ANSI RAC-1-2015 Room Air Conditioners.pdf
《ANSI RAC-1-2015 Room Air Conditioners.pdf》由会员分享,可在线阅读,更多相关《ANSI RAC-1-2015 Room Air Conditioners.pdf(36页珍藏版)》请在麦多课文档分享上搜索。
1、 p 1 AHAM RAC-1-WORKING DRAFT - VERSION 1.0 Room Air Conditioners ANSI/AHAM RAC-1-2015 p i ANSI/AHAM RAC-1-2015 PREFACE The Association of Home Appliance Manufacturers develops standards in accordance with AHAMs “Policy and Procedures Governing Technical Standards“ which states: “AHAM Standards shal
2、l be in the best interest, mutually, of consumers who use appliances, the industries which provide and service appliances, and other interested parties. They shall relate to actual use conditions, be technically and scientifically sound.“ Use or observance of AHAM standards is voluntary. This standa
3、rd contains Test procedures that may be applied to any brand or model of room air conditioner. Results of tests in accordance with this standard may be publicly stated. Recommended levels of performance which are considered important to include but which, necessarily, are recommendations only. AHAM
4、standards are presented to the American National Standards Institute (ANSI) for recognition as American National Standards. This standard was so recognized on May 13, 2015 and bears the American National Standard designation ANSI/AHAM RAC-1-2015. The test results may be compared with AHAMs recommend
5、ed level of performance, if any, for a particular product characteristic. With regard to safety, AHAM recommends that all appliance products-both major and portable-manufactured or marketed in the United States be submitted to an appropriate independent laboratory such as Underwriters Laboratories,
6、Inc., or the American Gas Association Laboratories, Inc., for inspection and listing in conformance with the safety standards and procedures followed by such laboratories. The relevant standards for room air conditioners are UL 484, Room Air Conditioners, and this standard, AHAM RAC-1, Room Air Cond
7、itioners. AHAM welcomes comments and suggestions regarding this standard. Any standard may be reviewed and improved as needed. All standards must be updated or reconfirmed at least every five years. Any interested party, at any time, may request a change in an AHAM standard. Such request should be a
8、ddressed to AHAMs President, and should be accompanied by a statement of reason for the request and a suggested alternate proposal. When metric units are not specified, conversion from customary units should be done in accordance with the American Society of Heating, Refrigerating and Air-Conditioni
9、ng Engineers, Inc. (ASHRAE) Metric Practice Guide, and the AHAM SI Metric Practice Guide for the Appliance Industry. Copyright 2015 by the Association of Home Appliance Manufacturers (AHAM) All rights reserved. The hard copy print version of this document shall be for individual use only. The electr
10、onic file version of this document shall be for storage on one computer for purposes of viewing and/or printing one copy for individual use only. This document shall not be reproduced in whole or in part by any means, and shall not be transmitted electronically or otherwise to a third person without
11、 the prior written permission of AHAM. p ii ANSI/AHAM RAC-1-2015 CONTENTS 1. PURPOSE 1 2. SCOPE . 1 3. DEFINITIONS 1 3.1. Room Air Conditioner . 1 3.2. Cooling Capacity . 1 3.3. Moisture Removal Capacity 1 3.4. Heating Capacity 1 3.5. Recirculated Air . 2 3.6. Ventilating Air . 2 3.7. Exhaust Air 2
12、3.8. Standard Air . 2 3.9. Energy Efficiency Ratio . 2 3.10. Active mode . 2 3.11. Inactive mode . 2 3.12. Off mode 2 3.13. Standby mode 3 3.14. Rounding 3 4. TESTING CONDITIONS 3 4.1. General . 3 4.2. Active Mode 3 4.3. Standby and Off Modes . 4 5. STANDARD MEASUREMENT TEST 5 5.1. Standard Measurem
13、ents . 5 5.2. Standard Test Conditions . 5 5.3. Nameplate 6 6. PERFORMANCE TESTS - COOLING UNITS 6 6.1. Cooling Capacity Test 6 6.2. Electrical Input Test . 6 6.3. Standby and Off Mode Test . 7 6.4. Standby and Off Mode Annual Energy Consumption (ETSO) 7 6.5. Energy Efficiency Ratio (EER) . 8 6.6. A
14、verage Annual Energy Consumption (EAAC) . 8 6.7. Combined Annual Energy Consumption (ECAE) 8 6.8. Combined Energy Efficiency Ratio (CEER) . 8 6.9. Moisture Removal Capacity Test . 8 6.10. Recirculated Air Quantity Test 9 6.11. Ventilating Air Quantity Test and Exhaust Air Quantity Test . 9 6.12. Max
15、imum Operating Conditions Test . 9 6.13. Freeze-Up Tests . 11 6.14. Enclosure Sweat Test . 13 6.15. Condensate Disposal Test. . 14 p iii ANSI/AHAM RAC-1-2015 7. PERFORMANCE TESTS HEATING-COOLING UNITS 15 7.1. Heating-Cooling Units . 15 7.2. Heating Capacity Test 15 7.3. Electrical Input Test . 15 7.
16、4. Application Heating Capacity Test 15 7.5. Maximum Operating Conditions Test . 16 7.6. Outside Coil De-Icing Test 17 8. SAFETY . 18 APPENDIX A 19 APPENDIX B 23 p 1 ANSI/AHAM RAC-1-2015 1. PURPOSE This standard establishes a uniform, repeatable procedure or standard method for measuring specified p
17、roduct characteristics of room air conditioners. The standard methods and the recommended levels of performance, where they appear, are intended to provide a means to compare and evaluate different brands and models of room air conditioners regarding characteristics significant to product use. The s
18、tandard methods and the recommended levels of performance are not intended to preclude the exercise of ingenuity or to prevent improvement and innovation in design and performance. 2. SCOPE This standard establishes standard methods for measuring performance and includes sections on definitions, tes
19、t conditions, tests for standard measurements, performance tests, and safety which apply to room air conditioners as defined in 3.1. Performance tests for Heating-Cooling Units (Section 7) apply to units designed as air-to- air source heat pumps with or without supplementary electric resistance heat
20、. The tests do not apply to units with electric resistance as the only heat source. 3. DEFINITIONS 3.1. Room Air Conditioner A room air conditioner is an encased assembly designed as a unit to be mounted in a window or through a wall, or as a console. It is designed primarily to provide free deliver
21、y of conditioned air to an enclosed space, room or zone. It includes a prime source of refrigeration for cooling and dehumidification and means for circulating and cleaning air, and may also include means for ventilating and heating. A packaged terminal air conditioner, a system designed to accommod
22、ate various components for heating methods (steam, electric, hot water, etc.) is not considered a room air conditioner. 3.2. Cooling Capacity Cooling capacity is a measure of the ability of a unit to remove heat from an enclosed space, room or zone. 3.3. Moisture Removal Capacity Moisture removal ca
23、pacity is a measure of the ability of a unit to remove moisture from an enclosed space, room or zone. 3.4. Heating Capacity Heating capacity is a measure of the ability of a unit to add heat to an enclosed space, room or zone. p 2 ANSI/AHAM RAC-1-2015 3.5. Recirculated Air Recirculated air is the ai
24、r discharged by a unit into an enclosed space, room or zone when all ventilating and exhaust dampers are closed. 3.6. Ventilating Air Ventilating air is the air introduced from outside by a unit into an enclosed space, room or zone. 3.7. Exhaust Air Exhaust air is the air discharged to the outside b
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIRAC12015ROOMAIRCONDITIONERSPDF