BS 8103-1-2011 Structural design of low-rise buildings Code of practice for stability site investigation foundations precast concrete floors and ground floor slabs for housing《矮层建筑.pdf
《BS 8103-1-2011 Structural design of low-rise buildings Code of practice for stability site investigation foundations precast concrete floors and ground floor slabs for housing《矮层建筑.pdf》由会员分享,可在线阅读,更多相关《BS 8103-1-2011 Structural design of low-rise buildings Code of practice for stability site investigation foundations precast concrete floors and ground floor slabs for housing《矮层建筑.pdf(66页珍藏版)》请在麦多课文档分享上搜索。
1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationBS 8103-1:2011Structural design of low-risebuildingsPart 1: Code of practice for stability,site investigation, foundations,precast concrete floors and groundfloor slabs for housi
2、ngPublishing and copyright informationThe BSI copyright notice displayed in this document indicates when the documentwas last issued. BSI 2011ISBN 978 0 580 70065 1ICS 91.040.30; 93.020The following BSI references relate to the work on this standard:Committee reference B/204Draft for comment 11/3021
3、4388 DCPublication historyFirst published March 1986Second edition September 1995Third (present) edition November 2011Amendments issued since publicationDate Text affectedBS 8103-1:2011 BRITISH STANDARDContentsForeword iii1 Scope 12 Normative references 13 Terms and definitions and symbols 24 Stabil
4、ity and connections between elements 45 Site investigation 246 Foundations 257 Ground floor slabs 348 Suspended precast concrete floors 37AnnexesAnnex A (informative) Tabular method for the design of suspended cast in situconcrete ground floors 41Bibliography 57List of figuresFigure 1 Diagram illust
5、rating the action of wind forces 5Figure 2 Box construction plan form to give stability 5Figure3Walls with a difference in level on opposite sides 7Figure 4 Building shape 8Figure 5 Maximum height of building on sloping ground 8Figure 6 Measurement of storey height of walls in metres 9Figure 7 Basic
6、 wind speed, V, map (m/s) before the altitude correction isapplied 11Figure 8 Orographic zones for factor O 12Figure 9 Orography factor O for hills and ridges 13Figure 10 Orography factor O for cliffs and escarpments 13Figure 11 Diagram of a house showing location and type of connectionsnecessary be
7、tween elements 15Figure 12 Timber floor bearing on to wall 17Figure 13 Timber floor spanning parallel with a wall 18Figure 14 Timber floor supported on standard joist hanger 19Figure 15 Concrete suspended floor bearing on to wall 20Figure 16 Concrete suspended floor abutting wall 20Figure 17 Precast
8、 concrete beam and block type floor abutting or spanning onto wall 21Figure 18 Tying of pitched roofs to gable walls 22Figure 19 Pitched or flat roof bearing on to a wallplate 23Figure 20 Types of foundation 26Figure 21 Foundation adjoining a trench 32Figure 22 Thickness of foundations 32Figure 23 S
9、tepped foundations 33Figure 24 Position of walls on foundations 34Figure 25 Foundations to walls with projections 34Figure 26 In situ concrete ground-supported slab 35Figure 27 Generic types of precast floor systems 38Figure 28 Typical bearing details for precast floors 40Figure A.1 Definitions 42Fi
10、gure A.2 Tables selection procedure 45Figure A.3 L and T shaped slabs 45List of tablesBRITISH STANDARD BS 8103-1:2011 BSI 2011 iTable 1 Altitude factor 10Table 2 Factor O 10Table 3 Maximum allowable building height, m 14Table 4 Concretes suitable for unreinforced concrete in strip and trench fillfou
11、ndations subject to aggressive chemical conditions in the ground orgroundwater 27Table5Wallload categories for 4.5 m floors and 9 m roofs 28Table6Wallload categories for 6 m floors and 12 m roofs 29Table7Wallload categories for internal wall foundations 30Table 8 Identification of ground material an
12、d minimum foundation widths forwall load categories 31Table 9 Concretes suitable for ground floor slabs 36Table 10 Exposure class for intended use 38Table A.1 Weights of partitions non-loadbearing partitions 43Table A.2 Weights of floor finishes 44Table A.3 Design table for suspended in situ concret
13、e floors No perpendicularpartition load; aspect ratio not greater than 1.8 47Table A.4 Design table for suspended in situ concrete floors Perpendicularpartition load = 0.75 kN/linear m; aspect ratio not greater than 1.8 48Table A.5 Design table for suspended in situ concrete floors Perpendicularpart
14、ition load = 2.0 kN/linear m; aspect ratio not greater than 1.8 49Table A.6 Design table for suspended in situ concrete floors Perpendicularpartition load = 3.75 kN/linear m; aspect ratio not greater than 1.8 50Table A.7 Design table for suspended in situ concrete floors Perpendicularpartition load
15、= 7.0 kN/linear m; aspect ratio not greater than 1.8 51Table A.8 Design table for suspended in situ concrete floors No perpendicularpartition load; aspect ratio greater than 1.8 52Table A.9 Design table for suspended in situ concrete floors Perpendicularpartition load = 0.75 kN/linear m; aspect rati
16、o greater than 1.8 53Table A.10 Design table for suspended in situ concrete floors Perpendicularpartition load = 2.0 kN/linear m; aspect ratio greater than 1. 8 54Table A.11 Design table for suspended in situ concrete floors Perpendicularpartition load = 3.75 kN/linear m; aspect ratio greater than 1
17、.8 55Table A.12 Design table for suspended in situ concrete floors Perpendicularpartition load = 7.0 kN/linear m; aspect ratio greater than 1. 8 56Table A.13 Design table for suspended in situ concrete garage floors 56Summary of pagesThis document comprises a front cover, an inside front cover, page
18、s i to iv,pages 1 to 58, an inside back cover and a back cover.BRITISH STANDARDBS 8103-1:2011ii BSI 2011ForewordPublishing informationThis part of BS 8103 is published by BSI and came into effect on30 November 2011. It was prepared by Technical Committee B/204, Structuraldesign of low-rise buildings
19、. A list of organizations represented on thiscommittee can be obtained on request to its secretary.SupersessionThis part of BS 8103 supersedes BS 8103-1:1995 and BS 8103-4:1995, which arewithdrawn.Relationship with other publicationsBS 8103 will be published in three parts: Part 1: Code of practice
20、for stability, site investigation, foundations andground floor slabs for housing; Part 2: Code of practice for masonry walls for housing; Part 3: Code of practice for timber floors and roofs for housing.Information about this documentThe scope and limitations of this part of BS 8103 are similar to A
21、1/2 Section 2 ofApproved Document A to The Building Regulations 1. A particular exception isthat the maximum clear span for roofs is up to 12 m rather than9minApproved Document A.A large proportion of the national building programmes is concerned with newhousing and alterations in both the public an
22、d private sectors, where traditionalmethods of construction are used for the majority of houses, and it is to thesethat this part of BS 8103 is applicable.Use of this documentIt is assumed that this standard will be used by those with expertise in buildingconstruction but not necessarily in structur
23、al engineering design. Housesconstructed within the limitations stated in the relevant clauses will not requireadditional specialist advice. For any conditions outside the limitations of thisstandard appropriate specialist advice has to be obtained.When using this standard, it is important to ensure
24、 that the overall stability ofthe house is achieved and that the work of any specialist engaged is properlycoordinated. The situations included in this standard which require theconsultation of suitably qualified persons are identified in the clauses to whichthey relate.All drawings in this document
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS810312011STRUCTURALDESIGNOFLOWRISEBUILDINGSCODEOFPRACTICEFORSTABILITYSITEINVESTIGATIONFOUNDATIONSPRECASTCONCRETEFLOORSANDGROUNDFLOORSLABSFORHOUSING

链接地址:http://www.mydoc123.com/p-547265.html