BS EN 61223-2-5-1995 Evaluation and routine testing in medical imaging departments - Constancy tests - Method for image display devices《医用成像部门常规试验评定 恒定试验 图像显示装置方法》.pdf
《BS EN 61223-2-5-1995 Evaluation and routine testing in medical imaging departments - Constancy tests - Method for image display devices《医用成像部门常规试验评定 恒定试验 图像显示装置方法》.pdf》由会员分享,可在线阅读,更多相关《BS EN 61223-2-5-1995 Evaluation and routine testing in medical imaging departments - Constancy tests - Method for image display devices《医用成像部门常规试验评定 恒定试验 图像显示装置方法》.pdf(28页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS EN 61223-2-5:1995 BS7725-2.5: 1995 IEC1223-2-5: 1994 Evaluation and routine testing in medical imaging departments Part 2: Constancy tests Section 2.5 Method for image display devices The European Standard EN61223-2-5:1994 has the status of a BritishStandard UDC 615.84:778.2:620.
2、1BSEN61223-2-5:1995 This BritishStandard, having been prepared under the directionof the Sector Board forHealth and Environment, waspublished under the authorityofthe Standards Boardand comesinto effect on 15February1995 BSI 01-2000 The following BSI references relate to the work on this standard: C
3、ommittee reference HCC/73 Draft for comment 93/504903 DC ISBN 0 580 23748 6 Committees responsible for this BritishStandard The preparation of this BritishStandard was entrusted to Technical Committee HCC/73, Interchangeable X-ray components, upon which the following bodies were represented: British
4、 Institute of Radiology College of Radiographers Department of Health Institute of Physical Sciences in Medicine (IPSM) Royal College of Radiologists Society of X-ray Technology Amendments issued since publication Amd. No. Date CommentsBSEN61223-2-5:1995 BSI 01-2000 i Contents Page Committees respon
5、sible Inside front cover National foreword ii Foreword 2 Text of EN 61223-2-5 3 List of references Inside back coverBSEN61223-2-5:1995 ii BSI 01-2000 National foreword This BritishStandard has been prepared by Technical Committee HCC/73, Interchangeable X-ray components, and is the English language
6、version of EN61223-2-5:1994 Evaluation and routine testing in medical imaging departments Part2-5: Constancy tests Image display devices, published by the European Committee for Electrotechnical Standardization (CENELEC). It is identical with IEC1223-2-5:1994 published by the International Electrote
7、chnical Commission (IEC). A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Cross-reference
8、s Publication referred to Corresponding BritishStandard IEC788:1984 BS6641:1985 Glossary of medical radiology terms BS7725 Evaluation and routine testing in medical imaging departments IEC1223-1:1993 Part1:1994 General Part2 Constancy tests IEC1223-2-1:1993 Section2.1:1994 Method for film processors
9、 IEC1223-2-2:1993 Section2.2:1994 Method for radiographic cassettes and film changers and film-screen contact and relative sensitivity of the screen-cassette assembly IEC1223-2-3:1993 Section2.3:1994 Method for darkroom safelight conditions IEC1223-2-4:1994 Section2.4:1994 Method for hard copy camer
10、as Summary of pages This document comprises a front cover, an inside front cover, pagesi andii, theEN title page, pages2 to22, an inside back cover and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment
11、table on the inside front cover.EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 61223-2-5 June 1994 UDC 615.84:778.2:620.1 Descriptors: Electromedical equipment, computed tomography, medical imaging, constancy test, evaluation testing, routine testing English version Evaluation and routine test
12、ing in medical imaging departments Part2-5: Constancy tests Image display devices (IEC1223-2-5:1994) Essais dvaluation et de routine dans les services dimagerie mdicale Partie2-5: Essais de constance Dispositifsdevisualisation des images (CEI1223-2-5:1994) Bewertung und routinemige Prfung in Abteilu
13、ngen fr medizinische Bildgebung Teil2-5: Konstanzprfungen Bildwiedergabegerte (Monitore) (IEC1223-2-5:1994) This European Standard was approved by CENELEC on1994-03-08. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this Europe
14、an Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (Engli
15、sh, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, B
16、elgium, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and UnitedKingdom. CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr
17、Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B-1050 Brussels 1994 Copyright reserved to all CENELEC members Ref. No. EN61223-2-5:1994 EEN61223-2-5:1994 2 BSI 01-2000 Foreword The text of document62B(CO)106, as prepared by Sub-Committee62B, Diagnostic imaging equipment, of IEC T
18、echnical Committee62, Electrical equipment in medical practice, was submitted to the IEC-CENELEC parallel vote in May1993. The reference document was approved by CENELEC as EN61223-2-5 on8 March1994. The following dates were fixed: Annexes designated “normative” are part of the body of the standard.
19、 Annexes designated “informative” are given only for information. In this standard, Annex A and Annex ZA are normative andAnnex B,Annex C,Annex D,Annex E andAnnex F are informative. Contents Page Foreword 2 Introduction 3 1 Scope and object 3 1.1 Scope 3 1.2 Object 3 2 Normative references 3 3 Termi
20、nology 4 3.1 Degree of requirements 4 3.2 Use of terms 4 3.3 Definitions 4 4 General aspects of CONSTANCY TESTS 4 4.1 General conditions affecting test procedures 4 4.2 Establishment of BASELINE VALUES 5 4.3 Frequency of CONSTANCY TESTS 5 4.4 Identification of equipment, instrumentation and test con
21、ditions 5 4.5 Measured functional parameters 5 5 Test methods 5 5.1 Summary 5 5.2 Test equipment 5 5.3 Test procedure 6 5.4 Data evaluation 9 Page 5.5 Criteria to be applied 9 5.6 Test report 10 5.7 Action to be taken 10 5.8 Frequency of testing 10 6 Statement of compliance 10 Annex A (normative) Te
22、rminology Index ofterms 17 Annex B (informative) Example of a form forthestandardized test report 18 Annex C (informative) Guidance on action tobetaken 20 Annex D (informative) Rationale 20 Annex E (informative) Bibliography Referencetest pattern 21 Annex F (informative) IMAGE DISPLAY DEVICES inwork
23、stations: Environmental conditions 22 Annex ZA (normative) Other international publications quoted in this standard with thereferences of the relevant European publications 22 Figure 1 Schematic representation of a testpattern used to check the constancy with respect to grey-scale reproduction 11 Fi
24、gure 2 Schematic representation of a testpattern used to check the constancy with respect to geometry and line structure 12 Figure 3 Schematic representation of a crosshatched pattern used to carry out measurements with respect to geometry 13 Figure 4 Schematic representation of a testpattern used t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN61223251995EVALUATIONANDROUTINETESTINGINMEDICALIMAGINGDEPARTMENTSCONSTANCYTESTSMETHODFORIMAGEDISPLAYDEVICES

链接地址:http://www.mydoc123.com/p-577120.html