSOURCES

链接地址:http://www.mydoc123.com/p-582909.html