ASTM E2634-2010 Standard Specification for Flat Wall Insulating Concrete Form (ICF) Systems《平壁绝热混凝土浇铸模板系统标准规范》.pdf
《ASTM E2634-2010 Standard Specification for Flat Wall Insulating Concrete Form (ICF) Systems《平壁绝热混凝土浇铸模板系统标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM E2634-2010 Standard Specification for Flat Wall Insulating Concrete Form (ICF) Systems《平壁绝热混凝土浇铸模板系统标准规范》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E2634 10Standard Specification forFlat Wall Insulating Concrete Form (ICF) Systems1This standard is issued under the fixed designation E2634; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A
2、 number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification is intended to apply to InsulatingConcrete Form (ICF) Systems that will act as permanentformwork for cast-in-place
3、reinforced concrete beams; lintels;exterior and interior, above and below grade bearing andnon-bearing walls; foundation; and retaining walls. The speci-fication is restricted to ICF Systems with a resultant uniformmonolithic concrete core.1.2 Products covered by the specification consists of molded
4、expanded polystyrene (EPS) insulation panels that are con-nected by cross ties to form the ICF System.1.3 This specification identifies test methods appropriate forestablishing ICF System performance in their primary functionas a stay in place concrete forming system. The use of ICFSystems covered b
5、y this specification shall be regulated bybuilding codes that address fire performance, structural perfor-mance or both. The fire performance of the material shall beaddressed through standard fire test methods established by theappropriate governing documents. The structural performancemust be addr
6、essed through design of concrete structures inaccordance with the appropriate Code requirements.1.4 Details of manufacturing procedures are beyond thescope of this specification.1.5 The values stated in SI units are to be regarded asstandard. The values given in parentheses are mathematicalconversio
7、ns to inch-pound units that are provided for informa-tion only and are not considered standard. For conversion tometric units other than those contained in this specification,refer to IEEE/ASTM SI 10.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its
8、 use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C203 Test Methods for Breaking Load and Flexural Prop-erties of Block-Ty
9、pe Thermal InsulationC390 Practice for Sampling and Acceptance of ThermalInsulation LotsC578 Specification for Rigid, Cellular Polystyrene ThermalInsulationC1363 Test Method for Thermal Performance of BuildingMaterials and Envelope Assemblies by Means of a HotBox ApparatusD635 Test Method for Rate o
10、f Burning and/or Extent andTime of Burning of Plastics in a Horizontal PositionD638 Test Method for Tensile Properties of PlasticsD732 Test Method for Shear Strength of Plastics by PunchToolD1622 Test Method for Apparent Density of Rigid CellularPlasticsD1761 Test Methods for Mechanical Fasteners in
11、 WoodD1929 Test Method for Determining Ignition Temperatureof Plastics3D2863 Test Method for Measuring the Minimum OxygenConcentration to Support Candle-Like Combustion ofPlastics (Oxygen Index)E8 Test Methods for Tension Testing of Metallic MaterialsE84 Test Method for Surface Burning Characteristi
12、cs ofBuilding MaterialsE90 Test Method for Laboratory Measurement of AirborneSound Transmission Loss of Building Partitions and Ele-mentsE119 Test Methods for Fire Tests of Building Constructionand MaterialsE283 Test Method for Determining Rate of Air LeakageThrough Exterior Windows, Curtain Walls,
13、and Doors1This specification is under the jurisdiction of ASTM Committee E06 onPerformance of Buildings and is the direct responsibility of Subcommittee E06.21on Serviceability.Current edition approved Oct. 1, 2010. Published December 2010. Originallyapproved in 2008. Last previous edition approved
14、in 2008 as E2634 08. DOI:10.1520/E2634-10.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Withdrawn. The las
15、t approved version of this historical standard is referencedon www.astm.org.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.Under Specified Pressure Differences Across the SpecimenE331 Test Method for Water Penetration of Exterior Wi
16、n-dows, Skylights, Doors, and Curtain Walls by UniformStatic Air Pressure DifferenceIEEE/ASTM SI 10 Standard for Use of the InternationalSystem of Units (SI): the Modern Metric System2.2 ISO/IEC Standards:4ISO/IEC Guide 65 General Requirements for Bodies Oper-ating Product Certification SystemsISO/I
17、EC Guide 17020 General Criteria for the Operation ofVarious Types of Bodies Performing InspectionISO/IEC Standard 17025 General Requirements for Com-petence of Test and Calibration Laboratories2.3 Other Standards:ACI 318 Building Code Requirements for Structural Con-crete5UL 1715 Fire Test of Interi
18、or Finish Material6NFPA 286 Method of Fire Test for Evaluating Contributionof Wall and Ceiling Interior Finish to Room Fire Growth7AISI NAS-01 North American Specification for the Designof Cold-formed Steel Structural Members, including 2005Supplement8ANSI/ASHRAE 90.1 Energy Standard for Buildings E
19、xceptLow-Rise Residential Buildings93. Terminology3.1 Definitions:3.1.1 cross tiesplastic or metal bridging comprised offlanges and webs that hold the EPS panels at a prescribeddistance and provide resistance to the concrete pressure. Theflanges may be used as attachment points for interior andexter
20、ior finishing materials.3.1.2 expanded polystyrenea type of foamed plasticformed by the expansion of polystyrene resin beads in amolding process.3.1.3 insulating concrete forms (ICFs)a structural stay-in-place concrete forming system, consisting of opposing EPSpanels, held parallel by means of cross
21、 ties and serves toprovide insulating characteristics. See Fig. 1.3.1.4 quality agencya quality agency is defined to be onethat: (1) Maintains accreditation as a Certification Organizationin accordance with ISO/IEC Guide 65 and as an InspectionAgency in accordance with ISO/IEC Guide 17020. The scope
22、of accreditations shall be consistent with the type of productbeing inspected. (2) Has access to the facilities and trainedtechnical personnel to verify that the grading, bonding, work-manship, and other characteristics of the products as deter-mined by inspection, sampling, and testing comply with
23、allapplicable requirements specified herein. (3) Has procedures tobe followed by its personnel in performance of the inspectionand testing. (4) Has no financial interest in, or is not financiallydependent upon, any single company manufacturing the prod-uct being inspected or tested. (5) Is not owned
24、, operated, orcontrolled by any such company.3.1.5 testing laboratorya testing laboratory is one that isaccredited as complying with ISO/IEC Standard 17025. Thescope of the laboratorys accreditation shall include the specifictype of testing being performed.4. Classification4.1 ICF Systems addressed
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME26342010STANDARDSPECIFICATIONFORFLATWALLINSULATINGCONCRETEFORMICFSYSTEMS 绝热 混凝土 浇铸 模板 系统 标准规范 PDF

链接地址:http://www.mydoc123.com/p-531589.html