BS 7624-2004 Installation and maintenance of domestic direct gas-fired tumble dryers of up to 6 kW heat input (2nd and 3rd family gases) - Specification《热输入值6KW及以下的家用直燃式滚筒干燥机的安装和维修.pdf
《BS 7624-2004 Installation and maintenance of domestic direct gas-fired tumble dryers of up to 6 kW heat input (2nd and 3rd family gases) - Specification《热输入值6KW及以下的家用直燃式滚筒干燥机的安装和维修.pdf》由会员分享,可在线阅读,更多相关《BS 7624-2004 Installation and maintenance of domestic direct gas-fired tumble dryers of up to 6 kW heat input (2nd and 3rd family gases) - Specification《热输入值6KW及以下的家用直燃式滚筒干燥机的安装和维修.pdf(18页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS 7624:2004 Installation and maintenance of domestic direct gas-fired tumble dryers of up to 6 kW heat input (2nd and 3rd family gases) Specification ICS 97.060 BS 7624:2004 This British Standard was published under the authority of Standards Policy and Strategy Committee on 17 Aug
2、ust 2004 BSI 17 August 2004 First published March 1993 Second edition 17 August 2004 The following BSI references relate to the work on this British Standard: Committee reference GSE/30 Draft for Development 01/707909 DC ISBN 0 580 44184 9 Committees responsible for this British Standard The prepara
3、tion of this British Standard was entrusted to Technical Committee GSE/30, Gas installations (1st, 2nd and 3rd family gases), upon which the following bodies were represented: Boiler and Radiator Manufacturers Association Ltd British Flue and Chimney Manufacturers Association BSI Consumer Policy Com
4、mittee Catering Equipment Suppliers Association Centrica plc Council for Registered Gas Installers Department of Trade and Industry Health and Safety Executive Heating and Ventilating Contractors Association ICOM Energy Association Institute of Domestic Heating and Environmental Engineers Institutio
5、n of Gas Engineers and Managers LP Gas Association National Association of the Laundrette Industry Society of British Gas Industries Society of Laundry Engineers and Allied Trades Ltd Co-opted members The following body was also represented in the drafting of this standard, through subcommittees and
6、 panels: Kitchen Specialists Association Amendments issued since publication Amd. No. Date CommentsBS 7624:2004 BSI 17 August 2004 i Contents Page Committee responsible Inside front cover Foreword ii 1S c o p e 1 2 Normative References 1 3T e r m s a n d d e f i n i t i o n s 1 4C o m p e t e n c e
7、2 5 Design and planning 2 6 Selection of tumble dryers 3 7 Location of tumble dryers 4 8 Siting and clearance 4 9 Ventilation (air supply) 5 10 Exhaust venting of tumble dryers 5 11 Gas connections 6 12 Restraining devices 7 13 Electrical wiring and connections 7 14 Commissioning 7 15 Information to
8、 be given to the user 8 Bibliography 12 Figure 1 Typical method of stacking a tumble dryer on another appliance using a stacking kit 9 Figure 2 Wall and window vent terminal installations 10 Figure 3 Installation using a typical restraining device 11BS 7624:2004 ii BSI 17 August 2004 Foreword This B
9、ritish Standard has been prepared by Technical Committee GSE/30. It supersedes BS 7624:1993, which is to be withdrawn in November 2004. A period of three months has been allowed for users of the old standard to convert to the new standard. This revision to BS 7624 reflects changes to the relevant le
10、gislation and the publication of BS EN 1458-1:2000, which covers the safety of gas fired tumble dryers and replaces BS 5258-17. The previously accepted use of a tumble dryer in a flueless mode is not recognised in BS EN 1458 and, accordingly, this standard only endorses the venting options detailed
11、in the scope. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. In particular, attention is drawn to the following s
12、tatutory regulations: The Gas Safety (Installation and Use) Regulations 1998 1 The Gas Safety (Installation and Use) (Northern Ireland) Regulations 2004 2 The Gas Appliances (Safety) Regulations 1995 3 The Building Regulations 2000, as amended 4 The Building Standards (Scotland) Regulations 1990, as
13、 amended 5 The Building Regulations (Northern Ireland) 6 The Gas Safety (Application) (Isle of Man) Order 1996 7 Summary of pages This document comprises a front cover, an inside front cover, pages i and ii, pages 1 to 12, an inside back cover and a back cover. The BSI copyright notice displayed in
14、this document indicates when the document was last issued.BS 7624:2004 BSI 17 August 2004 1 1 Scope This British Standard specifies the installation (see Note 1) of direct gas-fired tumble dryers of up to 6 kW net heat input burning 2nd and 3rd family gases for use in permanent domestic dwellings (s
15、ee Notes 2 and 3). It applies to any such tumble dryer used in conjunction with a flexible venting hose fitted to a wall or window vent terminal or, where the net heat input does not exceed 3kW, with a venting hose hung out of a window, so that combustion products and moisture are exhausted directly
16、 to the outside air. NOTE 1 For the purposes of this standard, installation includes design, inspection and commissioning. It is recognized that each of these tasks can be performed by the same person. NOTE 2 As well as normally constructed dwellings, domestic premises include any permanently sited
17、caravans, holiday homes, residential park homes and permanently moored boats. Additional requirements exist for these categories of premises and can be found in IGE/UP/8 8. Neither this standard nor IGE/UP/8 8 applies to gas installations in towed or motorised caravans. NOTE 3 Whilst this standard s
18、pecifies installations in domestic premises, it is recognized that it might also be referred to for similar installations in commercial and industrial premises. In such cases, additional legislation might be applicable. Attention is drawn to the hazards that exist in certain locations, e.g. hairdres
19、sing salons, where the atmosphere or drying load can contain flammable vapours. 2 Normative References The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the re
20、ferenced document (including any amendments) applies. BS 669-1, Flexible hoses, end fittings and sockets for gas burning appliances Part 1: Specification for strip-wound metallic flexible hoses, covers, end fittings and sockets for domestic appliances burning 1st and 2nd family gases. BS 5440-2:2000
21、, Installation and maintenance of flues and ventilation for gas appliances of rated input not exceeding 70 kW (1st, 2nd and 3rd family gases) Part 2: Specification for installation and maintenance of ventilation for gas appliances. BS 5482-1, Domestic butane- and propane-gas burning installations Pa
22、rt 1: Specification for installations at permanent dwellings. BS 6891, Specification for installation of low pressure gas pipework of up to 28 mm (R1) in domestic premises (2nd family gas). BS 7671, Requirements for electrical installations The IEE Wiring Regulations. 3 Terms and definitions For the
23、 purposes of this British Standard, the following terms and definitions apply. 3.1 appliance flexible connector pipe with appropriate connector ends, designed to have a considerable degree of flexibility to facilitate the connection of a gas appliance to an installation pipe and allow the appliance
24、to be moved a short distance without the need for disconnection BS 669-1 3.2 direct gas-fired tumble dryer appliance in which textile material is dried by tumbling in a rotating drum through which heated air and products of combustion are forced or induced by mechanical means NOTE Hereafter referred
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS76242004INSTALLATIONANDMAINTENANCEOFDOMESTICDIRECTGASFIREDTUMBLEDRYERSOFUPTO6KWHEATINPUT2NDAND3RDFAMILYGASESSPECIFICATION

链接地址:http://www.mydoc123.com/p-546929.html