ASTM F2949-2012 Standard Specification for Pole Vault Box Collars《撑杆跳箱项圈的标准规范》.pdf
《ASTM F2949-2012 Standard Specification for Pole Vault Box Collars《撑杆跳箱项圈的标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM F2949-2012 Standard Specification for Pole Vault Box Collars《撑杆跳箱项圈的标准规范》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F2949 12Standard Specification forPole Vault Box Collars1This standard is issued under the fixed designation F2949; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses ind
2、icates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers minimum requirements ofsize, physical characteristics of materials, standard testingprocedures, labeling and identification of pole va
3、ult boxcollars.1.2 UnitsThe values stated in either SI units or inch-pound units are to be regarded separately as standard. Thevalues stated in each system may not be exact equivalents;therefore, each system shall be used independently of the other.Combining values from the two systems may result in
4、 non-conformance with the standard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limit
5、ations prior to use.2. Referenced Documents2.1 ASTM Standards:2F1292 Specification for Impact Attenuation of SurfacingMaterials Within the Use Zone of Playground Equipment3. Terminology3.1 Definitions:3.1.1 box collar arms, nthe two parts of the pole vault boxcollar to the left and right of the pole
6、 vault box. If the boxcollar has box collar wings, the wings are part of the box collararms.3.1.2 box collar body, nthe part of the pole vault boxcollar that pads the horizontal surfaces around the rim of thepole vault box and under the front buns.3.1.3 box collar cutout, nthe opening in the pole va
7、ult boxcollar above the pole vault box.3.1.4 box collar wing, nthe part of the box collar arm thatextends down the inner sidewall of the pole vault box. The boxcollar wings provide protection and help to hold the box collarin place.3.1.5 front buns, nthe parts of the pole vault landingsystem that pa
8、d the areas between the standard bases andaround the pole vault box.3.1.6 front opening, nthe opening at the front of the polevault box nearest the approach runway.3.1.7 pole bend cavity, nthe rearmost portion of the polevault box and box collar cutout in front of the strike platewhere the pole bend
9、s and rotates. The cavity is formed by thesidewalls and strike plate of the pole vault box, the rearmostpart of the pole slide, and inside edges of the box collar cutoutover the deepest part of the box where the pole slide meets thestrike plate.3.1.8 pole slide, nthe floor of the pole vault box that
10、 slantsdownward from its front boundary with the runway to its rearboundary with the back of the box. The tip of the vaulting poleslides on the pole slide to the strike plate.3.1.9 pole slide opening, nthe space between the ends ofthe box collar arms at the front of the pole vault box collar andabov
11、e the intersection of the runway with the pole slide.3.1.10 pole vault box, nthe trough at the end of the polevault runway. It has four sides: a downward sloping floor orpole slide, two sidewalls, and a strike plate. A vaulter directsthe lower end of the vaulting pole into the pole vault box. Thebac
12、k wall of pole vault box stops the forward motion of the endof the pole while allowing the pole to rotate about its end as thevaulter leaves the ground and completes a vault.3.1.11 pole vault box collar, na device used to offerimpact protection to pole vaulters in and around a pole vaultbox.3.1.12 s
13、idewalls, nthe left and right walls of the pole vaultbox.3.1.13 strike plate, nthe back wall of the pole vault box;the stopboard.4. Performance Requirements4.1 The average peak acceleration calculated from the lasttwo of a series of three impact tests for each impact test1This specification is under
14、 the jurisdiction of ASTM Committee F08 on SportsEquipment and Facilities and is the direct responsibility of Subcommittee F08.67 onPole Vault.Current edition approved Sept. 1, 2012. Published October 2012. DOI: 10.1520/F2949-12.2For referenced ASTM standards, visit the ASTM website, www.astm.org, o
15、rcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1location on the po
16、le vault box collar shall not exceed 200 gwhen impact tested in accordance with Section 9.4.2 The average HIC score calculated from the last two of aseries of three impact tests for each impact test location on thepole vault box collar shall not exceed 1150 when impact testedin accordance with Secti
17、on 9.5. Dimensions5.1 Minimum DimensionsA pole vault box collar shall beat least 122 cm (48 in.) wide and 146 cm (5712 in.) long. Thedistance from the rear edge of the box collar at its base to therear edge of the box collar cutout shall be at least 38 cm (15in.). At its uppermost surface, the box c
18、ollar shall cover theupper edges of each sidewall of the box from the front of thebox where the pole slide meets the runway to a point on the topedge of the sidewall no less than 20 cm (8 in.) forward of thetop of the strike plate. The box collar arms shall extend forwardat least 108 cm (4212 in.) f
19、rom the base of the rear edge of thebox collar cutout. (See Figs. 1 and 2.)5.2 Maximum ThicknessA pole vault box collar shall beno more than 10 cm (4 in.) thick.NOTE 1Minimum dimensions shown unless otherwise noted.FIG. 1 Plan View of Pole Vault Box CollarF2949 1225.3 Maximum Dimensions of Box Colla
20、r CutoutAt thebox collars uppermost surface in the vertical plane passingthrough the front edge of the pole slide, the horizontal distancefrom left to right across the box collar cutout shall be no morethan 58 cm (23 in.). At the horizontal plane of the runway, thehorizontal distance from left to ri
21、ght across the rear of the boxcollar cutout at the front of the bend cavity shall be no morethan 29 cm (1112 in.). The width across the base of the rearopening of the box collar cutout shall be no more than 42 cm(1612 in.). The width across the base of the front opening of thebox collar cutout shall
22、 be no more than 60 cm (24 in.). The boxcollar arms shall extend over the box beyond the upwardextended plane of the adjacent sidewall of the pole vault boxfrom a point no more than 20 cm (8 in.) forward from the topedge of the strike plate to the front of the box where the poleslide meets the runwa
23、y. (See Figs. 1 and 2.)5.4 Minimum Dimensions of Box Collar CutoutAt the boxcollars upper most surface in the vertical plane passingthrough the front edge of the pole slide, the horizontal distancefrom left to right across the box collar cutout shall be no lessthan 56 cm (22 in.). At and above the h
24、orizontal plane of therunway, the horizontal distance from left to right across the rearof the box collar cutout at the front of the bend cavity shall beno less than 23 cm (9 in.). The width across the base of the rearopening of the box collar cutout shall be no less than 41 cm (16in). The width acr
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF29492012STANDARDSPECIFICATIONFORPOLEVAULTBOXCOLLARS 撑杆 跳箱 项圈 标准规范 PDF

链接地址:http://www.mydoc123.com/p-539796.html