ASHRAE IJHVAC 16-1-2010 HVAC&R Research《《HVAC&R研究》》.pdf
《ASHRAE IJHVAC 16-1-2010 HVAC&R Research《《HVAC&R研究》》.pdf》由会员分享,可在线阅读,更多相关《ASHRAE IJHVAC 16-1-2010 HVAC&R Research《《HVAC&R研究》》.pdf(107页珍藏版)》请在麦多课文档分享上搜索。
1、Volume 16, Number 1, January 2010An International Journal of Heating, Ventilating,Air-Conditioning and Refrigerating ResearchAmerican Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.Volume 16, Number 1, January 2010HVAC accepted October 9, 2009A novel cooling design featuring a
2、 two-stage expansion process is proposed in this study. With-out any help from insulation, the design can minimize or even entirely eliminate condensate formation outside the cold-plate surface even for a very low evaporation temperature. The design incorporates a double-pipe inlet/outlet and a two-
3、container cold plate, and its perfor-mance is compared to a conventional cold plate. For the conventional cold plate, the outlet pressure/temperature hold quite steadily at a light heat load, and the outlet pressure/temperatureshows a substantial rise when the refrigerant is completely evaporated. T
4、he outlet pressure/ temperature of the condensate-free cold plate shows an opposite trend at a heavy heat loading. The benefit of this characteristic is that the wall surface temperature and the outlet tempera-ture of the cold plate can be maintained comparatively more steady than the conventional c
5、old plate. INTRODUCTIONCurrently complementary metal-oxide semiconductor (CMOS) chip technologies act as the major class of integrated circuits and are widely applied in microprocessors, microcontrollers, static random-access memory (RAM), and other digital logic circuits. With the ongoing rise of c
6、apability, there is a strong demand for cooling to ensure the performance of microprocessors, microcontrollers, static RAM, and other digital logic circuits. In particular, it is known that the performance of CMOS can be drastically improved if the temperature can be further reduced. There are many
7、advantages (Ghibaudo et al. 1992), e.g., higher carrier mobility, higher satura-tion velocity, better turn-on capabilities (sub-threshold slope), latch-up immunity, improved reliability due to activated degradation processes, reduced power consumption, a decrease in leakage currents, a lowering of i
8、nterconnection resistance, increased thermal conductivity, and a reduction of thermal noise, in addition to the low temperature operation. Moreover, it is well known that operating semiconductor devices at lower temperatures leads to conspicuously improved performance (Taut et al. 1997). This is bec
9、ause of faster switching times of semiconductor devices and increased circuit speeds due to lower electrical resistance of interconnecting materials at low-temperature operations (Balestra and Ghibaudo 1994). Depend-ing on the doping characteristics, attainable performance improvements range from 1%
10、 to 3% for every 10C (50F) lower transistor temperature (Phelan 2001). However, in addition to the phys-ical limit of shrinking the size of the integrated circuit, the accompanied heat generation becomes Yu-Lieh Wu is an assistant professor and Min-Yi Chen is a graduate student of the Department of
11、Refrigeration, Air Conditioning and Energy Engineering, National Chin-Yi University of Technology, Taiping City, Taiwan. Kai-Shing Yang is an assistant professor of the Department of Electro-Optical and Energy Engineering, MingDao University, Chan-ghua, Taiwan. Chi-Chuan Wang is a senior lead resear
12、cher of Energy hence, alternatives such as heat pipes, liquid immersion, jet impingement and sprays, thermoelectrics, and refrigeration (Tru-tassanawin et al. 2006) must be considered. Of the available alternatives, only thermoelectrics and refrigeration can provide a sub-ambient operation that is q
13、uite attractive for high-flux appli-cations. In practice, refrigeration is capable of operating at a high-temperature ambient, yet its coefficient of performance (COP) is well above the present thermoelectrics system. There are also other advantages for exploiting refrigeration cooling (Taut et al.
14、1997), such as maintenance of low junction temperatures while dissipating high heat fluxes, potential increases in micropro-cessor performance at lower operating temperatures, and increased chip reliability. Investigations reported for cooling of electronic devices via refrigeration were mainly rela
15、ted to the fundamental system performance, such as junction to ambient air thermal resistance, system COP of the refrig-eration system (Phelan and Swanson 2004), and transient response behavior (Nnann 2006). Some refrigeration cooling systems for electronics are already available (e.g., see Schmidt
16、and Noto-hardjono 2002, Thermaltake 2009, and Bash et al. 2002). However, as pointed out by Agwu Nnanna (2006), there are two major concerns when using refrigeration systems to cool electronics. The first is associated with the condensation on the sur-faces subject to sub-ambient operation, and the
17、second is the systems lagging response to applied load at the evaporator. Note that condensation takes place when the temperature is below the dew-point temperature of the surrounding air. The presence of water condensate can bring hazards to the electronic system and must be avoided at all times. T
18、ypical solutions may involve clumsy insulation or use an additional heater to vaporize condensate outside the cold plate (Asetek 2009). The former requires considerable space that is often quite limited in prac-tice and is apt to reduce the overall system performance due to blockage of the airflow.
19、The lat-ter design not only raises problems in control but also incurs additional energy consumption. In view of the shortcomings of these two common solutions, the present study offers a novel design to entirely eradicate the influence of condensate. Performance of the proposed concept is then comp
20、ared with the conventional cold plate.NOVEL CONCEPT TO MINIMIZE/ELIMINATE CONDENSATEA refrigeration system normally has four major components, namely a compressor, a con-denser, an expansion device, and an evaporator (a cold plate placed above the heat source for heat removal). For this study, the r
21、efrigeration system includes a variable-speed drive compres-sor, a water-cooled condenser, a metering valve and a capillary tube as the expansion device, and a cold plate as the evaporator. R-134a is used as the working refrigerant. The most crucial design of this concept lies in the process of the
22、pressure-reducing device. During the pressure-reducing process, refrigerant temperature is also reducing. For the conven-tional design, a low temperature well below the ambient temperature is achieved through an expansion device (capillary tube, expansion valve, short tube, and the like), resulting
23、in a surface temperature lower than the corresponding dew-point temperature. Therefore, condensation takes place on the surface if there is no thermal insulation. To tackle this problem, we have proposed a two-stage expansion design that is capable of minimizing or even entirely eliminating the form
24、a-tion of condensate along the cold plate without the help of insulation. The basic principle of this novel idea can be seen from the T-S diagram shown in Figure 1. The idea incorporates the two-stage expansion in the cold plate. For the first stage of expansion, a capillary tube (or expan-sion valv
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASHRAEIJHVAC1612010HVACRRESEARCHHVACR 研究 PDF

链接地址:http://www.mydoc123.com/p-455179.html