1、Designation: C610 11C610 15Standard Specification forMolded Expanded Perlite Block and Pipe ThermalInsulation1This standard is issued under the fixed designation C610; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of las
2、t revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.1. Scope1.1 This specification covers molded ex
3、panded perlite block, fittings, and pipe thermal insulation intended for use on surfaceswith temperatures between 80 to 1200F (27 to 649C).1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematicalconversions to SI units that are provid
4、ed for information only and are not considered standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability
5、 of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C165 Test Method for Measuring Compressive Properties of Thermal InsulationsC168 Terminology Relating to Thermal InsulationC177 Test Method for Steady-State Heat Flux Measurements and Thermal Transmission Properties by
6、 Means of theGuarded-Hot-Plate ApparatusC203 Test Methods for Breaking Load and Flexural Properties of Block-Type Thermal InsulationC302 Test Method for Density and Dimensions of Preformed Pipe-Covering-Type Thermal InsulationC303 Test Method for Dimensions and Density of Preformed Block and BoardTy
7、pe Thermal InsulationC335C335/C335M Test Method for Steady-State Heat Transfer Properties of Pipe InsulationC356 Test Method for Linear Shrinkage of Preformed High-Temperature Thermal Insulation Subjected to Soaking HeatC390 Practice for Sampling and Acceptance of Thermal Insulation LotsC411 Test Me
8、thod for Hot-Surface Performance of High-Temperature Thermal InsulationC421 Test Method for Tumbling Friability of Preformed Block-Type and Preformed Pipe-Covering-Type Thermal InsulationC450 Practice for Fabrication of Thermal Insulating Fitting Covers for NPS Piping, and Vessel LaggingC518 Test Me
9、thod for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter ApparatusC585 Practice for Inner and Outer Diameters of Thermal Insulation for Nominal Sizes of Pipe and TubingC795 Specification for Thermal Insulation for Use in Contact with Austenitic Stainless SteelC1045 Pract
10、ice for Calculating Thermal Transmission Properties Under Steady-State ConditionsC1058C1058/C1058M Practice for Selecting Temperatures for Evaluating and Reporting Thermal Properties of ThermalInsulationC1616 Test Method for Determining the Moisture Content of Organic and Inorganic Insulation Materi
11、als by WeightC1763 Test Method for Water Absorption by Immersion of Thermal Insulation MaterialsE84 Test Method for Surface Burning Characteristics of Building MaterialsE136 Test Method for Behavior of Materials in a Vertical Tube Furnace at 750C1 This specification is under the jurisdiction of ASTM
12、 Committee C16 on Thermal Insulation and is the direct responsibility of Subcommittee C16.20 on HomogeneousInorganic Thermal Insulations.Current edition approved Sept. 1, 2011May 1, 2015. Published December 2011August 2015. Originally approved in 1967. Last previous edition approved in 20102011as C6
13、10 10.C610 11. DOI: 10.1520/C0610-11.10.1520/C0610-15.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This do
14、cument is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions a
15、s appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States13. Standard Shapes, Sizes, and Dimensions3.1 Molded exp
16、anded perlite block, fitting, and pipe thermal insulation shall be as follows:3.1.1 BlockBlock shall be furnished in lengths of either 36 or 39.4 in. (914 or 1000 mm), widths of 6 in. (152 mm), 12 in.(305 mm), 18 in. (457 mm), or 24 in. (610 mm), and in thickness from 112 to 6 in. (38 to 152 mm) in
17、increments of 12 in. (13mm).3.1.2 Pipe InsulationMolded expanded perlite pipe insulation shall be supplied either as hollow cylindrical shapes split in halflengthwise (in a plane including the cylindrical axis) or curved segments. The pipe insulation shall be furnished in sections orsegments in leng
18、ths of either 36 or 39.4 in. (914 or 1000 mm) to fit standard sizes of pipe and tubing, and in nominal thicknessfrom 1 to 4 in. (25 to 102 mm) in 12-in. (13-mm) increments. Inner and outer diameters of multilayer construction shall bespecified. Inner and outer diameters shall be in accordance with t
19、hose standard dimensions specified in Practice C585. Sinceoutside diameter tolerances differ between individual manufacturing processes, it is acceptable to have pipe insulation furnishedin two or more layers nested by the manufacturer. The purchaser shall consult the manufacturer for specific requi
20、rements.3.1.3 FittingsMolded (expanded insulation fittings shall conform to the inner and outer diameters in accordance with PracticeC585. Mitered fittings shall be in accordance with Practice C450.4. Description4.1 Compositionmolded expanded perlite block, fitting, and pipe thermal insulation shall
21、 be composed principally ofexpanded perlite and silicate binders may contain reinforcing fibers.5. Dimensional Tolerances5.1 GeneralThe average tolerances for length, width, and thickness shall comply with the requirements shown in Table 1.5.2 Pipe InsulationThe following additional tolerances apply
22、 to perlite pipe insulation supplied as half sections:5.2.1 Fit and ClosureWhen fitted to the appropriate size pipe, the longitudinal seam of the pipe insulation shall close to within116 in. (1.6 mm) along the entire length of the section.5.2.2 ConcentricityThe inner bore of the pipe insulation shal
23、l be concentric with the outer cylindrical surface. The deviationfrom concentricity shall not exceed 18 in. (3.2 mm) or 5 % of the wall thickness, whichever is greater.5.2.3 Half-Section BalanceThe plane formed by the split between half sections shall include the cylindrical axis. Deviationof the sp
24、lit plane from the cylinder axis over the 36 or 39.4-in. (914 or 1000-mm) length shall not exceed 18 in. (3.2 mm).6. Workmanship, Finish, and Appearance6.1 Since some requirements for this material are not easily defined by a numerical value, the insulation shall not have visibledefects that will ad
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC6102015STANDARDSPECIFICATIONFORMOLDEDEXPANDEDPERLITEBLOCKANDPIPETHERMALINSULATION 膨胀 珍珠岩 绝热材料 标准

链接地址:http://www.mydoc123.com/p-507756.html