《BS 3680-4I-1986 Methods of measurement of liquid flow in open channels Weirs and flumes V-shaped broad crested weirs《明渠流量测量 第4部分 溢流堰和斜槽 第4I节 V形宽顶堰》.pdf》由会员分享,可在线阅读,更多相关《BS 3680-4I-1986 Methods of measurement of liquid flow in open channels Weirs and flumes V-shaped broad crested weirs《明渠流量测量 第4部分 溢流堰和斜槽 第4I节 V形宽顶堰》.pdf(22页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD CONFIRMED MARCH 1998 BS 3680-4I: 1986 ISO 8333:1985 Measurement of liquid flow in open channels Part 4: Weirs and flumes Part 4I: V-shaped broad crested weirs ISO title: Liquid flow measurement in open channels by weirs and flumes V-shaped broad crested weirs UDC 532.543:532.57:681.
2、12BS3680-4I:1986 This British Standard, having been prepared under the directionof the Industrial-process Measurementand Control Standards Committee, was published under the authorityofthe Board of BSIandcomes intoeffect on 30September1986 BSI 12-1999 The following BSI references relate to the work
3、on this standard: Committee reference PCL/3 Draft for comment 84/21095 DC ISBN 0 580 15312 6 Committees responsible for this British Standard The preparation of this British Standard was entrusted by the Industrial-process Measurement and Control Standards Committee (PCL/-) to Technical Committee PC
4、L/3, upon which the following bodies were represented: Department of the Environment for Northern Ireland Department of the Environment Welsh Office Institute of Measurement and Control Institution of Civil Engineers Institution of Water Engineers and Scientists Scottish Development Department Water
5、 Authorities Association The following bodies were also represented in the drafting of the standard, through subcommittees and panels: Anglian Water Authority British Effluent and Water Association Amendments issued since publication Amd. No. Date of issue CommentsBS3680-4I:1986 BSI 12-1999 i Conten
6、ts Page Committees responsible Inside front cover National foreword ii 1 Scope and field of application 1 2 References 1 3 Definitions 1 4 Units of measurement 1 5 Installation 1 6 General requirements for maintenance 4 7 Measurement of head 4 8 V-shaped broad-crested weirs 6 9 Discharge equations 7
7、 10 Errors in flow measurement 9 Annex A Scaling effects 13 Annex B “More than full” flow 14 Annex C Submerged flow 15 Figure 1 V-shaped broad-crested weir 3 Figure 2 Longitudinal section of three types of construction 3 Figure 3 Determination of head-gauge datum 5 Figure 4 Dimensions of weir and fl
8、ow 6 Figure 5 Discharge coefficient as a function of h 1 /L 7 Figure 6 Flow-pattern above crest for free flow with h 1 /L = 0,353 8 Figure 7 Dimensions for “more than full” flow 14 Figure 8 Modular limit for V-shaped broad-crested weirs 15 Figure 9 Submerged flow reduction factor for V-shaped broad-
9、crested weirs 16 Publications referred to Inside back coverBS3680-4I:1986 ii BSI 12-1999 National foreword This Part of BS3680 has been prepared under the direction of the Industrial-process Measurement and Control Standards Committee. It is identical with ISO8333:1985 “Liquid flow measurement in op
10、en channels by weirs and flumes V-shaped broad-crested weirs”, published by the International Organization for Standardization (ISO). Terminology and conventions. The text of the International Standard has been approved as suitable for publication as a British Standard without deviation. Some termin
11、ology and certain conventions are not identical with those used in British Standards; attention is drawn especially to the following. Wherever the words “International Standard” appear, referring to this standard, they should be read as “British Standard”. The comma has been used as a decimal marker
12、. In British Standards it is current practice to use a full point on the baseline as the decimal marker. The Technical Committee has reviewed the provisions of ISO772:1978, to which reference is made in the text, and has decided that they are acceptable for use in conjunction with this standard. A r
13、elated British Standard to ISO772 is BS3680-1:1983 “Glossary of terms”. A related British Standards to ISO4374, which is quoted for information purposes only is BS3680-4F:1981. At present there is no corresponding British Standard for ISO4373:1979 which is quoted for information purposes only. A Bri
14、tish Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Cross-references International Standard Corres
15、ponding British Standard ISO 5168:1978 BS 5844:1981 Methods of measurement of fluid flow: estimation of uncertainty of a flowrate measurement (Identical) Summary of pages This document comprises a front cover, an inside front cover, pages i and ii, pages 1 to 16, an inside back cover and a back cove
16、r. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover.BS3680-4I:1986 BSI 12-1999 1 1 Scope and field of application This International Standard specifies a method for the measurement of
17、 subcritical flow in small rivers and artificial channels using V-shaped broad-crested weirs. The advantages of this type of weir are described inclause8. NOTEA comparison of the different types of weirs and flumes will form the subject of a future International Standard. 2 References ISO 772, Liqui
18、d flow measurement in open channels Vocabulary and symbols. ISO 4373, Measurement of liquid flow in open channels Water level measuring devices. ISO 4374, Liquid flow measurement in open channels Round-nose horizontal crest weirs. ISO 5168, Measurement of fluid flow Estimation of uncertainty of a fl
19、ow-rate measurement. 3 Definitions For the purposes of this International Standard, the definitions given in ISO772 apply. 4 Units of measurement The units of measurement used in this International Standard are SI units. 5 Installation 5.1 Selection of site A preliminary survey shall be made of the
20、physical and hydraulic features of the proposed site to check that it conforms (or may be made to conform) to the requirements necessary for measurement using the weir. Particular attention shall be paid to the following features in selecting the site of the weir: a)the availability of an adequate l
21、ength of channel of regular cross-section; b)the existing velocity distribution; c)the avoidance of channels having gradients greater than1 in250; d)the consequential effects of any increased upstream water level due to the measuring structure; e)the consequential conditions downstream, including su
22、ch influences as tides, confluences with other streams, sluice gates, mill dams and other controlling features which might cause drowning; f)the impermeability of the ground on which the structure is to be founded, and the necessity for piling, grouting or other sealing in river installations; g)the
23、 necessity for flood banks to confine the maximum discharge to the channel; h)the stability of the banks, and the necessity for trimming and/or revetment in natural channels; j)the clearance of rocks or boulders from the bed of the approach channel; k)the effects of wind (wind can have a considerabl
24、e effect on the flow in a river or over a weir, especially if these are wide and the head is small and when the prevailing wind is in a transverse direction). If the site does not possess the characteristics required for satisfactory measurements, it shall be rejected unless suitable improvements ar
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS36804I1986METHODSOFMEASUREMENTOFLIQUIDFLOWINOPENCHANNELSWEIRSANDFLUMESVSHAPEDBROADCRESTEDWEIRS 明渠 流量

链接地址:http://www.mydoc123.com/p-543822.html