ANSI ATIS 0600015.13-2017 Energy Efficiency for Telecommunication Equipment Methodology for Measurement and Reporting of 802.11xx Wi-Fi Access Points.pdf
《ANSI ATIS 0600015.13-2017 Energy Efficiency for Telecommunication Equipment Methodology for Measurement and Reporting of 802.11xx Wi-Fi Access Points.pdf》由会员分享,可在线阅读,更多相关《ANSI ATIS 0600015.13-2017 Energy Efficiency for Telecommunication Equipment Methodology for Measurement and Reporting of 802.11xx Wi-Fi Access Points.pdf(16页珍藏版)》请在麦多课文档分享上搜索。
1、 ATIS-0600015.13.2017 American National Standard for Telecommunications Energy Efficiency for Telecommunication Equipment: Methodology for Measurement and Reporting of 802.11xx Wi-Fi Access Points Alliance for Telecommunications Industry Solutions Approved January 2017 Abstract This document specifi
2、es the definition of Wi-Fi Access Points based on a network they served, as well as a methodology to calculate the Telecommunication Energy Efficiency Ratio (TEER). The standard will also provide requirements for how equipment vendors shall respond to a TEER request based on a specific application d
3、escription by making use of relevant data from internal and independent test reports. ATIS-0600015.13.2017 ii Foreword The information contained in this Foreword is not part of this American National Standard (ANS) and has not been processed in accordance with ANSIs requirements for an ANS. As such,
4、 this Foreword may contain material that has not been subjected to public review or a consensus process. In addition, it does not contain requirements necessary for conformance to the Standard. The Alliance for Telecommunication Industry Solutions (ATIS) serves the public through improved understand
5、ing between providers, customers, and manufacturers. The Sustainability in Telecom: Energy and Protection (STEP) Committee formerly the Network Interface, Power, and Protection (NIPP) Committee engages industry expertise to develop standards and technical reports for telecommunications equipment and
6、 environments in the areas of energy efficiency, environmental impacts, power, and protection. The work products of STEP enable vendors, operators, and their customers to deploy and operate reliable, environmentally sustainable, energy efficient communications technologies. STEP is committed to proa
7、ctive engagement with national, regional, and international standards development organizations and forums that share its scope of work. ANSI guidelines specify two categories of requirements: mandatory and recommendation. The mandatory requirements are designated by the word shall and recommendatio
8、ns by the word should. Where both a mandatory requirement and a recommendation are specified for the same criterion, the recommendation represents a goal currently identifiable as having distinct compatibility or performance advantages. Suggestions for improvement of this document are welcomed. They
9、 should be sent to the Alliance for Telecommunications Industry Solutions, STEP, 1200 G Street NW, Suite 500, Washington, DC 20005. At the time it approved this document, STEP, which was responsible for its development, had the following roster: K. Biholar STEP Chair (Nokia) J. Krahner, STEP Vice Ch
10、air (Cisco) L. Rabinovich, STEP TEE Chair (Cisco) S. Martin, STEP TEE Vice Chair (AT see Informative References A.1. The same as physical layer bit rate. Line Data Rate: The maximum user data rate AP is capable of passing from wired port to wireless user. Active mode: All ports (frequencies) connect
11、ed to N clients, with user data traffic. AP Utilization in %: Aggregated data traffic for all radio transmitters equally distributed between N clients divided by Line Rate and multiplied by 100%. Idle mode: The same as Active mode, but with no user data traffic (it is not zero traffic as service and
12、 protocol supporting traffic is present). Not been used, but ready. Typical utilization: 10% of Line Rate. Client: A device that connects to a Wi-Fi AP. Multiple Input, Multiple Output (MIMO): A physical layer configuration in which both transmitter and receiver use multiple antennas. Multi-User MIM
13、O (MU-MIMO): A technique by which an AP transmits a Physical Layer Convergence Procedure (PLCP) Protocol Data Unit (PDU) to multiple receiving non-AP stations (STAs). QAM: Quadrature Amplitude Modulation Spatial Multiplexing (SM): A transmission technique in which data streams are transmitted on mul
14、tiple spatial channels that are provided through the use of multiple antennas at the transmitter and the receiver. Spatial Stream: One of several streams of bits or modulation symbols that might be transmitted over multiple spatial dimensions that are created by the use of multiple antennas at both
15、ends of a communications link. 3.2 Acronyms for 802.3at devices, Rs is 12.5 ohms. Test Procedure: 1. Connect PD under test to test equipment as shown in Figure B.1. 2. Rs shall be 0-Ohm. 3. Measure the average power per IEEE 802.3af/at for 15 minutes with readings at least every second. Figure B.1 r
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIATIS0600015132017ENERGYEFFICIENCYFORTELECOMMUNICATIONEQUIPMENTMETHODOLOGYFORMEASUREMENTANDREPORTINGOF80211XXWIFIACCESSPOINTSPDF

链接地址:http://www.mydoc123.com/p-433463.html