ANSI N42.15-1997 Performance Verification of Liquid-Scintillation Counting Systems《液体闪烁计数系统的性能检定》.pdf
《ANSI N42.15-1997 Performance Verification of Liquid-Scintillation Counting Systems《液体闪烁计数系统的性能检定》.pdf》由会员分享,可在线阅读,更多相关《ANSI N42.15-1997 Performance Verification of Liquid-Scintillation Counting Systems《液体闪烁计数系统的性能检定》.pdf(24页珍藏版)》请在麦多课文档分享上搜索。
1、The Institute of Electrical and Electronics Engineers, Inc.345 East 47th Street, New York, NY 10017-2394, USACopyright 1997 by the Institute of Electrical and Electronics Engineers, Inc.All rights reserved. Published 1997. Printed in the United States of America.ISBN 1-55937-970-7No part of this pub
2、lication may be reproduced in any form, in an electronic retrieval system or otherwise, without the prior written permission of the publisher.ANSI N42.15-1997(R2004)American National Standard Check Sources for and Verification of Liquid- Scintillation Counting SystemsSponsorNational Committee on Rad
3、iation Instrumentation, N42Accredited by theAmerican National Standards InstituteSecretariatInstitute of Electrical and Electronics Engineers, Inc.Approved 29 September 1997Reaffirmed 2 December 2004American National Standards InstituteAbstract: Tests and procedures to ensure that a liquid-scintilla
4、tion counting system is producingreliable data are provided for designers and users. This standard does not cover the calculation ofsample activity for quenched unknown samples, sample preparation, efficiency correlation (quenchcorrection) procedures, or identification of unknown radionuclides.Keywo
5、rds: calculation of sample activity, liquid-scintillation counting systems, quenched unknownsamples, tests and procedures for liquid-scintillation counting systemsCopyright The Institute of Electrical and Electronics Engineers, Inc. Provided by IHS under license with IEEENot for ResaleNo reproductio
6、n or networking permitted without license from IHS-,-,-American National StandardAn American National Standard implies a consensus of those substantially concerned with its scopeand provisions. An American National Standard is intended as a guide to aid the manufacturer, theconsumer, and the general
7、 public. The existence of an American National Standard does not in anyrespect preclude anyone, whether he has approved the standard or not, from manufacturing, market-ing, purchasing, or using products, processes, or procedures not conforming to the standard. Amer-ican National Standards are subjec
8、t to periodic reviews and users are cautioned to obtain the latesteditions.CAUTION NOTICE:This American National Standard may be revised or withdrawn at any time.The procedures of the American National Standards Institute require that action be taken to reaf-firm, revise, or withdraw this standard n
9、o later than five years from the date of publication. Purchas-ers of American National Standards may receive current information on all standards by calling orwriting the American National Standards Institute.Authorization to photocopy portions of any individual standard for internal or personal use
10、 isgranted by the Institute of Electrical and Electronics Engineers, Inc., provided that the appropriatefee is paid to Copyright Clearance Center. To arrange for payment of licensing fee, please contactCopyright Clearance Center, Customer Service, 222 Rosewood Drive, Danvers, MA 01923 USA;(508) 750-
11、8400. Permission to photocopy portions of any individual standard for educational class-room use can also be obtained through the Copyright Clearance Center.Copyright The Institute of Electrical and Electronics Engineers, Inc. Provided by IHS under license with IEEENot for ResaleNo reproduction or n
12、etworking permitted without license from IHS-,-,-Copyright 1997 IEEE. All rights reserved.iiiIntroduction(This introduction is not part of ANSI N42.151997, American National Standard Check Sources for and Verification ofLiquid Scintillation Counting Systems.)This standard is the responsibility of th
13、e Accredited Standards Committee N42 on Radiation Instrumenta-tion. Committee N42 delegated the development of this standard to its subcommittee N42.RM. Drafts werereviewed by Committee N42, Subcommittee N42.RM, and other interested parties, and the commentsreceived were utilized in producing the st
14、andard as finally approved.This standard combines ANSI N42.15-1990, American National Standard Verification of Liquid-Scintilla-tion Counting Systems, and ANSI N42.16-1986, American National Standard Specifications for SealedRadioactive Check Sources Used in Liquid-Scintillation Counters, with modif
15、ications. This standard wasapproved by N42 letter ballot on 28 January 1997.At the time it approved this standard, the Accredited Standards Committee on Radiation Instrumentation,N42, had the following members:Louis Costrell,ChairOrganization Represented Name of RepresentativeAmerican Conference of
16、Governmental Industrial HygienistsJesse LiebermanBicron/Harshaw CoJoseph C. BellianEberline Instrument CoJames K. HeschEG used as subscript notation (e.g., ni).n Number of measurements in a series.N Total number of counts accumulated in an individual measurement.R Net count rate in an individual mea
17、surement in counts per minute.t Counting time in minutes.tcElapsed counting time for a short-lived radionuclide expressed in the same units of time as the half-life.l Radioactivity decay constant.S Computed standard deviation of a measured distribution. An estimate of s.s True standard deviation for
18、 the measured distribution.Average of n measurements of N as defined by Equation (1).c2Statistic used to compare the observed variance of a distribution with a hypothetical variance; c2=S2/s2.X2Computed value of c2for a real distribution; see Equation (4).s N4 Copyright 1997 IEEE. All rights reserve
19、d.ANSIVERIFICATION OF LIQUID-SCINTILLATION COUNTING SYSTEMS N42.15-1997Copyright The Institute of Electrical and Electronics Engineers, Inc. Provided by IHS under license with IEEENot for ResaleNo reproduction or networking permitted without license from IHS-,-,-5. MaterialsThe recommendations for t
20、he various sample components are based on the availability of the material andestablished criteria of purity as they relate to assay for radioactivity by liquid-scintillation counting.5.1 SolventAnalytical-grade toluene shall be used as the solvent for all check sources. Toluene shall meet or exceed
21、 thespecifications of B13 for purity and shall be of fossil origin. (As of this writing, all commercially availabletoluene is of fossil origin.) Requirements for toluene acceptance are listed in Annex E.5.2 Organic-scintillator solutesA primary scintillator, 2,5-diphenyloxazole (PPO), shall be used
22、in preparing check sources. The physicalproperties of this compound are listed in Annex A. One of the following secondary scintillators may beincluded in preparing check sources:a) 1,4-bis-2-(5-phenyloxazolyl)-benzeneb) 1,4-bis-2-(4-methyl-5-phenyloxazolyl)-benzenec) p-bis-(O-methylstyryl)-benzeneTh
23、eir physical properties are listed in Annexes B, C, and D, respectively. 5.3 Radioactive materialTritium-labeled and carbon-14-labeled toluene shall be used as radioactivity standard material.5.4 Sample containerThe sample container shall conform to IEC 60582 (1977-01) for Type II glass vials, excep
24、t for the overallheight, which shall not exceed the specified maximum. For small-vial counting systems, see 8.3. The glassshall be low-potassium, borosilicate glass. The sample shall be contained within the cylindrical portion ofthe vial.5.5 Purging gasThe purging gas shall be any inert gas such as
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIN42151997PERFORMANCEVERIFICATIONOFLIQUIDSCINTILLATIONCOUNTINGSYSTEMS 液体 闪烁 计数 系统 性能 检定 PDF

链接地址:http://www.mydoc123.com/p-437402.html