ASTM D56-2016 Standard Test Method for Flash Point by Tag Closed Cup Tester《用塔格闭式闪点试验器测定闪点的标准试验方法》.pdf
《ASTM D56-2016 Standard Test Method for Flash Point by Tag Closed Cup Tester《用塔格闭式闪点试验器测定闪点的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D56-2016 Standard Test Method for Flash Point by Tag Closed Cup Tester《用塔格闭式闪点试验器测定闪点的标准试验方法》.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D56 16Standard Test Method forFlash Point by Tag Closed Cup Tester1This standard is issued under the fixed designation D56; the number immediately following the designation indicates the year of originaladoption or, in the case of revision, the year of last revision. A number in parenth
2、eses indicates the year of last reapproval. A superscriptepsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.INTRODUCTIONTo ensure an acceptable precision, this dynamic flash point test m
3、ethod employs a prescribed rateof temperature rise for the material under test. The rate of heating may not in all cases give theprecision quoted in the test method because of the low thermal conductivity of certain materials. Toimprove the prediction of flammability, Test Method D3941, which utiliz
4、es a slower heating rate, wasdeveloped. Test Method D3941 provides conditions closer to equilibrium where the vapor above theliquid and the liquid are at about the same temperature. If a specification requires Test Method D56,do not change to Test Method D3941 or other test method without permission
5、 from the specifier.Flash point values are a function of the apparatus design, the condition of the apparatus used, andthe operational procedure carried out. Flash point can therefore only be defined in terms of a standardtest method, and no general valid correlation can be guaranteed between result
6、s obtained by differenttest methods, or with test apparatus different from that specified.1. Scope*1.1 This test method covers the determination of the flashpoint, by tag manual and automated closed testers, of liquidswith a viscosity below 5.5 mm2/s (cSt) at 40 C (104 F), orbelow 9.5 mm2/s (cSt) at
7、 25 C (77 F), and a flash point below93 C (200 F).1.1.1 For the closed-cup flash point of liquids with thefollowing properties: a viscosity of 5.5 mm2/s (cSt) or more at40 C (104 F); a viscosity of 9.5 mm2/s (cSt) or more at 25 C(77 F); a flash point of 93 C (200 F) or higher; a tendency toform a su
8、rface film under test conditions; or containingsuspended solids, Test Method D93 can be used.1.1.2 For cut-back asphalts refer to Test Methods D1310and D3143.NOTE 1The U.S. Department of Transportation (RSTA)2and U.S.Department of Labor (OSHA) have established that liquids with a flashpoint under 37
9、.8 C (100 F) are flammable as determined by this testmethod for those liquids that have a viscosity less than 5.5 mm2/s (cSt) at40 C (104 F) or 9.5 mm2/s (cSt) or less at 25 C (77 F), or do notcontain suspended solids or do not have a tendency to form a surface filmwhile under test. Other flash poin
10、t classifications have been established bythese departments for liquids using this test method.1.2 This test method can be used to measure and describethe properties of materials, products, or assemblies in responseto heat and flame under controlled laboratory conditions andcannot be used to describ
11、e or appraise the fire hazard or firerisk of materials, products, or assemblies under actual fireconditions. However, results of this test method can be used aselements of fire risk assessment that takes into account all ofthe factors that are pertinent to an assessment of the fire hazardof a partic
12、ular end use.1.3 Related standards are Test Methods D93, D1310,D3828, D3278, and D3941.1.4 The values stated in SI units are to be regarded asstandard. The values given in parentheses are for informationonly.1.5 WARNINGMercury has been designated by manyregulatory agencies as a hazardous material th
13、at can causecentral nervous system, kidney and liver damage. Mercury, orits vapor, may be hazardous to health and corrosive tomaterials. Caution should be taken when handling mercury andmercury containing products. See the applicable product Ma-terial Safety Data Sheet (MSDS) for details and EPAsweb
14、sitehttp:/www.epa.gov/mercury/faq.htmfor addi-tional information. Users should be aware that selling mercury1This test method is under the jurisdiction of ASTM Committee D02 onPetroleum Products, Liquid Fuels, and Lubricants and is the direct responsibility ofSubcommittee D02.08 on Volatility.Curren
15、t edition approved June 1, 2016. Published June 2016. Originallyapproved in 1918. Last previous edition approved in 2010 as D56 05 (2010). DOI:10.1520/D0056-16.2For information on United States Department of Transportation regulations, seeCodes of United States Regulation 49 CFR Chapter 1 and for in
16、formation on UnitedStates Department of Labor regulations, see Code of United States Regulation 29CFR Chapter XVII. Each of these items are revised annually and may be procuredfrom the Superintendent of Documents, Government Printing Office, Washington,DC 20402.*A Summary of Changes section appears
17、at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1and/or mercury containing products into your state or countrymay be prohibited by law.1.6 This standard does not purport to address all of thesafety concerns,
18、if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For specificwarning statements see 8.2, 8.3, 9.5, 12.5, and refer to MaterialSafety Dat
19、a Sheets.2. Referenced Documents2.1 ASTM Standards:3D93 Test Methods for Flash Point by Pensky-MartensClosed Cup TesterD1310 Test Method for Flash Point and Fire Point of Liquidsby Tag Open-Cup ApparatusD3143 Test Method for Flash Point of Cutback Asphalt withTag Open-Cup ApparatusD3278 Test Methods
20、 for Flash Point of Liquids by SmallScale Closed-Cup ApparatusD3828 Test Methods for Flash Point by Small Scale ClosedCup TesterD3941 Test Method for Flash Point by the EquilibriumMethod With a Closed-Cup ApparatusD4057 Practice for Manual Sampling of Petroleum andPetroleum ProductsD6299 Practice fo
21、r Applying Statistical Quality Assuranceand Control Charting Techniques to Evaluate AnalyticalMeasurement System PerformanceD6300 Practice for Determination of Precision and BiasData for Use in Test Methods for Petroleum Products andLubricantsE1 Specification for ASTM Liquid-in-Glass ThermometersE50
22、2 Test Method for Selection and Use of ASTM Stan-dards for the Determination of Flash Point of Chemicalsby Closed Cup Methods2.2 Federal Test Method Standards:4Method 1101, Federal Test Method Standard No. 791bMethod 4291, Federal Test Method Standard No. 141A2.3 ISO Standards:5Guide 34 General Requ
23、irements for the Competence of Ref-erence Material ProducersGuide 35 Certification of Reference MaterialsGeneral andStatistical Principles3. Terminology3.1 Definitions:3.1.1 flash point, nin flash point test methods, the lowesttemperature of the test specimen, adjusted to account forvariations in at
24、mospheric pressure from 101.3 kPa, at whichapplication of an ignition source causes the vapors of the testspecimen to ignite under specified conditions of test.3.1.1.1 DiscussionThe specimen is deemed to haveflashed when a flame appears and instantaneously propagatesitself over the entire surface of
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD562016STANDARDTESTMETHODFORFLASHPOINTBYTAGCLOSEDCUPTESTER 用塔格闭式 闪点 试验 测定 标准 方法 PDF

链接地址:http://www.mydoc123.com/p-511874.html