ASME MFC-22-2007 Measurement of Liquid by Turbine Flowmeters《涡轮流量计测量液体》.pdf
《ASME MFC-22-2007 Measurement of Liquid by Turbine Flowmeters《涡轮流量计测量液体》.pdf》由会员分享,可在线阅读,更多相关《ASME MFC-22-2007 Measurement of Liquid by Turbine Flowmeters《涡轮流量计测量液体》.pdf(24页珍藏版)》请在麦多课文档分享上搜索。
1、Measurementof Liquid by Turbine FlowmetersAN AMERICAN NATIONAL STANDARDASME MFC-222007Intentionally left blank ASME MFC-222007Measurementof Liquid byTurbineFlowmetersAN AMERICAN NATIONAL STANDARDThree Park Avenue New York, NY 10016Date of Issuance: April 14, 2008This Standard will be revised when th
2、e Society approves the issuance of a new edition. There willbe no addenda issued to this edition.ASME issues written replies to inquiries concerning interpretations of technical aspects of thisdocument. Periodically certain actions of the ASME MFC Committee may be published as Cases.Cases and interp
3、retations are published on the ASME Web site under the Committee Pages athttp:/cstools.asme.org as they are issued.ASME is the registered trademark of The American Society of Mechanical Engineers.This code or standard was developed under procedures accredited as meeting the criteria for American Nat
4、ionalStandards. The Standards Committee that approved the code or standard was balanced to assure that individuals fromcompetent and concerned interests have had an opportunity to participate. The proposed code or standard was madeavailable for public review and comment that provides an opportunity
5、for additional public input from industry, academia,regulatory agencies, and the public-at-large.ASME does not “approve,” “rate,” or “endorse” any item, construction, proprietary device, or activity.ASME does not take any position with respect to the validity of any patent rights asserted in connect
6、ion with anyitems mentioned in this document, and does not undertake to insure anyone utilizing a standard against liability forinfringement of any applicable letters patent, nor assume any such liability. Users of a code or standard are expresslyadvised that determination of the validity of any suc
7、h patent rights, and the risk of infringement of such rights, isentirely their own responsibility.Participation by federal agency representative(s) or person(s) affiliated with industry is not to be interpreted asgovernment or industry endorsement of this code or standard.ASME accepts responsibility
8、 for only those interpretations of this document issued in accordance with the establishedASME procedures and policies, which precludes the issuance of interpretations by individuals.No part of this document may be reproduced in any form,in an electronic retrieval system or otherwise,without the pri
9、or written permission of the publisher.The American Society of Mechanical EngineersThree Park Avenue, New York, NY 10016-5990Copyright 2008 byTHE AMERICAN SOCIETY OF MECHANICAL ENGINEERSAll rights reservedPrinted in U.S.A.CONTENTSForeword ivCommittee Roster . vCorrespondence With the MFC Committee .
10、 vi1 Scope . 12 References . 13 Definitions and Symbols 14 Principle of Measurement. 25 Selection of Meter and Accessory Equipment for Flow Rate Determination . 26 Installation 47 Meter Performance . 78 Operation and Maintenance . 89 Measurement Uncertainty. 10Figures1 Typical Meter Performance Curv
11、e . 22 Schematic of Liquid Turbine Meter (Upstream-Downstream Stator) . 33 Schematic of Liquid Turbine Meter (Cantilever Stator) . 44 Typical Turbine Meter System . 45 Typical Installation of an Upstream Flow Conditioner 56 Typical Performance Curve of Turbine Meter Showing Effect of Back Pressure 6
12、Tables1 Symbols 32 Results of the Uncertainty Example 12iiiFOREWORDTurbine flowmeters cover a family of devices with varying designs that depend on rotatingblades for the measurement of fluid velocity. This Standard is for liquid turbine meters and isnot intended for gas turbine meters. The primary
13、purpose of the liquid turbine flowmeter is tomeasure flowing volume. The flowing volume can be recalculated as volume at a specific set ofconditions or as mass flow with the proper addition of additional measurements that can includetemperature, pressure, and analytical devices.The liquid flow turbi
14、ne meters can be used for process monitoring, control, and custody transferapplications.Suggestions for improvement of this Standard are welcome. They should be sent to: TheAmerican Society of Mechanical Engineers, Attn: Secretary, MFC Standards Committee, ThreePark Avenue, New York, NY 10016-5990.F
15、ollowing approval by the Standards Committee and the ASME Board, this Standard wasapproved as an American National Standard on June 8, 2007, with the designationASME MFC-222007.ivASME MFC COMMITTEEMeasurement of Fluid Flow in Closed Conduits(The following is the roster of the Committee at the time o
16、f approval of this Standard.)STANDARDS COMMITTEE OFFICERSR. J. DeBoom, ChairZ. D. Husain, Vice ChairC. J. Gomez, SecretarySTANDARDS COMMITTEE PERSONNELC. J. Blechinger, Member Emeritus, ConsultantR. M. Bough, Rolls-Royce Motor CarsG. P. Corpron, ConsultantR. J. DeBoom, ConsultantR. H. Fritz, Corresp
17、onding Member, Lonestar Measurement however, they shouldnot contain proprietary names or information.Requests that are not in this format will be rewritten in this format by the Committee priorto being answered, which may inadvertently change the intent of the original request.ASME procedures provid
18、e for reconsideration of any interpretation when or if additionalinformation that might affect an interpretation is available. Further, persons aggrieved by aninterpretation may appeal to the cognizant ASME Committee or Subcommittee. ASME does not“approve,” “certify,” “rate,” or “endorse” any item,
19、construction, proprietary device, or activity.Attending Committee Meetings. The MFC Committee regularly holds meetings, which are opento the public. Persons wishing to attend any meeting should contact the Secretary of theMFC Standards Committee.viASME MFC-222007MEASUREMENT OF LIQUID BY TURBINE FLOW
20、METERS1 SCOPEThis Standard describes the criteria for the applicationof a turbine flowmeter with a rotating blade for themeasurement of liquid flows through closed conduitrunning full.The standard discusses the following:(a) considerations regarding the liquids to bemeasured(b) turbine flowmeter sys
21、tem(c) installation requirements(d) design specifications(e) the maintenance, operation, and performance(f) measurement uncertaintiesThis Standard does not address the details of theinstallation of accessory equipment used to measurepressure, temperature, and/or density for the accuratedetermination
22、 of mass or base volumes, or those accesso-ries used to automatically compute mass or basevolumes.2 REFERENCESThe following is a list of publications referenced in thisStandard. Unless otherwise specified, the latest editionshall apply.ANSI/NCSL Z540.2-1997 (R2002), U.S. Guide toExpression of Uncert
23、ainty in MeasurementPublisher: NCSL International, 2995 Wilderness Place,Suite 107, Boulder, CO 80301-5404ASME MFC-1M, Glossary of Terms Used in theMeasurement of Fluid Flows in PipesPublisher: The American Society of MechanicalEngineers (ASME), Three Park Avenue, New York,NY 10016-5990; Order Depar
24、tment: 22 Law Drive,P.O. Box 2300, Fairfield, NJ 07007-2300ISO Guide to the expression of uncertainty inmeasurementPublisher: International Organization forStandardization (ISO), 1 ch. de la Voie-Creuse, Casepostale 56, CH-1211, Geneve 20, Switzerland/SuisseNIST Technical Note 1297 (TN 1297), Guidel
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASMEMFC222007MEASUREMENTOFLIQUIDBYTURBINEFLOWMETERS 涡轮流量计 测量 液体 PDF

链接地址:http://www.mydoc123.com/p-456720.html