ATIS 0600016-2008 Remote End POTS Splitter Requirements.pdf
《ATIS 0600016-2008 Remote End POTS Splitter Requirements.pdf》由会员分享,可在线阅读,更多相关《ATIS 0600016-2008 Remote End POTS Splitter Requirements.pdf(25页珍藏版)》请在麦多课文档分享上搜索。
1、 AMERICAN NATIONAL STANDARD FOR TELECOMMUNICATIONS ATIS-0600016.2008(R2013) Remote End POTS Splitter Requirements As a leading technology and solutions development organization, ATIS brings together the top global ICT companies to advance the industrys most-pressing business priorities. Through ATIS
2、 committees and forums, nearly 200 companies address cloud services, device solutions, emergency services, M2M communications, cyber security, ehealth, network evolution, quality of service, billing support, operations, and more. These priorities follow a fast-track development lifecycle from design
3、 and innovation through solutions that include standards, specifications, requirements, business use cases, software toolkits, and interoperability testing. ATIS is accredited by the American National Standards Institute (ANSI). ATIS is the North American Organizational Partner for the 3rd Generatio
4、n Partnership Project (3GPP), a founding Partner of oneM2M, a member and major U.S. contributor to the International Telecommunication Union (ITU) Radio and Telecommunications sectors, and a member of the Inter-American Telecommunication Commission (CITEL). For more information, visit . AMERICAN NAT
5、IONAL STANDARD Approval of an American National Standard requires review by ANSI that the requirements for due process, consensus, and other criteria for approval have been met by the standards developer. Consensus is established when, in the judgment of the ANSI Board of Standards Review, substanti
6、al agreement has been reached by directly and materially affected interests. Substantial agreement means much more than a simple majority, but not necessarily unanimity. Consensus requires that all views and objections be considered, and that a concerted effort be made towards their resolution. The
7、use of American National Standards is completely voluntary; their existence does not in any respect preclude anyone, whether he has approved the standards or not, from manufacturing, marketing, purchasing, or using products, processes, or procedures not conforming to the standards. The American Nati
8、onal Standards Institute does not develop standards and will in no circumstances give an interpretation of any American National Standard. Moreover, no person shall have the right or authority to issue an interpretation of an American National Standard in the name of the American National Standards
9、Institute. Requests for interpretations should be addressed to the secretariat or sponsor whose name appears on the title page of this standard. CAUTION NOTICE: This American National Standard may be revised or withdrawn at any time. The procedures of the American National Standards Institute requir
10、e that action be taken periodically to reaffirm, revise, or withdraw this standard. Purchasers of American National Standards may receive current information on all standards by calling or writing the American National Standards Institute. Notice of Disclaimer Series G: Transmission Systems and Medi
11、a, Digital Systems and Networks, Digital transmission systems - Access networks, Very high speed digital subscriber line transceivers 2 (VDSL2)410 ATIS-0600601.1999(R2009) - Integrated Services Digital Network (ISDN) Basic Access Interface for Use on Metallic Loops for Application on the Network Sid
12、e of the NT (Layer 1 Specification).111 T1.TR.28-1994, High-Bit-Rate Digital Subscriber Line (HDSL).11This document is available from the Alliance for Telecommunications Industry Solutions (ATIS), 1200 G Street N.W., Suite 500, Washington, DC 20005. 2This document is available from the Institute of
13、Electrical and Electronics Engineers (IEEE). 3Telcordia documents are available from Industry Direct Sales, Telcordia, 8 Corporate Place, PYA 3A-184,Piscataway,NJ,8854-4156,or: . 4This document is available from the International Telecommunications Union. ATIS-06000016.2008 3 3 DEFINITIONS, ACRONYMS
14、, voice band and DSL band. Testing shall not be performed in the transition band. The transition band is defined between 4 kHz and Fmin, where Fmin is defined per Table 7. However, it is expected that the LPF shall be well behaved in this area (i.e., the amplitude response is monotonically decreasin
15、g from 4 kHz to Fmin) 4.2.2 Balanced Terminations All testing shall be done in a BALANCED (i.e. metallic) method. Test equipment with unbalanced connections may be used as long as the resultant measurement maintains balance. Balun transformers are often used on test equipment with unbalanced connect
16、ions. 4.3 ZHP-r and ZNL-r Impedances Defined To facilitate testing of the DSL splitter independently of the actual modem or specific vendor, ZHP-r is defined to allow proper termination of the DSL port during voice band testing for the splitter at the remote customer end. (See Figure 6) The ZHP-r is
17、 valid only for voice band frequencies. ZNL-r is defined as lumped impedance models of loops for remote end splitter design. The requirements for ZNL-r are shown in Figure 7. ATIS-06000016.2008 8 0.10 F 0.12 F0.10 F 0.12 F0.47 mH100 OhmComponent Tolerances Capacitors = 2.5%, Resistors = 1%, Coils =
18、5% Figure 6: ZHP-r of DSL port termination for voice band testing 100 nF348 Ohm1330 OhmComponent Tolerances Capacitors = 2.5%, Resistors = 1% Figure 7: ZNL-r of POTS Port Termination for Voice Band Testing 4.4 MAINTENANCE TEST SIGNATURES (MTS) If the maintenance test signatures are provided for the
19、remote end splitter, they shall be as shown in Figure 8. In order to allow the DSL splitter to be managed by the network operational support systems and to be identified by metallic loop test systems, the remote end DSL splitter function may contain a signature that is activated by the metallic test
20、 systems. The signature is unique for all North American remote end DSL splitters. The signature is designed to be active only during the maintenance mode and will not interfere with normal operation of the circuit. The signature is located on the POTS side of the LPF function protecting the DSL ban
21、d frequencies from the non-linear effects of the diodes. ATIS-06000016.2008 9 0.47 F, 10%33 kOhm , 1%6.8V, 10%TipRingFigure 8: Maintenance Test Signature 4.5 Signaling Requirements Unless otherwise noted, all of the requirements in this standard shall be met in the presence of all of the following:
22、POTS loop currents from 0 mA to 100 mA; POTS tip-to-ring DC voltages of 0 VDC to -60 VDC; POTS ringing signals that meet the criteria in 4.5.1. Compliance with the loop current range above may be demonstrated by meeting the requirements of this standard with loop currents of 0, 20, 40, 60, 80 and 10
23、0 mA (+/- 1 mA for all values) with a -60 VDC +/- 1 VDC source. Compliance with the DC voltage range above may be demonstrated by meeting the requirements of this standard with DC voltages of 0, -20, -40, and -60 VDC (+/- 1 VDC for all values) with 40 mA +/- 1 mA of loop current. 4.5.1 Applied Ringi
24、ng Signals For the purposes of meeting the ringing signal requirement in section 4.5, applied ringing signals shall meet the following criteria: The DC component of the ringing signal shall be between 0 VDC and -60 VDC. The AC component of the ringing signal shall be 20 Hz +/- 1 Hz. The AC component
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ATIS06000162008REMOTEENDPOTSSPLITTERREQUIREMENTSPDF

链接地址:http://www.mydoc123.com/p-541244.html