BS 5992-6-1984 Electrical relays - Specification for the basic modules for the dimensions of general purpose all-or-nothing relays《继电器 第6部分 通用 有 或 无 继电器尺寸的基本模数规范》.pdf
《BS 5992-6-1984 Electrical relays - Specification for the basic modules for the dimensions of general purpose all-or-nothing relays《继电器 第6部分 通用 有 或 无 继电器尺寸的基本模数规范》.pdf》由会员分享,可在线阅读,更多相关《BS 5992-6-1984 Electrical relays - Specification for the basic modules for the dimensions of general purpose all-or-nothing relays《继电器 第6部分 通用 有 或 无 继电器尺寸的基本模数规范》.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS5992-6: 1984 Electrical relays Part6: Specification for the basic modules for the dimensions of general purpose all-or-nothing relays UDC621.318.5-544BS5992-6:1984 This BritishStandard, having been prepared under the directionof the General Electrotechnical Engineering Standards C
2、ommittee, waspublished under the authorityof the Board of BSIandcomes into effect on 31 May1984 BSI11-1999 The following BSI references relate to the work on this standard: Committee reference GEL/5 Draft for comment77/22764DC ISBN 0 580 13861 5 Committees responsible for this BritishStandard The pr
3、eparation of this BritishStandard was entrusted by the General Electrotechnical Engineering Standards Committee (GEL/-) to Technical Committee GEL/5 upon which the following bodies were represented: BEAMA Transmission and Distribution Association British Telecommunications Electricity Supply Industr
4、y in England and Wales Electronics Components Industry Federation Institution of Electrical Engineers Ministry of Defence Telecommunication Engineering and Manufacturing Association (TEMA) The following bodies were also represented in the drafting of the standards through subcommittees and panels: A
5、ssociation of Control Manufacturers TACMA (BEAMA) Association of Manufacturers Allied to the Electrical and Electronic Industry (BEAMA) Electronic Engineering Association Greater London Council National Supervising Inspectorate Society of British Aerospace Companies Limited Amendments issued since p
6、ublication Amd. No. Date of issue CommentsBS5992-6:1984 BSI 11-1999 i Contents Page Committees responsible Inside front cover Foreword ii 1 Scope 1 2 Definitions 1 3 Location of terminal and fixing centres 2 4 Socket-mounted relays 4 5 Relays for printed circuit boards 5 6 Other relays 7 Figure 1 De
7、signation of external dimensions, fixing devices and terminals for relays 2 Figure 2 Example of location for the centres of terminals on one plane of the standard grid 3 Figure 3 Example of location for the terminal and fixing centres on two planes of the standard grid 3 Figure 4 Example of socket-m
8、ounted relay 4 Figure 5 Example of relay for printed circuit board 6 Figure 6 Example of possible location for the fixing centres on the standard grid 7 Table 1 Multipliers for socket-mounted relays 5 Table 2 Multipliers for relays for printed circuit boards 6 Table 3 Multipliers for other relays 8
9、Publications referred to Inside back coverBS5992-6:1984 ii BSI 11-1999 Foreword This Part of this BritishStandard, which has been prepared under the direction of the General Electrotechnical Engineering Standards Committee, is technically equivalent to IEC Publication255-18 “Electrical relays, Part1
10、8: Dimensions for general purpose all-or-nothing relays”, published in1982 by the International Electrotechnical Commission (IEC). Most of the text is identical to the international document. Where changes have been made this has been done to clarify the meaning of the text and to render the scope o
11、f the document more precise. Those Parts of IEC Publication255 “Electrical relays” which are concerned primarily with protection relays are incorporated where required into BS142“Electrical protection relays”. Other Parts of IEC Publication255 which are implemented as BritishStandards form, or will
12、form, Parts of this BritishStandard 1) . Some Parts of IEC Publication255 are designated first level documents, i.e.theycover the requirements of all relays within the scope of IEC Technical Committee No.41, Electrical relays. Other Parts of IEC Publication255 are designated lower level documents, i
13、.e.they are concerned with the requirements of a family of relays (second level) and of smaller and more specialized groups of relays within such a family (third and fourth level). According to this system of classification this is a third level document. A British Standard does not purport to inclu
14、de all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pagesi
15、 andii, pages1 to8, an inside back cover and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover. 1) Parts of IEC255 that form part of the IEC Q Quality Assurance System wi
16、ll also carry a QC series number beginning with the digits16. The corresponding BritishStandards will then become Parts of BS9916.BS5992-6:1984 BSI 11-1999 1 1 Scope This Part of BS5992 specifies the basic dimensional modules to be used in determining the external dimensions of general purpose all-o
17、r-nothing relays and the location of their terminal and fixing centres. It applies equally to all such relays regardless of their type of construction (e.g.electromechanical, electronic, reed, etc.)and includes the height of the socket when the relay is socket-mounted. It also defines the external d
18、imensions and gives preferred values for these in terms of multiples of the specified modules. This standard does not apply to relays standardized by the International Organization for Standardization (ISO) (TC20, Aircraft and space vehicles) or to the internal construction of relays or to the size
19、of fixing arrangements and terminals (see flow-chart). The object of this standard is to state the following for the external dimensions and location of terminal and fixing centres for general purpose all-or-nothing relays: a) definitions (clause2); b) basic module and recommended multipliers (claus
20、e3) for: 1) socket-mounted relays (clause4); 2) relays for printed circuit boards (clause5); 3) other relays (clause6). All dimensions given in this standard are in millimetres. External dimensions are given in integer multiples of the basic module whose value is specified for the various types of r
21、elay. NOTEThe titles of the publications referred to in this standard are listed on the inside back cover. 2 Definitions For the purposes of this Part of BS5992 the following definitions apply. 2.1 general purpose relays general purpose relays are all types of electrical relays, independent of appli
22、cation, with fixing devices and terminalsBS5992-6:1984 2 BSI 11-1999 2.2 dimensions the external dimensions of relays together with their fixing devices and terminals are given in terms of the symbols marked in the general diagram of Figure 1 and the particular example of Figure 4 2.3 basic module m
23、odule is a unit of size used as an increment in modular co-ordination (ISO1791) the basic module M is a step in a grid system as shown in Figure 2 and Figure 3 3 Location of terminal and fixing centres The terminal and fixing centres, which may be on one or more planes, shall be located on, or mid-w
24、ay between, the intersections of the standard grid compatible with the particular surface of the relay(see4.2, 5.2.1, 6.1 and Figure 2 and Figure 3). NOTE to Figure 1 toFigure 4. In the figures Figure 1 Designation of external dimensions, fixing devices and terminals for relays a b c are the maximum
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS599261984ELECTRICALRELAYSSPECIFICATIONFORTHEBASICMODULESFORTHEDIMENSIONSOFGENERALPURPOSEALLORNOTHINGRELAYS

链接地址:http://www.mydoc123.com/p-545534.html