BS 7643-1-1993 Building construction - Expression of users requirements - Thermal requirements《建筑物建造 第1部分 用户要求的表达 供热要求》.pdf
《BS 7643-1-1993 Building construction - Expression of users requirements - Thermal requirements《建筑物建造 第1部分 用户要求的表达 供热要求》.pdf》由会员分享,可在线阅读,更多相关《BS 7643-1-1993 Building construction - Expression of users requirements - Thermal requirements《建筑物建造 第1部分 用户要求的表达 供热要求》.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS 7643-1: 1993 ISO 6242-1: 1992 Building construction Expression of users requirements Part 1: Thermal requirements UDC 69.004.2-533:697:644.1BS7643-1:1993 This British Standard, having been prepared under the directionof the Technical Sector Board for Building and Civil Engineerin
2、g, was published underthe authority ofthe Standards Board and comes into effect on 15March1993 BSI 08-1999 The following BSI references relate to the work on this standard: Committee reference B/500 Draft for comment 89/16526 DC ISBN 0 580 21641 1 Committees responsible for this British Standard The
3、 preparation of this British Standard was entrusted by the Technical Sector Board for Building and Civil Engineering (B/-) to Technical CommitteeB/500, upon which the following bodies were represented: Building Employers Confederation Consumer Policy Committee of BSI Convention of Scottish Local Aut
4、horities Department of Education and Science Department of the Environment Department of the Environment (Building Research Establishment) Incorporated Association of Architects and Surveyors Meteorological Office National Building Specification Ltd. National Council of Building Material Producers N
5、ational House-Building Council Royal Institute of British Architects Society of Chief Architects of Local Authorities Amendments issued since publication Amd. No. Date CommentsBS7643-1:1993 BSI 08-1999 i Contents Page Committees responsible Inside front cover National foreword ii Introduction 1 1 Sc
6、ope 1 2 Users objectives 1 3 Parameters for expressing users requirements 1 4 Factors affecting the choice of criteria 2 Annex A (informative) Bibliography Inside back cover Table 1 Parameters 3 Table 2 Factors affecting criteria 4BS7643-1:1993 ii BSI 08-1999 National foreword This Part of BS7643 ha
7、s been prepared under the direction of Technical CommitteeB/500, Basic data, and is identical with ISO6242-1:1992 Building construction Expression of users requirements Part 1: Thermal requirements, published by the International Organization for Standardization (ISO). ISO 6242-1 was prepared by Sub
8、committee3, Functional/user requirements and performance in building construction, with the active participation and approval of the United Kingdom. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct
9、 application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pages i and ii, pages1 to 4, an inside back cover and a back cover. This standard has been updated (see copyright
10、 date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover.BS7643-1:1993 BSI 08-1999 1 Introduction This part of ISO6242 is one of a set dealing with the expression of environmental requirements for buildings, in terms suitable for use in
11、 regulations and briefs for building projects. The parameters defined can be used for routine verification of the performance of buildings, either by calculation (for example at the design stage) or measurement (for example of spaces or whole buildings), and are meant to provide readily understood i
12、nformation on users requirements throughout the building process. This set of International Standards is not intended to represent the complete state of knowledge about these aspects of environmental science, some of which are the concern of other ISO Technical Committees. 1 Scope This part of ISO 6
13、242 defines how the thermal requirements of building users can be identified, expressed and quantified. It describes users objectives and the parameters used to express them. For each parameter, it specifies units of measurement, preferred increments for values and means of evaluation. It also lists
14、 the environmental and human factors affecting the choice of a value (criterion) for each parameter. It is intended for use a) in preparing briefs for building projects; b) in formulating building laws and regulations; c) in drafting standards and other normative documents; and d) more generally whe
15、n specifying the required performance of buildings in terms of users requirements. Some of the parameters given in this part of ISO6242 apply only to certain types of building. Compliance with this part of ISO6242 does not therefore depend on implementing the whole of its contents in every case. 2 U
16、sers objectives 2.1 Control of the thermal environment within buildings shall fulfil the following objectives: a) to provide conditions which will prevent occupants suffering from heat stress or cold stress; and b) to provide a suitable standard of thermal comfort for occupants. 2.2 Criteria meeting
17、 these objectives shall reflect the following: a) activities to be accommodated; b) clothing; c) age and health of the occupants; d) proportion of likely occupants it is intended to satisfy; e) time during which the requirements must be satisfied (taking account of climatic extremes); and f) any fac
18、ility for local control of the thermal environment by the occupants. The choice of parameters and criteria will differ, depending on the type of climate in which the building is placed. 3 Parameters for expressing users requirements Thermal comfort and freedom from thermal stress depend on the follo
19、wing environmental factors: a) air temperature; b) radiation gains and losses; c) air humidity; d) air velocity; e) metabolic rate; and f) clothing. Requirements can be defined separately for each of these factors, although, because their physiological effects are interdependent, it may be necessary
20、 to give several, cross-related requirements for different ranges of bands of values. It is often convenient to integrate several of the factors into a combined index, such as resultant temperature or operative temperature. In view of the inevitable variation in the thermal environment over space an
21、d time, it is vital that statements of users requirements should not only include limiting values but should also define locations and tolerances for the values: as this kind of information is common to several of the parameters, its expression is given first in3.1. 3.1 Location, uniformity and tole
22、rance for thermal parameters For most spaces within buildings, specified temperatures should apply on a plane1m above finished floor level. On this plane, under continuous operating conditions, the required values (set separately for winter and summer, where applicable) should be met to within a tol
23、erance of 1,5 C, excluding the effects of solar radiation through windows or roof-lights. In certain cases, for example auditoria, it may be necessary to define other planes covering all or part of the space.BS7643-1:1993 2 BSI 08-1999 The maximum temperature gradient in the vertical plane will need
24、 to be specified. For most rooms or spaces of normal height (not exceeding3m) the temperature should not vary by more than3 C. Where heating is intermittent, or where night set-back or other periods of reduced heat input are employed, it may be necessary to specify a) wider tolerance limits within t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS764311993BUILDINGCONSTRUCTIONEXPRESSIONOFUSERSREQUIREMENTSTHERMALREQUIREMENTS 建筑物 建造 部分 用户 要求 表达 供热

链接地址:http://www.mydoc123.com/p-546935.html