SAE AS 5304-2011 Standard Specification for Turbine Flowmeters《对涡轮流量计的标准规格》.pdf
《SAE AS 5304-2011 Standard Specification for Turbine Flowmeters《对涡轮流量计的标准规格》.pdf》由会员分享,可在线阅读,更多相关《SAE AS 5304-2011 Standard Specification for Turbine Flowmeters《对涡轮流量计的标准规格》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、 _ SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirely voluntary, and its applicability and suitability for any particular use, including any patent infringement arising ther
2、efrom, is the sole responsibility of the user.” SAE reviews each technical report at least every five years at which time it may be revised, reaffirmed, stabilized, or cancelled. SAE invites your written comments and suggestions. Copyright 2017 SAE International All rights reserved. No part of this
3、publication may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: +1 724-776-49
4、70 (outside USA) Fax: 724-776-0790 Email: CustomerServicesae.org SAE WEB ADDRESS: http:/www.sae.org SAE values your input. To provide feedback on this Technical Report, please visit http:/standards.sae.org/AS5304 AEROSPACE STANDARD AS5304 Issued 2011-06 Reaffirmed 2017-02 Standard Specification for
5、Turbine Flowmeters RATIONALE AS5304 has been reaffirmed to comply with the SAE five-year review policy. 1. SCOPE This is a SAE Standard specification with minimum performance characteristics for Turbine Flowmeter (TFM) that pertains only to sizes from to 2 inches. The utilization of TFM is for hydro
6、carbon liquid fuel volumetric flow measurements. This Standard specifically excludes smart electronics in accomplishing the defined performance objectives. Users of this Standard should specify other TFM characteristics required to satisfy their application and utilization in operational environment
7、. A User should understand fit and function of the TFM and define end user specific fit and function requirements. The TFM should be calibrated by the manufacturer should be based upon end user requirements and presented as Roshko versus Strouhal at a reference temperature. The Supplier shall be pre
8、pared to show evidence to User that the device demonstrates compliance with all requirements identified in this Standard. 2. REFERENCES The following publications form a part of this document to the extent specified herein. The latest issue of SAE publications shall apply. The applicable issue of th
9、e other publications shall be the issue in effect on the date of the purchase order. In the event of conflict between the text of this document and references cited herein, the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unles
10、s a specific exemption has been obtained. 2.1 SAE Publications Available from SAE International, 400 Commonwealth Drive, Warrendale, PA 15096-0001, Tel: 877-606-7323 (inside USA and Canada) or 724-776-4970 (outside USA), www.sae.org. ARP4990 Turbine Flowmeter Fuel Flow Calculations 2.2 API Publicati
11、ons Available from American Petroleum Institute, 1220 L Street, NW, Washington, DC 20005-4070, Tel: 202-682-8000, http:/api-ec.api.org. API ANSI Z11.299/API-2534 Turbine flow meters Section 2 2.3 ISO Publications Available from International Organization for Standardization, 1, rue de Varembe, Case
12、postale 56, CH-1211 Geneva 20, Switzerland, Tel: +41-22-749-01-11, www.iso.org.ISO 4406 First Edition, 1987-12-15 (E) 2.4 NIST Publications Available from National Institute of Standards and Technology, 100 Bureau Drive, Stop 1070, Gaithersburg, MD 20899-1070, Tel: 301-975-6478, www.nist.gov.NIST Te
13、chnical Note 1297 1994 Edition, titled “ Guidelines for evaluating and expressing the Uncertainty of NIST Measurement Results” 2.5 U.S. Governement Publications Available from the Document Automation and Production Service (DAPS), Building 4D, 700 Robbins Avenue, Philadelphia, PA 19111-5094, Tel: 21
14、5-697-9495, https:/assist.daps.dla.mil/quicksearch/.MIL-PRF-7024E Performance Specification, Calibrating Fluids, Aircraft Fuel System Components, 01 October 1997. Superseding MIL-C-7024D 30 August 1990 2.6 Other Publications Mattingly, G. E., Titled “The Characterization of a Piston Displacement-Typ
15、e Flowmeter Calibration Facility and the Calibration and Use of Pulsed Output Type Flowmeters”, Journal of Research of the National Institute of Standards and Technology, Volume 97, Number 5, September-October 1992, pp. 509-531. 3. DEFINITIONS K-FACTOR: A traditional representation of TFM characteri
16、stics of a flowmeter shown as cycles/US-gal or cycles/L versus output frequency divided by kinematic viscosity (f/v). This is provided that the fluid is operated at the same temperature calibrated TIME CONSTANT: The time required for the TFM indication to reach 63.2% of the final value after the app
17、lication of a step input flow. STROUHAL NUMBER (St) : Dimension-less in basic form is equal to (output frequency) * (reference diameter of meter) 3. This number compensates for temperature change and is referenced to a standard temperature. ROSHKO NUMBER (Ro): Dimension-less in basic form is equal t
18、o (output frequency / kinematic viscosity) * (reference diameter of meter) 2. This compensates for temperature change when referenced to a standard temperature._SAE INTERNATIONAL AS5304 2 of 64. TECHNICAL REQUIREMENTS Useable Range: Modulated Carrier Pickup (Pickoff): Minimum 15:1 turndown from the
19、maximum flow rate to the minimum flowrate for the TFM which is defined as the breakpoint of the StRo curve from the universal viscosity curve. (Ref Mattingly, G. E., Titledpaper and SAE ARP4990 Titled “Turbine Flowmeter Fuel Flow Calculations” Re-Issued 2002) Magnetic Pickup: Minimum 10:1 turndown f
20、rom the maximum flow rate to the minimum flowrate for the TFM which is defined as the breakpoint of the StRo curve from the universal viscosity curve. (Ref Mattingly, G. E., Titledpaper and SAE ARP4990 Titled “Turbine Flowmeter Fuel Flow Calculations” Re-Issued 2002) Calibration Data Uncertainty: Su
21、pplier Calibration Stand shall have an uncertainty less than 0.05% of flow rate and traceable to NIST or equivalent National Standards Laboratory for the calibration data. TFM Uncertainty: r 0.15% of flow rate over the useable range as defined herein with an approximate viscosity of 1.12 centistokes
22、 at 80 0F (26.7 0C) in MIL-PRF-7024 (ASTM 540C) Type II liquid or mutually agreed calibration fluid substitute.TFM Linearity: The meter may only be linear for specific fluids. The linear range may be specified if the fluid is MIL-PRF-7024 (ASTM 540C) Type II liquid or equivalent calibration fluid su
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEAS53042011STANDARDSPECIFICATIONFORTURBINEFLOWMETERS 涡轮流量计 标准 规格 PDF

链接地址:http://www.mydoc123.com/p-1024818.html