1、Designation: F1541 02 (Reapproved 2011)1Standard Specification and Test Methods forExternal Skeletal Fixation Devices1This standard is issued under the fixed designation F1541; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the ye
2、ar of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEEditorial changes were made throughout in July 2012.1. Scope1.1 This specification provides a characterization of thede
3、sign and mechanical function of external skeletal fixationdevices (ESFDs), test methods for characterization of ESFDmechanical properties, and identifies needs for further devel-opment of test methods and performance criteria. The ultimategoal is to develop a specification, which defines performance
4、criteria and methods for measurement of performance-relatedmechanical characteristics of ESFDs and their fixation to bone.It is not the intention of this specification to define levels ofperformance or case-specific clinical performance of the de-vices, as insufficient knowledge is available to pred
5、ict theconsequences of the use of any of these devices in individualpatients for specific activities of daily living. Furthermore, it isnot the intention of this specification to describe or specifyspecific designs for ESFDs.1.2 This specification describes ESFDs for surgical fixationof the skeletal
6、 system. It provides basic ESFD geometricaldefinitions, dimensions, classification, and terminology; mate-rial specifications; performance definitions; test methods; andcharacteristics determined to be important to the in-vivoperformance of the device.1.3 This specification includes a terminology an
7、d classifi-cation annex and five standard test method annexes as follows:1.3.1 Classification of External FixatorsAnnex A1.1.3.2 Test Method for External Skeletal FixatorConnectorsAnnex A2.1.3.3 Test Method for Determining In-Plane CompressiveProperties of Circular Ring or Ring Segment BridgeElement
8、sAnnex A3.1.3.4 Test Method for External Skeletal Fixator JointsAnnex A4.1.3.5 Test Method for External Skeletal Fixator Pin Anchor-age ElementsAnnex A5.1.3.6 Test Method for External Skeletal FixatorSubassembliesAnnex A6.1.3.7 Test Method for External Skeletal Fixator/ConstructsSubassembliesAnnex A
9、7.1.4 A rationale is given in Appendix X1.1.5 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.6 The following safety hazards caveat pertains only to thetest method portions (Annex A2-Annex A6):1.7 This standard does not purpor
10、t to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2A938
11、Test Method for Torsion Testing of WireD790 Test Methods for Flexural Properties of Unreinforcedand Reinforced Plastics and Electrical Insulating MaterialsE4 Practices for Force Verification of Testing MachinesF67 Specification for Unalloyed Titanium, for SurgicalImplant Applications (UNS R50250, UN
12、S R50400, UNSR50550, UNS R50700)F90 Specification for Wrought Cobalt-20Chromium-15Tungsten-10Nickel Alloy for Surgical Implant Applica-tions (UNS R30605)F136 Specification for Wrought Titanium-6Aluminum-4Vanadium ELI (Extra Low Interstitial) Alloy for SurgicalImplant Applications (UNS R56401)F138 Sp
13、ecification for Wrought 18Chromium-14Nickel-2.5Molybdenum Stainless Steel Bar and Wire for SurgicalImplants (UNS S31673)F366 Specification for Fixation Pins and Wires1This specification is under the jurisdiction of ASTM Committee F04 onMedical and Surgical Materials and Devices and is the direct res
14、ponsibility ofSubcommittee F04.21 on Osteosynthesis.Current edition approved Oct. 1, 2011. Published October 2011. Originallypublished as F1541 94. Last previous edition approved in 2007 as F1541 02(2007)1. DOI: 10.1520/F1541-02R11E01.2For referenced ASTM standards, visit the ASTM website, www.astm.
15、org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.F543 Specif
16、ication and Test Methods for Metallic MedicalBone ScrewsF544 Reference Chart for Pictorial Cortical Bone ScrewClassification3F1058 Specification for Wrought 40Cobalt-20Chromium-16Iron-15Nickel-7Molybdenum Alloy Wire and Strip forSurgical Implant Applications (UNS R30003 and UNSR30008)F1264 Specifica
17、tion and Test Methods for IntramedullaryFixation DevicesF1472 Specification for Wrought Titanium-6Aluminum-4Vanadium Alloy for Surgical Implant Applications (UNSR56400)F1713 Specification for Wrought Titanium-13Niobium-13Zirconium Alloy for Surgical Implant Applications(UNS R58130)3. Terminology3.1
18、DefinitionsThe definitions of terms relating to exter-nal fixators are described in Annex A1.4. Classification4.1 External skeletal fixators are modular devices assembledfrom component elements.4.2 Test methods can address individual elements (forexample, anchorage elements, bridge elements); subass
19、embliesof elements (for example, connectors, joints, ring elements); orthe entire fixator.4.3 Tests of an entire assembled fixator may include thefixator alone, or alternatively, the fixator as anchored to arepresentation of the bone(s) upon which it typically would bemounted in clinical usage.5. Ma
20、terials5.1 All ESFDs made of materials that have an ASTMstandard shall meet those requirements given in ASTM Stan-dards listed in 2.1.6. Performance Considerations and Test Methods6.1 Individual ComponentsThe anchorage pins by whichan ESFD is attached to a skeletal member or members typicallyexperie
21、nce high flexural, or torsional loads, or both. Often, themajority of the overall compliance of an ESFD is in itsanchorage elements.Atest method for evaluating the mechani-cal performance of an ESFD anchorage element in either ofthese loading modes is described in Annex A5.6.2 Subassemblies of Eleme
22、nts:6.2.1 The sites of junction between ESFD anchorage ele-ments (for example, pins) and bridge elements (for example,rods) normally require specialized clamping or gripping mem-bers, known as connecting elements. Often, connecting ele-ments are subjected to high loads, especially moments, soadequac
23、y of their intrinsic mechanical stiffness, or strength, orboth, is critical to overall fixator performance. A test methodfor evaluating the mechanical performance of ESFD connectorelements is described in Annex A2.6.2.2 ESFDs involving ring-type bridge elements are usedwidely both for fracture treat
24、ment and for distraction osteo-genesis. The anchorage elements in such fixators usually arewires or thin pins, which pass transverse to the bone long axisand which are tensioned deliberately to control the longitudinalstiffness of the fixator. Tensioning these wires or pins causesappreciable compres
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF154120022011E1STANDARDSPECIFICATIONANDTESTMETHODSFOREXTERNALSKELETALFIXATIONDEVICES 骨骼 固定 装置 标准规范

链接地址:http://www.mydoc123.com/p-535101.html