《BS 5857-1 3-1980 Methods for measurement of fluid flow in closed conduits using tracers - Measurement of water flow - Constant rate injection method using radioactive tracers《密封管道中.pdf》由会员分享,可在线阅读,更多相关《BS 5857-1 3-1980 Methods for measurement of fluid flow in closed conduits using tracers - Measurement of water flow - Constant rate injection method using radioactive tracers《密封管道中.pdf(18页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS 5857-1.3: 1980 ISO2975-III: 1977 Methods for measurement of Fluid flow in closed conduits, using tracers Part1: Measurement of water flow Section1.3 Constant rate injection method using radioactive tracers ISO title: Measurement of water flow in closed conduits Tracer methods Par
2、tIII: Constant rate injection method using radioactive tracers UDC 532.542:532.574.87:539.16 CONFIRMED JANUARY 2008BS5857-1.3:1980 This BritishStandard, having been prepared under the directionof the Industrial-process Measurement and Control Standards Committee, was published underthe authority of
3、the Executive Board and comesintoeffect on 31March1980 BSI 12-1999 The following BSI references relate to the work on this standard: Committee referencePCL/2 Draft for comment77/28089DC ISBN 0 580 12489 9 Cooperating organizations The Industrial-process Measurement and Control Standards Committee, u
4、nder whose direction this BritishStandard was prepared, consists of representatives from the following Government department and scientific and industrial organizations: British Gas Corporation British Industrial Measuring and Control Apparatus Manufacturers Association British Steel Corporation CBM
5、PE (Council of British Manufacturers of Petroleum Equipment) Control and Automation Manufacturers Association (BEAMA) Department of Industry (Computers Systems and Electronics) Electrical, Electronic, Telecommunications and Plumbing Union Electricity Supply Industry in England and Wales* Electronic
6、Engineering Association Engineering Equipment Users Association* Institute of Measurement and Control Institution of Electrical Engineers Institution of Gas Engineers Oil Companies Materials Association Post Office Engineering Union Scientific Instrument Manufacturers Association Sira Institute The
7、organizations marked with an asterisk in the above list, together with the following, were directly represented on the committee untrusted with the preparation of this BritishStandard: Department of Energy (Gas Standards) United Kingdom Atomic Energy Authority Amendments issued since publication Amd
8、. No. Date of issue CommentsBS5857-1.3:1980 BSI 12-1999 i Contents Page Cooperating organizations Inside front cover National foreword ii 0 Introduction 1 1 Scope and field of application 1 2 Principle 1 3 Required conditions 1 4 Choice of measuring length 2 5 Procedure 3 6 Methods of analysis and c
9、omputation 5 7 Choice of radioactive tracers 7 8 Example of calculation of flow rate 8 9 Estimation of error 11 Figure 1 Determination of the duration of injection 3 Figure 2 Error on the mean count rate for a certain number of samples 13BS5857-1.3:1980 ii BSI 12-1999 National foreword This BritishS
10、tandard has been prepared under the direction of the Industrial-process Measurement and Control Standards Committee and is identical with ISO2975-III:1976 “Measurement of water flow in closed conduits Tracer methods PartIII: Constant rate injection method using radioactive tracers” published by the
11、International Organization for Standardization (ISO). Terminology and conventions. The text of the International Standard has been approved as suitable for publication, without deviation, as a BritishStandard. Some terminology and certain conventions are not identical with those used in BritishStand
12、ards; attention is especially drawn to the following. The comma has been used throughout as a decimal marker. In BritishStandards it is current practice to use a full point on the baseline as the decimal marker. Wherever the words “International Standard” appear, referring to this standard, they sho
13、uld be read as “BritishStandard”. Additional information. In the table in7.2 the SI unit for concentration is the Bq/cm 3where1Bq=3.7 10 10 Ci. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct appl
14、ication. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pagesi andii, pages1 to13 and a back cover. This standard has been updated (see copyright date) and may have had amend
15、ments incorporated. This will be indicated in the amendment table on the inside front cover.BS5857-1.3:1980 BSI 12-1999 1 0 Introduction This International Standard is the third of a series of standards covering tracer methods of water flow measurement in closed conduits. The complete series of stan
16、dards will be as follows: PartI: General; PartII: Constant rate injection method using non-radioactive tracers; PartIII: Constant rate injection method using radioactive tracers; PartIV: Integration (sudden injection) method using non-radioactive tracers; PartV: Integration (sudden injection) method
17、 using radioactive tracers; PartVI: Transit time method using non-radioactive tracers; PartVII: Transit time method using radioactive tracers. 1 Scope and field of application This International Standard specifies the constant rate injection method using radioactive tracers for the measurement of wa
18、ter flow rate in closed conduits. 2 Principle Flow rate measurement by a constant rate injection method is based on a comparison between the concentration C 1of a tracer continuously introduced with a known volume rate of flow q, and the concentration of samples C 2taken at some place beyond the dis
19、tance 1) . The mixing distance is defined as the shortest distance at which the variation in concentration of the tracer over the cross-section is less than some pre-determined value (for example0,5%). (See clause6 of part1.) The tracer rate at the injection point is equal to the rate at which it pa
20、sses the sampling point: q C 1 + Q C 0 =(Q + q) C 2 Where C 0is the initial concentration in the stream which is flowing at the rate Q. Hence: Generally C 1is much greater than C 2which leads to a simplification of equation(1) as follows: When C 2is much greater than C 0 , the equation can be reduce
21、d still further to Flow rate Q can thus be determined by comparing the concentration of the injected solution with the concentration of samples removed from the conduit. 3 Required conditions 3.1 Tracer For the constant rate injection method the tracer shall meet the general requirements defined in5
22、.1 of partI. A list of generally used tracers is given in5.1.2 of partI and their advantages with respect to non-radioactive tracers are stated in5.2.1.1 and5.2.1.2. 3.2 Duration of injection The duration of injection shall be such that stable concentration conditions are established at all points o
23、f the measuring cross-section over a sufficient period of time. Constant concentration shall be obtained for a period of at least several minutes. 1) Another method can be contemplated which would not involve sampling. . . . (1)BS5857-1.3:1980 2 BSI 12-1999 Determination of the injection duration A
24、suitable duration of injection may be determined by a preliminary investigation involving the instantaneous injection of a dye such as fluorescein or a radioactive tracer. Curves1 and2 ofFigure 1 may be plotted for a given flow rate from the observation of the moment when the tracer (dye or activity
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS5857131980METHODSFORMEASUREMENTOFFLUIDFLOWINCLOSEDCONDUITSUSINGTRACERSMEASUREMENTOFWATERFLOWCONSTANTRATEINJECTIONMETHODUSINGRADIOACTIVETRACERS

链接地址:http://www.mydoc123.com/p-545438.html