BS 8499-2009 Specification for domestic gas meter boxes and meter bracket《家用煤气表箱和仪表架规范》.pdf
《BS 8499-2009 Specification for domestic gas meter boxes and meter bracket《家用煤气表箱和仪表架规范》.pdf》由会员分享,可在线阅读,更多相关《BS 8499-2009 Specification for domestic gas meter boxes and meter bracket《家用煤气表箱和仪表架规范》.pdf(62页珍藏版)》请在麦多课文档分享上搜索。
1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI British StandardsWB9423_BSI_StandardColCov_noK_AW:BSI FRONT COVERS 5/9/08 12:55 Page 1Specification for domestic gas meter boxes and meter bracketBS 8499:2009BS 8499:2009 BRITISH STANDARDPublishing a
2、nd copyright informationThe BSI copyright notice displayed in this document indicates when the document was last issued. BSI 2009 ISBN 978 0 580 58184 7ICS 91.140.40The following BSI references relate to the work on this standard: Committee reference GSE/25 Draft for comment 09/30160438 DCPublicatio
3、n historyFirst published July 2009Amendments issued since publicationDate Text affected BRITISH STANDARD BSI 2009 iBS 8499:2009ContentsForeword iiiIntroduction 11 Scope 12 Normative references 13 Terms and definitions 34 Dimensions and features 55 Meter bracket (supplied separately) 156 Spigot 157 M
4、aterials 168 Finish 169 Marking 1710 Notices and labels 1711 Type testing and performance requirements 22AnnexesAnnex A (normative) Meter box key 25Annex B (normative) Meter bracket 26Annex C (normative) Polyester moulding compound production testing 33Annex D (normative) Selection of meter box samp
5、les and test plaques for testing 34Annex E (informative) General instructions labels 35Annex F (normative) Methods of test for hinge strength 40Annex G (normative) Method of test for door flatness (built-in and surface mounted boxes) 42Annex H (normative) Cutting plans for meter box test samples 43B
6、ibliography 53List of figuresFigure 1 Typical meter box adaptor with ECV and cap 7Figure 2 Built-in box dimensions and features 8Figure 3 Surface mounted box dimensions and features 10Figure 4 Recommended dimensions and features for new semi-concealed box designs 12Figure 5 Universal box dimensions
7、and features 14Figure 6 Spigot dimensions 15Figure 7 Typical emergency notice 19Figure 8 Typical combined emergency notice 19Figure 9 Spigot knockout warning label (built-in boxes) 20Figure 10 Medium pressure service warning label 21Figure 11 Typical manufacturers label 22Figure A.1 Meter box key 25
8、Figure B.1 Meter bracket dimensions 28Figure B.2 Meter bracket shear bolt dimensions 29Figure B.3 Meter bracket security washer dimensions 30Figure B.4 Location points for measurement of thickness of zinc coatings on meter brackets 31Figure D.1 Basic cutting plan 34Figure E.1 Built-in box general in
9、structions (typical) 36Figure E.2 Surface mounted box general instructions (typical) 37Figure E.3 Semi-concealed box general instructions (typical) 38Figure E.4 Universal box general instructions (typical) 39Figure F.1 Built-in and surface mounted hinge strength test 40Figure F.2 Typical apparatus f
10、or semi-concealed and universal box hinge strength test 41BS 8499:2009ii BSI 2009BRITISH STANDARDFigure H.1 Locations of built-in box body cutting plan 43Figure H.2 Location of built-in box door cutting plan 46Figure H.3 Location of surface mounted box cover cutting plan 47Figure H.4 Location of sur
11、face mounted box back panel cutting plan 48Figure H.5 Location of surface mounted box door cutting plan 49Figure H.6 Location of semi-concealed box body cutting plan 50Figure H.7 Location of semi-concealed box lid cutting plan 51Figure H.8 Location of semi-concealed box extension cutting plan 52List
12、 of tablesTable 1 Flexural properties of box samples 22Table 2 Charpy impact strength of box samples 23Table 3 Hinge strength 23Table C.1 Flexural properties of test plaques 33Table C.2 Charpy impact strength of test plaques 33Summary of pagesThis document comprises a front cover, an inside front co
13、ver, pages i to iv, pages 1 to 54, an inside back cover and a back cover.BRITISH STANDARD BSI 2009 iiiBS 8499:2009ForewordPublishing informationThis British Standard is published by BSI and came into effect on 31 July 2009. It was prepared by Technical Committee GSE/25, Gas meters. A list of organiz
14、ations represented on this committee can be obtained on request to its secretary.Use of this documentIt has been assumed in the preparation of this British Standard that the execution of its provisions will be entrusted to appropriately qualified and experienced people, for whose use it has been pro
15、duced.Presentational conventionsThe provisions of this standard are presented in roman (i.e. upright) type. Its requirements are expressed in sentences in which the principal auxiliary verb is “shall”.Commentary, explanation and general informative material is presented in smaller italic type, and d
16、oes not constitute a normative element.Contractual and legal considerationsThis publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunity from legal obligations.In pa
17、rticular, attention is drawn to the Gas Safety (Installation and Use) Regulations 1998 1.BS 8499:2009iv BSI 2009BRITISH STANDARDThis page deliberately left blankBRITISH STANDARD BSI 2009 1BS 8499:2009IntroductionAs competition in the gas industry has increased, the introduction of new products has l
18、ed to changes to certain designs of meter box for housing gas meters. Consequently, for some types of meter installations the market now comprises several distinct box designs. The number of different designs is causing difficulties for gas installers, meter asset managers and other parties involved
19、 in meter installation.This Standard aims to address some of the disparities in existing box designs to facilitate the installation of meters across the UK. However, it is recognized that some designs, particularly those for the semi-concealed box, will need to be modified over time to obtain a solu
20、tion that meets the aspiration of this Standard.Attention is drawn to the fact that the type and construction of a meter box is subject to approval by the Gas Transporter, and, without this approval, the Gas Transporter may refuse to connect or, in some cases, may disconnect the gas supply to the co
21、nsumers premises.1 ScopeThis British Standard specifies requirements for gas meter boxes for use with single gas meter installations conforming to BS 6400, which:a) are supplied with gases of the 2nd and 3rd family, with a maximum capacity of 6 m3/h and a maximum operating pressure not exceeding 2 b
22、ar; and b) incorporate any of the following meters: diaphragm, ultrasonic, credit or prepayment.It does not apply to multiple meter installations which are installed in the same housing.NOTE 1 The composition of fuel gases of the 2nd and 3rd family is specified in BS EN 437.NOTE 2 All pressures quot
23、ed in this standard are gauge pressures.It covers the following designs of meter box, including any associated box extensions: 1) built-in;2) surface mounted; 3) semi-concealed;4) universal. It does not cover security shrouds intended to provide additional protection to meter installations.This Brit
24、ish Standard also specifies requirements for the design of the standard meter bracket.2 Normative referencesThe following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS84992009SPECIFICATIONFORDOMESTICGASMETERBOXESANDMETERBRACKET 家用 煤气表 仪表 规范 PDF

链接地址:http://www.mydoc123.com/p-547434.html