1、BS EN 15089:2009ICS 13.230NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBRITISH STANDARDExplosion isolationsystemsThis British Standardwas published under theauthority of the StandardsPolicy and StrategyCommittee on 30 April2009 BSI 2009ISBN 978 0 580 54835 2Amendments/corrig
2、enda issued since publicationDate CommentsBS EN 15089:2009National forewordThis British Standard is the UK implementation of EN 15089:2009.The UK participation in its preparation was entrusted to TechnicalCommittee FSH/23, Fire precautions in industrial and chemical plant.A list of organizations rep
3、resented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisionsof a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunityfrom legal obligations.BS EN 15089:
4、2009EUROPEAN STANDARDNORME EUROPENNEEUROPISCHE NORMEN 15089March 2009ICS 13.230English VersionExplosion isolation systemsSystme disolation dexplosion Explosions-EntkopplungssystemeThis European Standard was approved by CEN on 7 February 2009.CEN members are bound to comply with the CEN/CENELEC Inter
5、nal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the CEN Management Centre or to any CEN member
6、.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as theofficial versions.CEN members are
7、 the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,Romania, Slovakia, Slovenia, Spain, Sweden, Switzerla
8、nd and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMIT EUROPEN DE NORMALISATIONEUROPISCHES KOMITEE FR NORMUNGManagement Centre: Avenue Marnix 17, B-1000 Brussels 2009 CEN All rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 15089:2
9、009: EBS EN 15089:2009EN 15089:2009 (E) 2 Contents Page Foreword 4 1 Scope 5 2 Normative references 5 3 Terms and definitions .6 4 Explosion isolation systems 8 4.1 General 8 4.2 Isolation types 8 4.2.1 Passive isolation type .8 4.2.2 Active isolation type 8 5 Requirements of explosion isolation com
10、ponents 8 5.1 General 8 5.2 Detection devices 9 5.2.1 General 9 5.2.2 Optical detection 9 5.2.3 Pressure detection.9 5.2.4 Other actuation 9 5.3 Indicating equipment (IE) and control and indicating equipment (CIE) .9 5.3.1 General 9 5.3.2 Indicating equipment .9 5.3.3 Control and indicating equipmen
11、t .9 5.4 Safety integrity of control and indicating equipment (CIE) 10 5.4.1 General . 10 5.4.2 Measures to avoid and control systematic faults . 10 5.4.3 Control of electric connections . 10 5.4.4 Indicators and messages on CIE 10 5.4.5 Energy supply . 10 5.5 Explosion isolation devices . 10 5.5.1
12、General . 10 5.5.2 Explosion protection valve (active or passive) F b) evaluating the effectiveness of an explosion isolation system; c) evaluating design tools for explosion isolation systems. This European Standard is applicable only to the use of explosion isolation systems that are intended for
13、avoiding explosion propagation between interconnected enclosures, in which an explosion may result as a consequence of ignition of an explosive mixtures e.g., dust-air mixtures, gas-(vapour-)air mixtures, dust-, gas-(vapour-)air mixtures and mists. In general explosion isolation systems are not desi
14、gned to prevent the transmission of fire or burning powder either of which can initiate an explosion in downstream plant items. It is necessary to take this situation into account in risk assessments. This European Standard is only applicable for gas and dust explosions of chemically stable substanc
15、es and mixtures of these (flame propagating at subsonic velocity). This European Standard is not applicable for explosions of materials listed below, or for mixtures containing some of those materials: i) chemically unstable substances that are liable to decompose; ii) explosive substances; iii) pyr
16、otechnic substances. This European Standard does not cover flame arresters. For these devices refer to EN 12874. 2 Normative references The following reference documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated referenc
17、es, the latest edition of the referenced document (including any amendments) applies. EN 12874:2001, Flame arresters Performance requirements, test methods and limits for use EN 13237, Potentially explosive atmospheres Terms and definitions for equipment and protective systems intended for use in po
18、tentially explosive atmospheres EN 13673-1, Determination of the maximum explosion pressure and the maximum rate of pressure rise of gases and vapours Part 1: Determination of the maximum explosion pressure BS EN 15089:2009EN 15089:2009 (E) 6 EN 13673-2, Determination of maximum explosion pressure a
19、nd the maximum rate of pressure rise of gases and vapours Part 2: Determination of the maximum rate of explosion pressure rise EN 14034-1, Determination of explosion characteristics of dust clouds Part 1: Determination of the maximum explosion pressure pmaxof dust clouds EN 14034-2, Determination of
20、 explosion characteristics of dust clouds Part 2: Determination of the maximum rate of explosion pressure rise (dp/dt)maxof dust clouds EN 14373, Explosion suppression systems 3 Terms and definitions For the purposes of this document, the terms and definitions given in EN 13237, EN 14373 and the fol
21、lowing apply. 3.1 indicating equipment IE explosion protection equipment, which monitors the explosion sensors/detectors and the explosion protection devices 3.2 closing time time needed for closing an isolation device 3.3 closing time of the system sum of the activation time of sensor, activation t
22、ime of isolation device and closing time of the isolation device 3.4 design strength of enclosure p (plant strength) 3.4.1 explosion-pressure-resistant property of vessels and equipment designed to withstand the expected explosion pressure without becoming permanently deformed EN 13237:2003, 3.31 3.
23、4.2 explosion-pressure-shock-resistant property of vessels and equipment designed to withstand the expected explosion pressure without rupturing, but allowing permanent deformation EN 13237:2003, 3.32 3.5 explosion abrupt oxidation or decomposition reaction producing an increase in temperature, pres
24、sure, or in both simultaneously EN 13237:2003, 3.28 3.6 explosion diverter mechanical device, which will divert the explosion to a safe area NOTE It prevents flame jet ignition and pressure piling but cannot effectively stop explosions from travelling. BS EN 15089:2009EN 15089:2009 (E) 7 3.7 explosi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN150892009EXPLOSIONISOLATIONSYSTEMS 爆炸 阻绝 系统 PDF

链接地址:http://www.mydoc123.com/p-572938.html