BS EN 1366-6-2004 Fire resistance tests for service installations - Raised access and hollow core floors《辅助设施的防火试验 架高通道和空心地板》.pdf
《BS EN 1366-6-2004 Fire resistance tests for service installations - Raised access and hollow core floors《辅助设施的防火试验 架高通道和空心地板》.pdf》由会员分享,可在线阅读,更多相关《BS EN 1366-6-2004 Fire resistance tests for service installations - Raised access and hollow core floors《辅助设施的防火试验 架高通道和空心地板》.pdf(20页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS EN 1366-6:2004 Fire resistance tests for service installations Part 6: Raised access and hollow core floors The European Standard EN 1366-6:2004 has the status of a British Standard ICS 13.220.50 BS EN 1366-6:2004 This British Standard was published under the authority of the Sta
2、ndards Policy and Strategy Committee on 18 November 2004 BSI 18 November 2004 ISBN 0 580 44799 5 National foreword This British Standard is the official English language version of EN 1366-6:2004. The UK participation in its preparation was entrusted by Technical Committee FSH/22, Fire resistance te
3、sts, to Subcommittee FSH/22/13, Raised floors, which has the responsibility to: A list of organizations represented on this subcommittee can be obtained on request to its secretary. Cross-references The British Standards which implement international or European publications referred to in this docu
4、ment may be found in the BSI Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Search” facility of the BSI Electronic Catalogue or of British Standards Online. This publication does not purport to include all the necessary provisions of a contract.
5、 Users are responsible for its correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. aid enquirers to understand the text; present to the responsible international/European committee any enquiries on the interpretation, or proposals for ch
6、ange, and keep the UK interests informed; monitor related international and European developments and promulgate them in the UK. Summary of pages This document comprises a front cover, an inside front cover, the EN title page, pages 2 to 16, an inside back cover and a back cover. The BSI copyright n
7、otice displayed in this document indicates when the document was last issued. Amendments issued since publication Amd. No. Date CommentsEUROPEANSTANDARD NORMEEUROPENNE EUROPISCHENORM EN13666 November2004 ICS13.220.50 Englishversion FireresistancetestsforserviceinstallationsPart6:Raised accessandholl
8、owcorefloors ScuritcontrelincendieEssaisdersistanceaufeudes installationsdeservicePartie6:Plancherssurlevset plancherscreux FeuerwiderstandsprfungenfrInstallationenTeil6: DoppelundHohlbden ThisEuropeanStandardwasapprovedbyCENon9July2004. CENmembersareboundtocomplywiththeCEN/CENELECInternalRegulation
9、swhichstipulatetheconditionsforgivingthisEurope an Standardthestatusofanationalstandardwithoutanyalteration.Uptodatelistsandbibliographicalreferencesconcernings uchnational standardsmaybeobtainedonapplicationtotheCentralSecretariatortoanyCENmember. ThisEuropeanStandardexistsinthreeofficialversions(E
10、nglish,French,German).Aversioninanyotherlanguagemadebytra nslation undertheresponsibilityofaCENmemberintoitsownlanguageandnotifiedtotheCentralSecretariathasthesamestatusast heofficial versions. CENmembersarethenationalstandardsbodiesofAustria,Belgium,Cyprus,CzechRepublic,Denmark,Estonia,Finland,Fran
11、ce, Germany,Greece,Hungary,Iceland,Ireland,Italy,Latvia,Lithuania,Luxembourg,Malta,Netherlands,Norway,Poland,Portugal, Slovakia, Slovenia,Spain,Sweden,SwitzerlandandUnitedKingdom. EUROPEANCOMMITTEEFORSTANDARDIZATION COMITEUROPENDENORMALISATION EUROPISCHESKOMITEEFRNORMUNG ManagementCentre:ruedeStassa
12、rt,36B1050Brussels 2004CEN Allrightsofexploitationinanyformandbyanymeansreserved worldwideforCENnationalMembers. Ref.No.EN13666:2004:EEN 1366-6:2004 (E) 2 Contents page Foreword4 Introduction .5 1 Scope.6 2 Normative references6 3 Terms and definitions6 4 Test equipment.7 5 Test conditions.7 5.1 Fur
13、nace temperature.7 5.2 Furnace pressure.7 5.3 Loading conditions8 6 Test specimen8 6.1 Size8 6.2 Number8 6.3 Design.9 6.4 Construction.10 6.5 Verification10 7 Installation of the test specimen 10 8 Conditioning.10 9 Application of instrumentation.10 9.1 Thermocouples10 9.2 Pressure11 9.3 Deflection1
14、1 10 Test procedure.11 10.1 General11 10.2 Application and control of load 11 10.3 Furnace control11 10.4 Observations during the test 11 10.5 Termination of test.11 11 Performance criteria12 11.1 Loadbearing capacity12 11.2 Other criteria.12 12 Test report12 13 Direct application of the test result
15、s12 13.1 General12 13.2 Size of raised or hollow floor12 13.3 Boundary/restraint conditions12 13.4 Panels12 13.5 Pedestals13 13.6 Fixing of pedestals to sub-floor (raised floors only)13 13.7 Fittings13 13.8 Cut panels (raised floors only) .13 13.9 Plenum13 EN 1366-6:2004 (E) 3 13.10 Loading.13 13.11
16、 Temperature/time curve13 Annex A (informative) Guidance on the provision of support for raised or hollow floors inside the furnace 14 A.1 Introduction14 A.2 Method of support using pillars .14 A.3 Method of support fire protected steel beams15 EN 1366-6:2004 (E) 4 Foreword This document (EN 1366-6:
17、2004) has been prepared by Technical Committee CEN/TC 127 “Fire safety in buildings”, the secretariat of which is held by BSI. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by May 2005, and conflic
18、ting national standards shall be withdrawn at the latest by May 2005. This European Standard has been prepared under a Mandate given to CEN by the European and the European Free Trade Association, and supports essential requirements of the Construction Products Directive. EN 1366 Fire resistance tes
19、ts for service installations consists of the following: Part 1: Ducts, Part 2: Fire dampers, Part 3: Penetration seals, Part 4: Linear joint seals, Part 5: Service ducts and shafts, Part 6: Raised access and hollow core floors, Part 7: Conveyor systems and their closures, Part 8: Smoke extraction du
20、cts , Part 9: Single compartment smoke extraction ducts , Part 10: Smoke control dampers, Part 11: Fire protective systems for essential services . According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European
21、Standard: Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EN 1366-6:2004 (E)
22、 5 Introduction In this standard a representative sample of a raised or hollow floor is exposed to a specified regime of heating and loading. The performance of the test specimen is monitored on the basis of criteria described in EN 1363-1. The fire resistance of the tested construction is expressed
23、 as the time for which the appropriate criteria have been satisfied. Caution The attention of all persons concerned with managing and carrying out this fire resistance test, EN 1366-6, is drawn to the fact that fire testing can be hazardous and that there is a possibility that toxic and/or harmful s
24、moke and gases can be evolved during the test. Mechanical and operation hazards can also arise during the construction of the test elements or structures, their testing and disposal of test residues. An assessment of all potential hazards and risks to health should be made and safety precautions sho
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN136662004FIRERESISTANCETESTSFORSERVICEINSTALLATIONSRAISEDACCESSANDHOLLOWCOREFLOORS 辅助 设施 防火 试验 通道

链接地址:http://www.mydoc123.com/p-548924.html