BS 5126-3-1993 Mining type flameproof supply and control units for use on systems up to 1100 V Specification for air-cooled lighting transformer units《电压可达1100V的系统用矿山型阻燃式电源和控制装置 第3.pdf
《BS 5126-3-1993 Mining type flameproof supply and control units for use on systems up to 1100 V Specification for air-cooled lighting transformer units《电压可达1100V的系统用矿山型阻燃式电源和控制装置 第3.pdf》由会员分享,可在线阅读,更多相关《BS 5126-3-1993 Mining type flameproof supply and control units for use on systems up to 1100 V Specification for air-cooled lighting transformer units《电压可达1100V的系统用矿山型阻燃式电源和控制装置 第3.pdf(24页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS 5126-3: 1993 Mining type flameproof supply and control units for use on systems up to1100V Part 3: Specification for air-cooled lighting transformer unitsBS5126-3:1993 This British Standard, having been prepared under the directionof the Mining RequisitesStandards Policy Committe
2、e, waspublished underthe authorityof the Standards Boardand comes intoeffect on 15December1993 BSI 09-1999 First published May1982 Second edition December1993 The following BSI references relate to the work on this standard: Committee reference MRE/16 Draft for comment91/75762 DC ISBN 0 580 22423 6
3、Committees responsible for this British Standard The preparation of this British Standard was entrusted by the Mining Requisites Standards Policy Committee (MRE/-) to Technical Committee MRE/16, upon which the following bodies were represented: Association of British Mining Equipment Companies Briti
4、sh Coal Corporation Health and Safety Executive Amendments issued since publication Amd. No. Date CommentsBS5126-3:1993 BSI 09-1999 i Contents Page Committees responsible Inside front cover Foreword ii 1 Scope 1 2 References 1 3 Definitions 1 4 Information and requirements to be agreed and to be doc
5、umented 2 5 Service conditions 2 6 Rated values 2 7 Design and construction 3 8 Verification and tests 8 9 Marking 9 Figure 1 Outline of enclosures showing arrangements for earthing terminals and skid couplings 10 Figure 2 Busbar chamber end flange 11 Figure 3 Busbar interconnecting trunk with cover
6、 plate 12 Figure 4 650/1100 V busbar interconnecting adaptor trunk 13 Figure 5 650/1100 V skid coupling plate 14 Figure 6 End cover for busbar chamber 15 Figure 7 Envelope dimensions for padlocks 16 Table 1 Creepage distance and clearance 7 List of references 18BS5126-3:1993 ii BSI 09-1999 Foreword
7、This Part of BS5126has been prepared under the direction of the Mining Requisites Standards Policy Committee. It supersedes BS5126-3:1982, which is withdrawn. This revision updates the standard to reflect todays usage of1100V mining type flameproof supply and control units (commonly known in the UK
8、as“gate-end boxes”) and takes account of expected future development. This Part of BS5126covers units in which the essential apparatus are lighting transformer units, whilst Parts1, 2and4cover motor starters, circuit breaker units and units to power drilling machines, respectively. All have standard
9、 busbar and other fixing dimensions, enabling the different units to be fastened together to form a switchboard. This standard is arranged to be in close alignment with IEC (International Electrotechnical Commission) criteria for various electrical features. A British Standard does not purport to in
10、clude all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Attention is drawn to the Health and Safety at Work etc. Act19741, the Mines and Q
11、uarries Act19542, the Regulations made under these Acts, and also any other appropriate statutory requirements or byelaws. These place responsibility for complying with certain specific safety requirements on the manufacturer and the user. The addresses of the recognized certification authorities in
12、 the United Kingdom for Group I (mines susceptible to firedamp) apparatus are: Health and Safety Executive Mining Equipment Certification Service Harpur Hill, Buxton, Derbyshire, SK17 9JN SIRA Certification Service Saighton Lane Saighton Chester, CH3 6EG Summary of pages This document comprises a fr
13、ont cover, an inside front cover, pagesiand ii, pages1 to 18, an inside back cover and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover.BS5126-3:1993 BSI 09-1999 1 1 Sco
14、pe This Part of BS5126specifies requirements for flameproof supply and control units designed primarily for use in the coal mining industry on1100V three-phase a.c. circuits containing single-phase transformers intended for supplying lighting and other circuits. In addition to the definitive require
15、ments, this standard also requires the items detailed in clause 4 to be documented. For compliance with this standard, both the definitive requirements and the documented items have to be satisfied. NOTE 1To facilitate cross-reference and subject location recall between the Parts of this standard, a
16、 uniformity of clause arrangements is maintained. At subclause level, because of the different purposes and individual technical features of the four types of control unit, some differences in title and/or subclause arrangements have been unavoidable, but have been made without disturbing the genera
17、l pattern. Thus, in this Part, subclauses7.11 and7.14 remain unused. NOTE 2The figures in this standard show only such features and dimensions essential for function and interchangeability. Dimensions are in millimetres. Untoleranced values less than100mm are 0.15mm and those greater than100mm are 0
18、.25mm. 2 References 2.1 Normative references This Part of BS5126incorporates, by reference, provisions from specific editions of other publications. These normative references are cited at the appropriate points in the text and the publications are listed on pages18 and 19. Subsequent amendments to,
19、 or revisions of, any of these publications apply to this Part of BS5126only when incorporated in it by updating or revision. 2.2 Informative references This Part of BS5126refers to other publications that provide information or guidance. Editions of these publications current at the time of issue o
20、f this standard are listed on the pages 18 and 19, but reference should be made to the latest editions. 3 Definitions For the purposes of this Part of BS5126, the following definitions apply. 1) 3.1 supply and control unit (gate-end box) a flameproof enclosure containing electrical apparatus, such a
21、s transformers, control gear, switchgear and/or protective gear, designed primarily for use underground NOTE 1In this Part of BS5126, the term “unit” has in many instances been used in abbreviation of “supply and control unit”. NOTE 2For the purposes of this Part of BS5126, the enclosed apparatus is
22、 essentially a single-phase air-cooled transformer with associated equipment to provide a supply for lighting purposes. 3.2 switch disconnector (isolating switch) a switch which isolates a circuit and is capable of breaking not less than its rated current at rated voltage 3.3 cable half coupler (fli
23、t plug) a detachable cable sealing box utilizing contact tubes and pins to facilitate ready connection to, or disconnection from, a similar unit or other apparatus 3.4 cable coupler adaptor a device used to connect either a cable half coupler or other type of cable termination to apparatus. If used
24、to connect a cable half coupler, it may either be separate from, or be integral with, the enclosure of the apparatus 3.5 cable sealing box a device designed to receive and protect the end of the cable, with provision for sealing the conductors and the insulating material of the cable with a filling
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS512631993MININGTYPEFLAMEPROOFSUPPLYANDCONTROLUNITSFORUSEONSYSTEMSUPTO1100VSPECIFICATIONFORAIRCOOLEDLIGHTINGTRANSFORMERUNITS

链接地址:http://www.mydoc123.com/p-544869.html