1、Designation: D 6450 05An American National StandardStandard Test Method forFlash Point by Continuously Closed Cup (CCCFP) Tester1This standard is issued under the fixed designation D 6450; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revi
2、sion, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This flash point test method is a dynamic method anddepends on definite rates of temperature incre
3、ase. It is one ofthe many flash point test methods available, and every flashpoint test method, including this one, is an empirical method.NOTE 1Flash point values are not a constant physical-chemicalproperty of materials tested. They are a function of the apparatus design,the condition of the appar
4、atus used, and the operational procedure carriedout. Flash point can therefore only be defined in terms of a standard testmethod, and no general valid correlation can be guaranteed betweenresults obtained by different test methods or with test apparatus differentfrom that specified.1.2 This test met
5、hod covers the determination of the flashpoint of fuel oils, lube oils, solvents, and other liquids by acontinuously closed cup tester. The measurement is made on atest specimen of 1 mL.1.3 This test method utilizes a closed but unsealed cup withair injected into the test chamber.1.4 This test metho
6、d is suitable for testing samples with aflash point from 10 to 250C.NOTE 2Flash point determinations below 10C and above 250C canbe performed; however, the precision has not been determined below andabove these temperatures.1.5 If the users specification requires a defined flash pointmethod other th
7、an this test method, neither this test method norany other method should be substituted for the prescribedmethod without obtaining comparative data and an agreementfrom the specifier.1.6 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informat
8、iononly. Temperatures are in degrees Celsius, and pressure is inkilo-pascals.1.7 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determ
9、ine the applica-bility of regulatory limitations prior to use. Specific warningstatements appear throughout the standard.2. Referenced Documents2.1 ASTM Standards:2D 4057 Practice for Manual Sampling of Petroleum andPetroleum ProductsD 4177 Practice for Automatic Sampling of Petroleum andPetroleum P
10、roductsD 6299 Practice for Applying Statistical Quality AssuranceTechniques to Evaluate Analytical Measurement SystemPerformanceD 6300 Practice for Determination of Precision and BiasData for Use in Test Methods for Petroleum Products andLubricantsE 300 Practice for Sampling Industrial Chemicals2.2
11、ISO Standards:3ISO Guide 34 Quality Systems Guidelines for the Produc-tion of Reference MaterialsISO Guide 35 Certifications of Reference Material Gen-eral and Statistical Principles3. Terminology3.1 Definitions:3.1.1 dynamic, adjthe condition in which the vapor abovethe test specimen and the test s
12、pecimen are not in temperatureequilibrium at the time at which the ignition source is applied.3.1.2 flash point, nthe lowest temperature corrected to apressure of 101.3 kPa at which application of an ignitionsource causes the vapors of a specimen of the sample to ignitemomentarily under specified co
13、nditions of the test.3.1.2.1 DiscussionFor the purpose of this test method, thetest specimen is deemed to have flashed when the hot flame of1This test method is under the jurisdiction of ASTM Committee D02 onPetroleum Products and Lubricants and is the direct responsibility of SubcommitteeD02.08 on
14、Volatility.Current edition approved May 1, 2005. Published May 2005. Originallyapproved in 1999. Last previous edition approved in 1999 as D 645099.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandar
15、ds volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr
16、Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.the ignited vapor causes an instantaneous pressure increase ofat least 20 kPa inside the closed measuring chamber.44. Summary of Test Method4.1 The lid of the test chamber is regulated to a temperatureat least 18C below the e
17、xpected flash point.A1 6 0.1 mL testspecimen of a sample is introduced into the sample cup,ensuring that both specimen and cup are at a temperature atleast 18C below the expected flash point, cooling if necessary.The cup is then raised and pressed onto the lid of specifieddimensions to form the cont
18、inuously closed but unsealed testchamber with an overall volume of 4.0 6 0.2 mL.4.2 After closing the test chamber, the temperatures of thetest specimen and the regulated lid are allowed to equilibrate towithin 1C. Then the lid is heated at a prescribed, constant rate.For the flash tests, an arc of
19、defined energy is discharged insidethe test chamber at regular intervals. After each ignition, 1.5 60.5 mL of air is introduced into the test chamber to provide thenecessary oxygen for the next flash test. The pressure inside thecontinuously closed but unsealed test chamber remains atambient baromet
20、ric pressure, except for the short time duringthe air introduction and except at a flash point.4.3 After each arc, the instantaneous pressure increaseabove the ambient barometric pressure inside the test chamberis monitored. When the pressure increase exceeds a definedthreshold, the temperature at t
21、hat point is recorded as theuncorrected flash point.5. Significance and Use5.1 The flash point temperature is one measure of thetendency of the test specimen to form a flammable mixturewith air under controlled laboratory conditions. It is only oneof a number of properties that must be considered in
22、 assessingthe overall flammability hazard of a material.5.2 Flash point is used in shipping and safety regulations todefine flammable and combustible materials and classify them.This definition may vary from regulation to regulation. Consultthe particular regulation involved for precise definitions
23、ofthese classifications.5.3 This test method can be used to measure and describethe properties of materials in response to heat and an ignitionsource under controlled laboratory conditions and shall not beused to describe or appraise the fire hazard or fire risk ofmaterials under actual fire conditi
24、ons. However, results of thistest method may be used as elements of a fire risk assessment,which takes into account all of the factors that are pertinent toan assessment of the fire hazard of a particular end use.5.4 Flash point can also indicate the possible presence ofhighly volatile and flammable
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD64502005STANDARDTESTMETHODFORFLASHPOINTBYCONTINUOUSLYCLOSEDCUPCCCFPTESTER 连续 闪点 CCCFP 试验 测定 标准 方法

链接地址:http://www.mydoc123.com/p-522542.html