BS 3056-4-1985 Sizes of refractory bricks - Specification for bricks for electric arc furnace roofs《耐火砖尺寸 第4部分 电弧炉顶用耐火砖规范》.pdf
《BS 3056-4-1985 Sizes of refractory bricks - Specification for bricks for electric arc furnace roofs《耐火砖尺寸 第4部分 电弧炉顶用耐火砖规范》.pdf》由会员分享,可在线阅读,更多相关《BS 3056-4-1985 Sizes of refractory bricks - Specification for bricks for electric arc furnace roofs《耐火砖尺寸 第4部分 电弧炉顶用耐火砖规范》.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS3056-4: 1985 ISO5019-4: 1984 Sizes of refractory bricks Part4: Specification for bricks for electric arc furnace roofs ISO title: Refractory bricks Dimensions Part4: Dome bricks for electric arc furnace roofs UDC 666.76431:66.042.87.043.1:621.365.2BS3056-4:1985 This British Standa
2、rd, having been prepared under the directionof the Refractory Products Standards Committee, was published under the authorityof the Board of BSI andcomes into effect on 29March1985 BSI08-1999 First published February1959 First revision August1973 First (Part) revision March1985 The following BSI ref
3、erences relate to the work on this standard: Committee reference RPM/4 Draft for comment82/77721 DC ISBN 0 580 14392 9 Committees responsible for this British Standard The preparation of this British Standard was entrusted by the Refractory Products Standards Committee (RPM/-) to Technical Committee
4、 RPM/4, upon which the following bodies were represented: British Ceramic Research Association British Gas Corporation British Metallurgical Plant Constructors Association British Steel Industry Cement Makers Federation Coke Oven Managers Association Glass Manufacturers Federation Institute of Refra
5、ctories Engineers Refractories Association of Great Britain Society of Glass Technology Society of Industrial Furnace Engineers Water-tube Boilermakers Association Amendments issued since publication Amd. No. Date of issue CommentsBS3056-4:1985 BSI 08-1999 i Contents Page Committees responsible Insi
6、de front cover National foreword ii 1 Scope and field of application 1 2 Dimensions 1 3 Brick designation 1 Annex A Commentary on the bricks selected for roof construction 3 Figure 1 Designation of brick dimensions in the Table 1 Figure 2 Relationship between roof diameter, roof rise and spherical r
7、adius 4 Table Dimensions of bricks for electric arc furnace roofs 2BS3056-4:1985 ii BSI 08-1999 National foreword This Part of BS3056 has been prepared under the direction of the Refractory Products Standards Committee. BS3056:1973 is being revised as a series of Parts so that it will cover bricks f
8、or a wide range of specific applications and will be withdrawn on publication of the complete series of revised standards. This Part is identical with ISO5019 “Refractory bricks Dimensions” Part4:1984 “Dome bricks for electric arc furnace roofs”, published by the International Organization for Stand
9、ardization (ISO). The series of brick sizes specified in this Part of BS3056 are annulus-shaped for use in roofs of ringed dome construction, the sizes being derived from a basic114mm 76mm cross section. The bricks are laid in the roof with their114mm dimension set radially and provision is made, by
10、 virtue of varying brick length, to accommodate three different roof thicknesses. Terminology and conventions. The text of the International Standard has been approved as suitable for publication as a British Standard without deviation. Some terminology and certain conventions are not identical with
11、 those used in British Standards; attention is drawn especially to the following. The comma has been used as a decimal marker. In British Standards it is current practice to use a full point on the baseline as decimal marker. Where the words “part of ISO5019” appear, referring to this standard, they
12、 should be read as “Part of BS3056”. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summ
13、ary of pages This document comprises a front cover, an inside front cover, pagesi andii, pages1 to4 and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover.BS3056-4:1985 BS
14、I 08-1999 1 1 Scope and field of application This part of ISO5019 specifies the dimensions of refractory bricks for use in the domes of electric arc furnace roofs. 2 Dimensions The dimensions of refractory bricks for use in the domes of electric arc furnace roofs shall be as shown in the Table. The
15、letter references used in the Table are illustrated in Figure 1. NOTEA commentary on the brick sizes specified is included in the Annex. 3 Brick designations The bricks of the different dimensions shall be designated by the reference numbers shown in the Table. In these reference numbers: a) the fir
16、st letter (H, J or K) indicates the brick length (roof thickness)(230mm;250mm or300mm); b) the second letter (W, X, Y or Z) indicates the spherical radius(2,7m;4,5m;6,3m or8,1m); c) the digit in the third place(1,2,3 or4) indicates the side arch taper(2mm;3mm;6mm or13mm). Figure 1 Designation of bri
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS305641985SIZESOFREFRACTORYBRICKSSPECIFICATIONFORBRICKSFORELECTRICARCFURNACEROOFS 耐火砖 尺寸 部分 电弧炉 顶用 规范

链接地址:http://www.mydoc123.com/p-543538.html