BHMA A156 10-2017 POWER OPERATED PEDESTRIAN DOORS.pdf
《BHMA A156 10-2017 POWER OPERATED PEDESTRIAN DOORS.pdf》由会员分享,可在线阅读,更多相关《BHMA A156 10-2017 POWER OPERATED PEDESTRIAN DOORS.pdf(58页珍藏版)》请在麦多课文档分享上搜索。
1、 1ANSI/BHMA A156.10 -2017 Revision of ANSI/BHMA A156.10-2011 STANDARD FOR POWER OPERATED PEDESTRIAN DOORS SPONSOR BUILDERS HARDWARE MANUFACTURERS ASSOCIATION, INC. AMERICAN NATIONAL STAN DARDS INSTITUTE Approved July 21, 2017 2AMERICAN NATIONAL STANDARD An American National Standard implies a consen
2、sus of those substantially concerned with its scope and provisions. An American National Standard is intended as a guide to aid the manufacturer, the consumer and the general public . The existence of an American National Standard does not in any respect preclude anyone, whether he has approved the
3、standard or not, from manufacturing, marketing, purchasing, or using products, processes, or procedures not conforming to this standard. American National Standards are subject to periodic review and users are cautioned to obtain the latest editions. CAUTION NOTICE: This American National Standard i
4、s permitted to be revised or withdrawn at any time. The procedures of the American Nation al Standards Institute require that action be taken to reaffirm, revise, or withdraw this standard no later than five years from the date of publication. Purchasers of American National Standards receive curren
5、t information on all standards by calling or writing the American National Standards Institute. Published by BUILDERS HARDWARE MANUFACTURERS ASSOCIATION, INC. 355 Lexington Avenue New York, New York 10017 Copyright 2017 by the Builders Hardware Manufacturers Association, Inc. Not to be reproduced w
6、ithout specific authorization from BHMA Printed in the USA This Standard was approved by ANSI under the Canvass Method. BHMA was accredited on 21 March 1983 by ANSI as a sponsor using the Canvass Method. 3FOREWORD (This Foreword is not a part of ANSI/BHMA A156.10) The general classification of build
7、ers hardware includes a wide variety of items which are divided into several categories. To recognize this diversity, a sectional classification system has been established. Power Operated Doors is one such section and this Standard is a result of the collective efforts of members of the Builders Ha
8、rdware Manufacturers Association, Inc. who manufacture this product. The total Product Standards effor t is, therefore, a collection of sections, each covering a specific category of items. Performance tests and, where necessary, dimensional requirements have been established to ensure a degree of s
9、afety. There are no restrictions on design except for those dimensional requirements imposed for reasons of safety. This Standard is not intended to obstruct but rather to encourage the development of improved products, methods and materials. The BHMA recognizes that errors will be found, items will
10、 beco me obsolete, and new products, methods and materials will be developed. With this in mind, the Association plans to update, correct and revise these Standards on a regular basis. It shall also be the responsibility of manufacturers to request such approp riate revisions. 4TABLE OF CONTENTS 1.
11、GENERAL 5 2. DEFINITIONS OF TE RMS USED IN THIS STA NDARD . 6 3. SWINGING DOORS 8 4. SLIDING DOORS 8 5. FOLDING DOORS . 8 6. GUIDE RAILS 9 7. CONTROL MATS REQU IREMENTS 10 8. SENSORS 12 9. KNOWING ACT DOOR ACTIVATION 16 10. ENTRAPMENT PROTE CTION . 17 11. SIGNAGE . 19 12. BREAK AWAY EGRE SS TEST FOR
12、 SWINGING , FOLDING AND SLIDIN G DOORS. . 20 APPENDIX A 23 APPENDIX B . 49 APPENDIX C . 53 APPENDIX D . 55 APPENDIX E . 56 51. GENERAL 1.1 Scope Requirements in this Standard apply to power operated doors for pedest rian use which open automatically when approached by pedestrians and some small vehi
13、cular traffic or by a knowing act. Included are provisions to reduce the chance of user injury or entrapment. Power operated doors for industrial or trained traffic are not covered in this Standard. 1.1.1 Where this Standard contains specifications relating to minimum or maximum dimensions of variou
14、s components of power operated doors for pedestrian use and some small vehicular traffic, such dimensions are included to provide user protection for what are, in the industry, standard application conditions. This Standard does not apply to custom installations. 1.2 This Standard does not apply to
15、power assist and low energy power operated doors. Refer to ANSI/BHMA A156.19 for Power Assist and Low Energy Power Operated Doors. 1.3 Required dimensions are expressed in US units first; approximate metric equivalents follow in parentheses. The following is a conversion chart for inches to approxim
16、ate mm equivalents where not given in the standard. TO CONVERT INCHES TO MILLIMETERS, MULTIPLY INCHES BY 25.4 TO CONVERT MILLIMETERS TO INCHES, MULTIPLY MILLIMETERS BY 0.03937. Inches mm Inches mm Inches mm Inches Mm 1/16 1.6 6 152 23 584 45 1143 1/4 6.35 7 178 24 610 47 1194 1/2 12.7 8 203 25 635 4
17、8 1219 3/4 19 9 229 26 660 49 1245 1 25.4 10 254 27 686 50 1270 1 1/2 38 11 279 28 711 51 1295 1 3/4 45 12 304 30 762 52 1321 1 1/2 38 13 330 31 787 53 1346 2 51 14 356 32 813 54 1372 2.26 57 15 381 33 838 55 1397 2 1/2 63 16 406 34 864 56 1422 3 76 17 432 36 914 57 1448 3 3/4 95 20 508 40 1016 58 1
18、473 4 102 21 533 41 1041 60 1524 5 127 22 559 43 1092 144 3658 1.4 American National Standards referenced in A156.10 are available from BHMA, or the American National Standards Institute, www.ansi.org. . 1.5 Tolerances Where only minus tolerances are given, the dimensions are permitted to be exceed
19、ed at the option of the manufacture rs. All values which do not carry specific tolerances or are not marked maximum or minimum shall have the following tolerances: Linear dimensions shall be + 1/16 in (1.6 mm). Pounds or pound force shall be + 2%. Degrees opening shall be + 2 degrees. Electrical mea
20、surements shall be + 2%. 1.6 Tests described in this standard are performed under laboratory conditions. Measurements shall be taken under neutral air pressure conditions. In actual usage, results vary because of installation, maintena nce and environmental conditions. 61.7 Doors used as fire doors
21、or smoke barriers have additional requirements not covered in this standard. 1.8 Where required by the authority having jurisdiction, products meeting the requirements of this Standard are required to comply with UL 325 -Fifth Edition June 2002, and be listed or labeled by a nationally recognized in
22、dependent testing laboratory and be under a periodic examination service. 1.9 Tests described in paragraphs 7.6 and 12 shall be performed under th e supervision of a nationally recognized independent testing laboratory on preproduction samples prior to acceptance of the design for production and sub
23、sequent installation. Production units shall be under an in-plant follow-up inspection service. 2. DEFINITIONS OF TERMS USE D IN THIS STANDARD 2.1 Active Area The area where a sensor or control mat detects presence or motion. 2.2 Activating Zone An area created by a sensor or control mat such that t
24、he door will open when the area is entered by (a) person(s) . 2.3 Activating Zone, Secondary An area created by a sensor or control mat such that the door will reactivate or reverse and remain active until the door is almost closed. 2.4 Automatic Door Operator A power operated mechanism that is atta
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BHMAA156102017POWEROPERATEDPEDESTRIANDOORSPDF

链接地址:http://www.mydoc123.com/p-542466.html