BS 2501-1992 Specification for commercial refrigerated storage cabinets of the closed reach-in type《商业用封闭式冷冻贮舱规范》.pdf
《BS 2501-1992 Specification for commercial refrigerated storage cabinets of the closed reach-in type《商业用封闭式冷冻贮舱规范》.pdf》由会员分享,可在线阅读,更多相关《BS 2501-1992 Specification for commercial refrigerated storage cabinets of the closed reach-in type《商业用封闭式冷冻贮舱规范》.pdf(26页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS 2501:1992 Specification for Commercial refrigerated storage cabinets of the closed reach-in typeBS2501:1992 This British Standard, having been prepared under the directionof the Refrigeration,Heating and AirConditioning Standards PolicyCommittee, was publishedunder the authorityo
2、fthe StandardsBoardand comes intoeffect on 1 April1992 BSI 08-1999 First published August 1954 Second edition April 1976 Third edition April 1992 The following BSI references relate to the work on this standard: Committee reference RHE/19 Draft for comment 90/80825 DC ISBN 0 580 20094 9 Committees r
3、esponsible for this British Standard The preparation of this British Standard was entrusted by the Refrigeration, Heating and Air Conditioning Standards Policy Committee (RHE/-) to Technical Committee RHE/19, upon which the following bodies were represented: British Gas plc British Hotels and Restau
4、rants and Caterers Association British Refrigeration Association British Retailers Association Cooperative Union Department of Health Ice Cream Federation Ltd. Institute of Refrigeration Institution of Electrical Engineers Institution of Environmental Health Officers Institution of Grocery Distribut
5、ion London Refrigeration Society Ministry of Agriculture, Fisheries and Food Retail Consortium United Kingdom Association of Frozen Food Producers The following body was also represented in the drafting of the standard, through subcommittees and panels: Department of the Environment (Property Servic
6、es Agency) Amendments issued since publication Amd. No. Date CommentsBS2501:1992 BSI 08-1999 i Contents Page Committees responsible Inside front cover Foreword ii Section 1. General 1 Scope 1 2 Definitions 1 Section 2. Calculation of internal volumes and shelf spaces 3 Calculation of internal volume
7、s and shelf spaces 3 Section 3. Construction 4 Construction 4 Section 4. Electrical and electronic equipment 5 Electrical and electronic equipment 7 Section 5. Marking and information 6 Marking and information 12 Appendix A Production tests 13 Appendix B Type tests 14 Figure 1 Test fingers 11 Figure
8、 2 Air movement 16 Figure 3 Loading of cabinet 18 Table 1 Minimum exterior surface temperature of the cabinet 6 Table 2 Creepage distances and clearances 10 Table 3 System test pressures 13 Table 4 Climate classes 15 Table 5 Sizes and masses of test packages 17 Publication(s) referred to Inside back
9、 coverBS2501:1992 ii BSI 08-1999 Foreword This revision of BS2501 has been prepared under the direction of the Refrigeration, Heating and Air Conditioning Standards Policy Committee (RHE/-). It supersedes BS2501:1976, which is withdrawn. The standard is complementary to BS2502 which deals with refri
10、gerating equipment of larger capacity. Reference should be made to BS3053 for the requirements for commercial refrigerated cabinets intended for the sale and/or display of food products and to BS4434 for the safe use of refrigerating equipment. During the preparation of this revision the “Montreal P
11、rotocol” was ratified. This will have an effect on the availability and handling of refrigerants in the future. It is intended to review the requirements of the standard as refrigerant technology and alternative refrigerants are developed. A British Standard does not purport to include all the neces
12、sary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pages i and ii, pages1
13、 to 20, an inside back cover and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on theinside front cover.BS2501:1992 BSI 08-1999 1 Section 1. General 1 Scope This British Standard specifies the
14、 construction, the methods of calculating internal volumes and shelf areas, and the method of determining performance of refrigerated storage cabinets of the closed reach-in type, for commercial use in catering and similar applications. The cabinets are intended for use in climates having dry bulb t
15、emperatures and relative humidities from16 C and80% to40 C and40%. The approximate limits of internal temperatures intended to be covered by this standard are between 30 C and+10 C. NOTEThe titles of the publications referred to in this standard are listed on the inside back cover. 2 Definitions For
16、 the purposes of this British Standard, the definitions given in BS5643 apply together with the following. 2.1 test room climate class a test room climate numbered between1and5which is related to dry bulb temperature and relative humidity (seeTable 4) 2.2 cabinets of the closed reach-in type cabinet
17、s having access at the top and/or sides, fitted with lids or doors which are kept closed in normal use, and where the contents in any part of the interior may be reached without stepping into the refrigerated space 2.3 condensing unit the high-pressure components of a refrigerating system, including
18、 a power driven compressor, a condenser and, if required, a liquid receiver 2.4 open-type compressor unit a unit in which the compressor and the motor are separately mounted and mechanically linked through a belt or equivalent drive 2.5 hermetically sealed compressor unit a refrigerant compressor an
19、d motor assembly enclosed in a shell, rendered gas-tight by welding or other suitable means 2.6 semi-hermetically sealed compressor unit a refrigerant compressor and motor assembly enclosed in a shell, rendered gas-tight by bolting 2.7 automatic defrosting the defrosting of a cabinet or part of a ca
20、binet where the frequency and duration of the defrost operation and removal of the defrost water from the refrigerated space do not require any action by the user 2.8 semi-automatic defrosting the defrosting of a cabinet or part of a cabinet when the start of each defrost operation is by action of t
21、he user, the defrost water being removed from the refrigerated space without any action by the user 2.9 manual defrosting the defrosting of a cabinet or part of a cabinet when the start and duration of each defrost operation is by action of the user, the defrost water, frost or ice being removed fro
22、m the refrigerated space with or without any action by the user 2.10 refrigerating system the condensing unit, evaporator(s), valves, piping and other components through which the refrigerant circulates 2.11 refrigerant the medium for conveying heat in a refrigerating system. This medium is evaporat
23、ed by absorbing heat at a lower temperature and liquefied by surrendering heat at a higher temperature 2.12 high-pressure side the portion of a refrigerating system subject to the higher or condenser pressure 2.13 low-pressure side the portion of a refrigerating system subject to the lower or evapor
24、ator pressure 2.14 evaporator (cooling unit) the portion of a refrigerating system in which liquid refrigerant is evaporated by the reception of heat 2.15 refrigerator a cabinet or cabinets, provided with means for being cooled, together with the associated refrigerating system which may be located
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS25011992SPECIFICATIONFORCOMMERCIALREFRIGERATEDSTORAGECABINETSOFTHECLOSEDREACHINTYPE 商业 封闭式 冷冻 规范 PDF

链接地址:http://www.mydoc123.com/p-543156.html