ASTM F2677-2008a(2013) Standard Specification for Electrically Insulating Aprons《电气绝缘档板的标准规范》.pdf
《ASTM F2677-2008a(2013) Standard Specification for Electrically Insulating Aprons《电气绝缘档板的标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM F2677-2008a(2013) Standard Specification for Electrically Insulating Aprons《电气绝缘档板的标准规范》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F2677 08a (Reapproved 2013)Standard Specification forElectrically Insulating Aprons1This standard is issued under the fixed designation F2677; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision.
2、A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers the acceptance testing ofelectrically insulating aprons for the protection of workersfrom incidental contac
3、t with live electrical apparatus or cir-cuits.1.2 The objective of this specification is to prescribe func-tion and performance criteria for insulating aprons that meet aminimum level of electrically insulating and physical perfor-mance characteristics.1.3 Three types of aprons are provided and are
4、designated asType I, non-resistant to ozone, Type II and Type III, resistant toozone.1.4 Six classes of insulating aprons, differing in electricalcharacteristics, are provided and are designated as Class 00,Class 0, Class 1, Class 2, Class 3, and Class 4.2. Referenced Documents2.1 ASTM Standards:2D1
5、048 Specification for Rubber Insulating BlanketsF819 Terminology Relating to Electrical Protective Equip-ment for WorkersF1742 Specification for PVC Insulating SheetingF2320 Specification for Rubber Insulating Sheeting3. Terminology3.1 Definitions:3.1.1 exposed areathe area of the electrically insul
6、atingapron that does not contain any stitching or fasteners.3.1.2 exposure zonethe area on the front of theelectrically-insulated apron 1 in. from the fasteners and stitch-ing or borders.3.1.3 For definitions of other terms, refer to TerminologyF819.4. Significance and Use4.1 This specification cove
7、rs the minimum electrical,chemical and physical properties, and design characteristics forinsulating aprons and the procedures by which properties are tobe determined. The purchaser may as his/her option, performor have performed any of these tests in order to verify anymanufacturer claim. Claims fo
8、r failure to meet the specificationare subject to verification by the manufacturer.4.2 The insulating materials used in aprons in this specifi-cation are designed for personal protection; therefore, whenauthorizing its use a margin of safety shall be allowed betweenthe maximum voltage at which it is
9、 used and the proof-testvoltage at which it is tested. The relationship between proof-test and the maximum voltage at which materials shall be usedis shown in Table 1.4.3 Work practices vary from user to user, depending uponmany factors. These factors may include, but are not limited to,operating sy
10、stem voltages, design, work procedures andtechniques, weather conditions, etc. Therefore, except for therestrictions set forth in this specification because of designlimitations, the use and maintenance of the equipment isbeyond the scope of this specification.4.4 It is common practice and the respo
11、nsibility of the userof this type of protective equipment to prepare completeinstructions and regulations to govern the correct and safe useof such equipment.5. Classification5.1 Insulating aprons covered under this specification shallbe designated as Type I, Type II or Type III; and as Class 00,Cla
12、ss 0, Class 1, Class 2, Class 3, or Class 4.5.1.1 Type I, non-resistant to ozone, made from a high-gradecis-1,4-polyisoprene rubber compound of natural or syntheticorigin, properly vulcanized.5.1.2 Type II, ozone-resistant, made of any elastomer orcombination of elastomeric compounds.5.1.3 Type III,
13、 ozone-resistant, made of any combination ofelastomer and thermoplastic polymers, elastic in nature.5.1.4 The class designation shall be based on the electricalproperties as shown in Table 1.1This specification is under the jurisdiction of ASTM Committee F18 onElectrical Protective Equipment for Wor
14、kers and is the direct responsibility ofSubcommittee F18.15 on Worker Personal Equipment.Current edition approved Sept. 1, 2013. Published September 2013. Originallyapproved in 2008. Last previous edition approved in 2008 as F2677 - 08a. DOI:10:1520/F2677-08AR13.2For referenced ASTM standards, visit
15、 the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959
16、. United States16. Ordering Information6.1 Orders for insulating aprons under this specificationshould include the following information:6.1.1 Type,6.1.2 Class, and6.1.3 Design or catalogue number.6.1.4 The listing of types and classes is not intended to meanall shall necessarily be available from m
17、anufacturers; it signi-fies only that, if made, they shall conform to the details of thisspecification.7. Manufacture and Marking7.1 The electrical insulating aprons shall be Type I, Type IIor Type III materials and shall be free of irregularities asdefined in Section 11. The electrical insulating a
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF26772008A2013STANDARDSPECIFICATIONFORELECTRICALLYINSULATINGAPRONS 电气 绝缘 档板 标准规范 PDF

链接地址:http://www.mydoc123.com/p-539248.html